In vitro analysis of a hepatic device with intrinsic microvascular-based channels
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A novel microfluidics-based bilayer device with a discrete parenchymal chamber modeled upon hepatic organ architecture is described. The microfluidics network was designed using computational models to provide appropriate flow behavior based on physiological data from human microvasculature. Patterned silicon wafer molds were used to generate films with the vascular-based microfluidics network design and parenchymal chamber by soft lithography. The assembled device harbors hepatocytes behind a nanoporous membrane that permits transport of metabolites and small proteins while protecting them from the effects of shear stress. The device can sustain both human hepatoma cells and primary rat hepatocytes by continuous in vitro perfusion of medium, allowing proliferation and maintaining hepatic functions such as serum protein synthesis and metabolism. The design and fabrication processes are scalable, enabling the device concept to serve as both a platform technology for drug discovery and toxicity, and for the continuing development of an improved liver-assist device.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“transferrin (0.1-17.2 pg/cell/day) [65,67,68]”
From A liver-on-a-chip platform with bioprinted hepatic spheroids (2016) · cites this paper as [67]
Citations
Cites
Chapter 4 Preparation of Isolated Rat Liver Cells
Seglen, P. O. (1976) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)61797-5 · Cited by 5,310
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Current Protocols in Protein Science
(2018) · Current Protocols in Protein Science · doi:10.1002/(issn)1934-3663 · Cited by 1,189
The Human Hepatic Cytochromes P450 Involved in Drug Metabolism
Wrighton, S. A., & Stevens, J. C. (1992) · Critical Reviews in Toxicology · doi:10.3109/10408449209145319 · Cited by 944
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Microfabrication Technology for Vascularized Tissue Engineering
Borenstein, J. T., Terai, H., King, K. R., Weinberg, E. J., Kaazempur-Mofrad, M. R., & Vacanti, J. P. (2002) · Biomedical Microdevices · doi:10.1023/a:1016040212127 · Cited by 361
Self-citationEngineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Advances in bioartificial liver devices
Allen, J. W., Hassanein, T., & Bhatia, S. N. (2001) · Hepatology · doi:10.1053/jhep.2001.26753 · Cited by 326
Research works printed but not linked: 2
- M.F. Kiani, A.R. Pries, L.L. Hsu, I.H. Sarelius, G.R. Cokelet, Am. J. Physiol. 266(5 Pt 2), H1822–H1828 (1994)
- A.R. Pries, D. Neuhaus, P. Gaehtgens, Am. J. Physiol. 263(6 Pt 2), H1770–H1778 (1992)
Cited by
Items 101–172 of 172
Integrated Microphysiological Systems: Transferable Organ Models and Recirculating Flow
Renggli, K., Rousset, N., Lohasz, C., Nguyen, O. T. P., & Hierlemann, A. R. (2019) · Advanced Biosystems · doi:10.1002/adbi.201900018 · Cited by 22
Engineering Tissue with BioMEMS
Borenstein, J. T., & Vunjak‐Novakovic, G. (2011) · IEEE Pulse · doi:10.1109/mpul.2011.942764 · Cited by 23
“Microfluidic PDMS constructs have been reported by Leclerc [19], while a membrane bilayer system has been shown to replicate liver function by Carraro [20].”
MethodSelf-citationApplication of microtechnologies for the vascularization of engineered tissues
Gauvin, R., Guillemette, M. D., Dokmeci, M. R., & Khademhosseini, A. (2011) · Vascular Cell · doi:10.1186/2045-824x-3-24 · Cited by 19
“Few attempts were made to engineer perfused microfluidic devices in which two different cell types can be cultured [36,46], but a vascularized tissue with parenchymal cells has yet to be created and there are still no methods to build sustainable large cell-laden structures with multi-dimensional branched networks.”
