CoChat

Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge

Open access
Steinman, David A., Hoi, Yiemeng, Fahy, Paul, Morris, Liam, Walsh, Michael T., Aristokleous, Nicolas, Anayiotos, Andreas S., Papaharilaou, Yannis, Arzani, Amirhossein, Shadden, Shawn C., Berg, Philipp, Janiga, Gábor, Bols, Joris, Segers, Patrick, Bressloff, Neil W., Cibis, Merih, Gijsen, Frank H., Cito, Salvatore, Pallarés, Jordi, Browne, Leonard D., Costelloe, Jennifer A., Lynch, Adrian G., Degroote, Joris, Vierendeels, Jan, Fu, Wenyu, Qiao, Aike, Hodis, Simona, Kallmes, David F., Kalsi, Hardeep, Long, Quan, Kheyfets, Vitaly O., Finol, Ender A., Kono, Kenichi, Malek, Adel M., Lauric, Alexandra, Menon, Prahlad G., Pekkan, Kerem, Esmaily Moghadam, Mahdi, Marsden, Alison L., Oshima, Marie, Katagiri, Kengo, Peiffer, Véronique, Mohamied, Yumnah, Sherwin, Spencer J., Schaller, Jens, Goubergrits, Leonid, Usera, Gabriel, Mendina, Mariana, Valen-Sendstad, Kristian, Habets, Damiaan F., Xiang, Jianping, Meng, Hui, Yu, Yue, Karniadakis, George E., Shaffer, Nicholas, Loth, Francis · 2013 · Journal of Biomechanical Engineering
Cited by 141

The DOI matches its Crossref record.

Abstract

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.4023382

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 141

Metadata

Authors
Steinman, D. A., Hoi, Y., Fahy, P., Morris, L., Walsh, M. T., Aristokleous, N., Anayiotos, A. S., Papaharilaou, Y., Arzani, A., Shadden, S. C., Berg, P., Janiga, G., Bols, J., Segers, P., Bressloff, N. W., Cibis, M., Gijsen, F. H., Cito, S., Pallarés, J., Browne, L. D., Costelloe, J. A., Lynch, A. G., Degroote, J., Vierendeels, J., Fu, W., Qiao, A., Hodis, S., Kallmes, D. F., Kalsi, H., Long, Q., Kheyfets, V. O., Finol, E. A., Kono, K., Malek, A. M., Lauric, A., Menon, P. G., Pekkan, K., Esmaily Moghadam, M., Marsden, A. L., Oshima, M., Katagiri, K., Peiffer, V., Mohamied, Y., Sherwin, S. J., Schaller, J., Goubergrits, L., Usera, G., Mendina, M., Valen-Sendstad, K., Habets, D. F., Xiang, J., Meng, H., Yu, Y., Karniadakis, G. E., Shaffer, N., & Loth, F.
Venue
Journal of Biomechanical Engineering
Published
2013-02-01
Volume
135
Issue
2
Pages
021016-021016
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2070231051
Cited by
141
References
0
FWCI
8.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge. https://app.cochat.ai/papers/10.1115/1.4023382
The paper
Steinman, D. A., Hoi, Y., Fahy, P., Morris, L., Walsh, M. T., Aristokleous, N., Anayiotos, A. S., Papaharilaou, Y., Arzani, A., Shadden, S. C., Berg, P., Janiga, G., Bols, J., Segers, P., Bressloff, N. W., Cibis, M., Gijsen, F. H., Cito, S., Pallarés, J., . . . Loth, F. (2013). Variability of Computational Fluid Dynamics Solutions for Pressure and Flow in a Giant Aneurysm: The ASME 2012 Summer Bioengineering Conference CFD Challenge. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4023382

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.