Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring

Digiglio, Philip, Li, Ruya, Wang, Wenqi, Pan, Tingrui·2014·Annals of Biomedical Engineering

Abstract

Personalized mobile medicine will continue to advance through the development of wearable sensors that can wirelessly provide pertinent health information while remaining unobtrusive, comfortable, low cost, and easy to operate and interpret. It is the intention that the sensor presented hereafter can contribute to such innovation. By applying a combination of emerging microfluidic and electronic technologies, a miniature, flexible, transparent, highly sensitive and wearable pressure sensor with microfluidic elements has been implemented, referred to as a microflotronic device. High sensitivity of 0.1 kPa(-1) and fast response time on the order of tens of milliseconds has been achieved on the microflotronic sensor design. Its sensitivity is among the highest in impedance-based flexible pressure sensors. Once configured into an array, the transparent device can be easily aligned over the target artery to measure blood pressure noninvasively and continuously. In addition, the ultraflexible and thin plastic construct of the microflotronic sensor (of 270 µm in height) can be worn comfortably for extended periods of time. Importantly, the proposed microflotronic sensor has been utilized to perform arterial tonometry with the capability of noninvasive monitoring of arterial blood pressure waveforms in a real-time and continuous fashion.

Integrity signals

Registry

Crossref · 10.1007/s10439-014-1037-1

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Digiglio, P., Li, R., Wang, W., & Pan, T.
Affiliations
  • University of California, Davis (US)
  • University of California System (US)
Corresponding author
Pan, Tingrui
Venue
Annals of Biomedical Engineering
Published
2014-06-03
Volume
42
Issue
11
Pages
2278-2288
ISSN
  • 0090-6964 (ISSN-L)
  • 1573-9686
OpenAlex
W1995985276
Cited by
38
References
35
Citations by year
2026: 1 · 2025: 3 · 2024: 6 · 2023: 2 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 2 · 2014: 1
FWCI
1.56
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation
  • China Scholarship Council
  • Division of Electrical, Communications and Cyber Systems
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
wearable pressure sensors, arterial tonometry, non-invasive blood pressure monitoring, flexible transparent electronics, arterial pressure waveform, continuous hemodynamic monitoring, wearable health monitoring
MeSH terms
Adult, Equipment Design, Hemodynamics, Humans, Manometry, Monitoring, Physiologic, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review