Micro- and Nanotechnology in Tissue Engineering
Coutinho, D. F., Costa, P. F., Neves, N. M., Gomes, M. E., & Reis, R. L. (2010) · Springer eBooks · doi:10.1007/978-3-642-02824-3_1 · Cited by 20
Engineering of Implantable Liver Tissues
Sakai, Y., Nishikawa, M., Evenou, F., Hamon, M., Huang, H., Montagne, K., Kojima, N., Fujii, T., & Niino, T. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-468-1_16 · Cited by 16
Nanomaterial Toxicity: Emerging Standards and Efforts to Support Standards Development
Locascio, L. E., Reipa, V., Zook, J. M., & Pleus, R. C. (2011) · Nanostructure science and technology · doi:10.1007/978-1-4419-7853-0_8 · Cited by 15
Shan, J., Stevens, K. R., Trehan, K., Underhill, G. H., Chen, A. A., & Bhatia, S. N. (2010) · Molecular pathology library · doi:10.1007/978-1-4419-7107-4_22 · Cited by 18
“(Figure panels reproduced with permission from [82].”
Fabrication of 3D Microstructures from Interactions of Immiscible Liquids with a Structured Surface
Balowski, J., Wang, Y., & Allbritton, N. L. (2013) · Advanced Materials · doi:10.1002/adma.201301658 · Cited by 13
Garziano, A., Urciuolo, F., Imparato, G., Martorina, F., Corrado, B., & Netti, P. A. (2016) · Lab on a Chip · doi:10.1039/c5lc01481f · Cited by 13
NANO/MICROSCALE TECHNOLOGIES FOR DRUG DELIVERY
Li, H., Kochhar, J. S., PAN, J., Chan, S. Y., & Kang, L. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941100406x · Cited by 13
Cell Microarrays for Biomedical Applications
Rothbauer, M., Charwat, V., & Ertl, P. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-3136-1_19 · Cited by 12
Validation of Bioreactor and Human-on-a-Chip Devices for Chemical Safety Assessment
Rebelo, S. P., Dehne, E., Brito, C., Horland, R., Alves, P. M., & Marx, U. (2016) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-33826-2_12 · Cited by 12
Stevens, K. R., Schwartz, R. E., Ng, S., Shan, J., & Bhatia, S. N. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398358-9.00046-x · Cited by 14
“(Figure panels reproduced with permission from [82].”
Zhu, H., Özkayar, G., Lötters, J. C., Tichem, M., & Ghatkesar, M. K. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00657-z · Cited by 11
Fabrication of free standing microporous COC membranes optimized for in vitro barrier tissue models
Gel, M., Kandasamy, S., Cartledge, K., & Haylock, D. N. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.10.018 · Cited by 10
Microphysiological models of human organs: A case study on microengineered lung-on-a-chip systems
Seo, J., & Huh, D. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00007-4 · Cited by 11
A microphysiological systems approach to design gastrointestinal system
Mathur, V., Gadre, M. A., Amrutha, H. K., & Vasanthan, K. S. (2025) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.2025.2532567 · Cited by 8
Liu, Z., Zhang, W., & Pang, S. W. (2020) · Bioscience Reports · doi:10.1042/bsr20194113 · Cited by 9
Tourlomousis, F., & Chang, R. C. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25822 · Cited by 8
“Moreover, static cell culture formats lack requisite in vivo fluid mechanical shear stress cues (Carraro et al., 2008; Griep et al., 2013).”
BackgroundKakabadze, A., Karalashvili, L., Makashvili, M., Abiatari, I., & Kakabadze, Z. (2014) · Asian Journal of Pharmacy Nursing and Medical Sciences · doi:10.24203/ajpnms.v2i1.911.g506 · Cited by 9
COMPUTATIONAL FLUID DYNAMICS FOR TISSUE ENGINEERING APPLICATIONS
He, J., Li, D., Liu, Y., Li, X., Xu, S., & Lu, B. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004046 · Cited by 10
On-chip immune cell activation and subsequent time-resolved magnetic bead-based cytokine detection
Kongsuphol, P., Liu, Y., & Ramadan, Q. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0117-4 · Cited by 8
A comprehensive overview of advanced dynamic in vitro intestinal and hepatic cell culture models
Leal, F., Zeiringer, S., Jeitler, R., Costa, P. F., & Roblegg, E. (2023) · Tissue Barriers · doi:10.1080/21688370.2022.2163820 · Cited by 11
“114,117,118,129,132,134,135,144,145 HepG2 and HUVECs were cultured under dynamic conditions in the microfluidic device of Mi et al .”
