The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
High-Intensity Focused Ultrasound: A Review of Mechanisms and Clinical Applications
Open accessAbstract
High Intensity Focused Ultrasound (HIFU) is an emerging and increasingly useful modality in the treatment of cancer and other diseases. Although traditional use of ultrasound at lower frequencies has primarily been for diagnostic imaging purposes, the development of HIFU has allowed this particular modality to expand into therapeutic use. This non-invasive and acoustic method involves the use of a piezoelectric transducer to deliver high-energy pulses in a spatially coordinated manner, while minimizing damage to tissue outside the target area. This review describes the history of the development of diagnostic and therapeutic ultrasound and explores the biomedical applications utilizing HIFU technology including thermally ablative treatment, therapeutic delivery mechanisms, and neuromodulatory phenomena. The application of HIFU across various tumor types in multiple organ systems is explored in depth, with particular attention to successful models of HIFU in the treatment of various medical conditions. Basic mechanisms, preclinical models, previous clinical use, and ongoing clinical trials are comparatively discussed. Recent advances in HIFU across multiple medical fields reveal the growing importance of this biomedical technology for the care of patients and for the development of possible pathways for the future use of HIFU as a commonplace treatment modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2020) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21590 · Cited by 20,444
Santos, A. G., da Rocha, G. O., & de Andrade, J. B. (2019) · Scientific Reports · doi:10.1038/s41598-018-37186-2 · Cited by 8,495
Epidemiology of Prostate Cancer
Rawla, P. (2019) · World Journal of Oncology · doi:10.14740/wjon1191 · Cited by 2,776
Colloca, L., Ludman, T., Bouhassira, D., Baron, R., Dickenson, A. H., Yarnitsky, D., Freeman, R., Truini, A., Attal, N., Finnerup, N. B., et al. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.2 · Cited by 2,058
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805
A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY
Lynn, J. G., Zwemer, R. L., Chick, A. J., & Miller, A. E. (1942) · Journal of General Physiology · doi:10.1085/jgp.26.2.179 · Cited by 690
High intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
Mainprize, T., Lipsman, N., Huang, Y., Meng, Y., Bethune, A., Ironside, S., Heyn, C., Alkins, R., Trudeau, M., Sahgal, A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-36340-0 · Cited by 618
Breast Cancer Epidemiology and Risk Factors
ROJAS, K., & STUCKEY, A. (2016) · Clinical Obstetrics & Gynecology · doi:10.1097/grf.0000000000000239 · Cited by 576
Khan, K., Tareen, A. K., Aslam, M., Ali Khan, S., khan, Q., Khan, Q. U., Saeed, M., Siddique Saleemi, A., Kiani, M., Ouyang, Z., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-55207-6 · Cited by 518
Metadata
- Authors
- Bachu, V. S., Kedda, J., Suk, I., Green, J. J., & Tyler, B.
- Venue
- Annals of Biomedical Engineering
- Published
- 2021-08-10
- Volume
- 49
- Issue
- 9
- Pages
- 1975-1991
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W3187668469
- Cited by
- 297
- References
- 63
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Intensity Focused Ultrasound: A Review of Mechanisms and Clinical Applications. https://app.cochat.ai/papers/10.1007/s10439-021-02833-9
- The paper
- Bachu, V. S., Kedda, J., Suk, I., Green, J. J., & Tyler, B. (2021). High-Intensity Focused Ultrasound: A Review of Mechanisms and Clinical Applications. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-021-02833-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.