MethodFreeform embedded printing of vasculature in cementitious materials for healing-agent transport
Zhang, Y., Pan, P., Li, W., Dong, B., Tang, J., Xing, F., & Zhu, G. M. (2022) · Additive manufacturing · doi:10.1016/j.addma.2022.103140 · Cited by 12
Antypas, H., Zhang, T., Choong, F. X., Melican, K., & Richter‐Dahlfors, A. (2023) · FEMS Microbes · doi:10.1093/femsmc/xtad007 · Cited by 7
“There are several organ-on-chip models mimicking the liver (Sivaraman et al. 2005, Carraro et al. 2008, Novik et al. 2010), kidney (Baudoin et al. 2007, Snouber et al. 2011, Jang et al. 2013), lung (Huh et al. 2010, 2012), and intestine (Kim et al. 2012, Kim and Ingber 2013).”
BackgroundCells and Organs on a Chip in Biomedical Sciences
Roberts, A., Mahari, S., & Gandhi, S. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_10 · Cited by 5
Menezes, P. D., Hecht, S., Hunter, A., & Gadegaard, N. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.148189 · Cited by 5
“At the same time the porous membrane ( PM ) acts as an artificial in vitro endothelial barrier [66], confining convective transport to perfused channels, whilst enabling diffusive transport between compartments and providing mechanical support for cell growth.”
Maeng, J.-H., Jeong, H. E., Shin, H.-J., Kim, S., Lee, J.-C., Lee, J., Chung, S. H., & Lee, S. (2015) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1602-4 · Cited by 5
“Novel cell compartment designs such as permeable internal membrane (Carraro et al. 2008; Liu and Tai 2010), ‘C’-shape ring (Hung et al.”
BackgroundA revolutionary breakthrough of bionanomaterials in tissue engineering and regenerative medicine
Shankar, P., Jagtap, J. M. M., Sharma, G., Sharma, G. P., Singh, J., Parashar, M., Kumar, G., Mittal, S., Sharma, M. K., Jadhav, K., et al. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823915-5.00001-0 · Cited by 6
Uygun, B. E., Uygun, K., & Yarmush, M. L. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00193-8 · Cited by 5
Design and development of organ on chip using microfluidic technology for simulation
Sarasu, S., & Rama, K. (2013) · International Conference on Optical Imaging Sensor and Security (ICOSS) · doi:10.1109/icoiss.2013.6678412 · Cited by 5
Emerging Trends in Tissue Engineering
Gauvin, R., Khademhosseini, A., Guillemette, M. D., & Langer, R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-088504-9.00534-1 · Cited by 8
Sugiura, S., Satoh, T., Shin, K., Onuki-Nagasaki, R., & Kanamori, T. (2022) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2022.07.001 · Cited by 5
BioMEMS Technologies for Regenerative Medicine
Borenstein, J. T. (2008) · MRS Proceedings · doi:10.1557/proc-1139-gg02-01 · Cited by 7
Self-citationElastic Averaging for Assembly of Three-Dimensional Constructs From Elastomeric Micromolded Layers
Marentis, T. C., Vacanti, J. P., Hsiao, J. C., & Borenstein, J. T. (2009) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2018372 · Cited by 4
“They can function as cell-based, biocompatible extracorporeal assist devices for liver function [12].”
BackgroundSelf-citationGel, M., Kandasamy, S., Cartledge, K., & Haylock, D. N. (2013) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2013.6474388 · Cited by 4
“Polycarbonate membranes have been used to characterize hepatocytes under the influence of a microfluidic channel network with a design similar to hepatic vascular system [9].”
MethodRecent Development of Cell Analysis on Microfludics
He, Z., & Lin, J. (2017) · Integrated analytical systems · doi:10.1007/978-981-10-5394-8_2 · Cited by 4
“Various tissue/organ-on-chip models have been developed, such as blood vessels [78, 79], brain [80], liver [81, 82], lung [83, 84], kidney [85, 86], heart [87, 88], bone [89] and muscle [90].”
BackgroundPhysiologically relevant microsystems to study viral infection in the human liver
McDuffie, D., Barr, D., Agarwal, A., & Thomas, E. (2022) · Frontiers in Microbiology · doi:10.3389/fmicb.2022.999366 · Cited by 4
“…boundary that can separate different cell types or selectively regulate flow across cells in order to modulate nutrient transport (Lee et al., 2007; Carraro et al., 2008; Zhang et al., 2008; Illa et al., 2014; Maher et al., 2014; Rennert et al., 2015; Prodanov et al., 2016; Ylva et al., 2016;…”
BackgroundCOMPUTATIONAL FLUID DYNAMIC ANALYSIS OF A CELL-BASED MICROFLUIDIC DRUG SCREENING PLATFORM
Maguire, T. J., Usta, O. B., & Yarmush, M. L. (2010) · Nano LIFE · doi:10.1142/s1793984410000201 · Cited by 3
Alternatives to animal testing: concepts, state of art, and regulations
Athira, R. K., Kripamol, R., Anju, M. S., Maya, B., Pai, R. R., Ajit, S., Aswathy, M. R., Anil Kumar, P. R., & Kasoju, N. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823966-7.00001-3 · Cited by 5
Organs-on-a-Chip: Principles and Applications
Lombello, C. B., Rezende, L. R., Martins, A. F., & Lameu, J. (2023) · Springer eBooks · doi:10.1007/978-3-031-38743-2_15 · Cited by 3
Sullivan, D. C., Repper, J., Frock, A. W., McFetridge, P. S., & Petersen, B. E. (2015) · Current Pathobiology Reports · doi:10.1007/s40139-015-0066-2 · Cited by 3
Microchip Technology in Metabolomics
Sikanen, T. M. (2013) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737272-00138 · Cited by 3
Ha, L., Jang, K., & Suh, K. Y. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737593-00019 · Cited by 3
Microvascular Networks for Tissue Engineering
Huang, J., Jayaraman, A., & Ugaz, V. M. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-3459-1.00002-8 · Cited by 2
Organs-on-a-Chip in Preclinical Studies
Parvatam, S., & Chavali, P. L. (2022) · Springer eBooks · doi:10.1007/978-981-19-1379-2_23 · Cited by 2
Yao, T., Zhang, Y., Lv, M., Zang, G., Ng, S. S., & Chen, X. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1911.08231 · Cited by 3
“10 Liver sinusoidal endothelial cells [53, 54].”
Transport Models for Three-Dimensional Cell Culture Systems
Inamdar, N. K., Griffith, L. G., & Borenstein, J. T. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-3459-1.00006-5 · Cited by 1
Self-citationMultilayer Microfluidic Poly(Ethylene Glycol) Diacrylate Hydrogels
Cuchiara, M. P., & West, J. L. (2012) · Methods in molecular biology · doi:10.1007/978-1-62703-134-9_24 · Cited by 2
Generation and Application of 3D Culture Systems in Human Drug Discovery and Medicine
Rashidi, H., & Hay, D. C. (2016) · Wiley eBooks · doi:10.1002/9781119135449.ch14 · Cited by 1
Mack, P. J., Khalil, A. S., Weinberg, E. J., Adamo, L., Slegtenhorst, B. R., Borenstein, J. T., & García‐Cardeña, G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00010-4 · Cited by 1
Self-citationPluripotent stem cell biology and engineering
Cotovio, J. P., Fernandes, T. G., Diogo, M. M., & Cabral, J. M. S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816221-7.00001-x · Cited by 2
Fabrication of cell culture microdevices for tissue engineering applications
Cuiffi, J. D. (2012) · Elsevier eBooks · doi:10.1533/9780857096272.3.173 · Cited by 1
Rodent Model for Orthotopic Implantation of Engineered Liver Devices
Sahakyants, T., Lieberthal, T. J., Comer, C. D., HANCOCK, M. J., Spann, A. P., Neville, C. M., & Vacanti, J. P. (2022) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2022.0174 · Cited by 1
Self-citationRecent Advancement of Nanotechnology in Bio Applications
Abedin, A., Mora, J. M., Azad, A., Bhattar, S., Islam, S. M. R., & Hasan, M. H. (2023) · Springer eBooks · doi:10.1007/978-3-031-39404-1_2 · Cited by 2
Transport Model for Microfluidic Device for Cell Culture and Tissue Development
Inamdar, N. K., Griffith, L. G., & Borenstein, J. T. (2011) · MRS Proceedings · doi:10.1557/opl.2011.467 · Cited by 1
Self-citationEpshteyn, A. A. (2010) · Digital Commons - University of South Florida (University of South Florida)
Gel, M., Kandasamy, S., Cartledge, K., Be, C. L., & Haylock, D. N. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2033653
“Polycarbonate (PC) membranes have been used to characterize hepatocytes under the influence of a microfluidic channel network with a design similar to the hepatic vascular system [9].”
MethodAnalysis and implementation of the bilayer microfluidic geometry
Inamdar, N. K. (2011) · DSpace@MIT (Massachusetts Institute of Technology)
Process engineering of liver cells for drug testing applications
Tostões, R. M. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Cuchiara, M. P. (2011) · Rice Research Repository (Rice University)
Engineered In Vitro Systems of the Microcirculation
Moya, M. L., Hughes, C. C. W., & George, S. C. (2014) · CRC Press eBooks · doi:10.1201/b16777-11
Three-dimensional Cardiac Microtissues in a Microfluidic Device : Heart-on-a-chip
Bhullar, I. S. (2015) · eScholarship (California Digital Library)
Développement d'un réseau microvasculaire sur puce microfluidique pour la reconstruction tissulaire
Krammer, T. (2019) · theses.fr (ABES) · doi:10.70675/97039148z56f3z4e12z976azd7199b5b5653
Gastrointestinal organoid structure and transport
Sidar, B. (2019) · Montana State University ScholarWorks (Montana State University)
Nanotechnology in tissue engineering for diabetes management
Behera, A., Mohanty, B., Behera, S., Pradhan, A., Kahnar, S., & Giri, Y. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-95134-0.00018-3
Bricks, T. (2014) · theses.fr (ABES) · doi:10.70675/8b715022z753bz445az91aaze9b8bd1746c2 · Cited by 3
Modèles de vaisseaux sanguins sur puce pour l'étude des fonctions de la barrière endothéliale
Delannoy, E. (2021) · theses.fr (ABES) · doi:10.70675/c1aab157zdfc1z4179z9306zc6f4d4ffcd6f
Development of a biomimetic multitube system in the case of the ADPKD
Myram, S. (2020) · theses.fr (ABES) · doi:10.70675/c98f29bbz7d68z445az955dz1e062d759a8f
Bhalerao, G. V. (2026) · International Conference on Emerging and Intelligent Technologies and Systems (EITS) · doi:10.1109/eits70066.2026.11609599
“The liver-on-a-chip models developed by Carraro and co-workers [21] and by Rennert and colleagues [22] established the importance of perfusion for maintaining hepatic function.”
Microfabrication techniques for making organ-on-a-chip and body-on-a-chip devices
Azizgolshani, H., & Borenstein, J. T. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00021-2
Self-citation
Metadata
- Authors
- Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., & Neville, C.
- Affiliations
- University of Padua (IT)
- Massachusetts General Hospital (US)
- Harvard University (US)
- Draper Laboratory (US)
- Corresponding author
- Neville, Craig
- Venue
- Biomedical Microdevices
- Published
- 2008-07-05
- Volume
- 10
- Issue
- 6
- Pages
- 795-805
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2031785809
- Cited by
- 168
- References
- 23
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 9 · 2022: 11 · 2021: 8 · 2020: 4 · 2019: 7 · 2018: 7 · 2017: 5 · 2016: 14 · 2015: 8 · 2014: 13 · 2013: 19 · 2012: 11
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- bilayer devices, soft lithography, nanoporous membranes, hepatocyte culture, hepatoma cells, primary rat hepatocytes, serum protein synthesis, drug discovery, toxicity testing, artificial liver support
- MeSH terms
- Animals, Drug Evaluation, Preclinical, Humans, Male, Membranes, Artificial, Rats, Inbred Lew, Silicon, Porosity, Cell Culture Techniques, Liver, Artificial, Hepatocytes, Cell Line, Tumor, Microfluidic Analytical Techniques, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.