In vitro analysis of a hepatic device with intrinsic microvascular-based channels
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A novel microfluidics-based bilayer device with a discrete parenchymal chamber modeled upon hepatic organ architecture is described. The microfluidics network was designed using computational models to provide appropriate flow behavior based on physiological data from human microvasculature. Patterned silicon wafer molds were used to generate films with the vascular-based microfluidics network design and parenchymal chamber by soft lithography. The assembled device harbors hepatocytes behind a nanoporous membrane that permits transport of metabolites and small proteins while protecting them from the effects of shear stress. The device can sustain both human hepatoma cells and primary rat hepatocytes by continuous in vitro perfusion of medium, allowing proliferation and maintaining hepatic functions such as serum protein synthesis and metabolism. The design and fabrication processes are scalable, enabling the device concept to serve as both a platform technology for drug discovery and toxicity, and for the continuing development of an improved liver-assist device.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“transferrin (0.1-17.2 pg/cell/day) [65,67,68]”
From A liver-on-a-chip platform with bioprinted hepatic spheroids (2016) · cites this paper as [67]
Citations
Cites
Chapter 4 Preparation of Isolated Rat Liver Cells
Seglen, P. O. (1976) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)61797-5 · Cited by 5,310
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Current Protocols in Protein Science
(2018) · Current Protocols in Protein Science · doi:10.1002/(issn)1934-3663 · Cited by 1,189
The Human Hepatic Cytochromes P450 Involved in Drug Metabolism
Wrighton, S. A., & Stevens, J. C. (1992) · Critical Reviews in Toxicology · doi:10.3109/10408449209145319 · Cited by 944
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Lee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Microfabrication Technology for Vascularized Tissue Engineering
Borenstein, J. T., Terai, H., King, K. R., Weinberg, E. J., Kaazempur-Mofrad, M. R., & Vacanti, J. P. (2002) · Biomedical Microdevices · doi:10.1023/a:1016040212127 · Cited by 361
Self-citationEngineering cellular microenvironments to improve cell-based drug testing
Bhadriraju, K., & Chen, C. S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02273-0 · Cited by 355
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Advances in bioartificial liver devices
Allen, J. W., Hassanein, T., & Bhatia, S. N. (2001) · Hepatology · doi:10.1053/jhep.2001.26753 · Cited by 326
Research works printed but not linked: 2
- M.F. Kiani, A.R. Pries, L.L. Hsu, I.H. Sarelius, G.R. Cokelet, Am. J. Physiol. 266(5 Pt 2), H1822–H1828 (1994)
- A.R. Pries, D. Neuhaus, P. Gaehtgens, Am. J. Physiol. 263(6 Pt 2), H1770–H1778 (1992)
Cited by
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
“A similar approach has been used to integrate liver epithelium with microfabricated vascular networks [53], and fibroblasts were included as well in another liver model [54].”
MethodGodoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
“91 Direct-write laser technology has been utilized to form multiple-depth channel systems with diameter changes between parent and daughter vessels that mimic physiological systems.”
Microfabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
A liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Microfluidic fabrication of microengineered hydrogels and their application in tissue engineering
Chung, B. G., Lee, K.-H., Khademhosseini, A., & Lee, S.-H. (2012) · Lab Chip · doi:10.1039/c1lc20859d · Cited by 435
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“ALTEX 33(3), 2016 280 hepatocytes (Carraro et al., 2008; Goral et al., 2010; Ho et al., 2006; Leclerc et al., 2004; Lee et al., 2007b; Park et al., 2008; Powers et al., 2002; Toh et al., 2007, 2009), neurons (Rhee et al.”
Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
Nguyen, N.-T., Shaegh, S. A. M., Kashaninejad, N., & Phan, D.-T. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.008 · Cited by 210
“In vitro (pharmaco-kinetics) 1) Brain-on-a-chip [58, 59] 2) Heart-on-a-chip [60] 3) Liver-on-a-chip [13, 61-64] 4) Lung-on-a-chip [3, 65, 66] 5) Kidney-on-a-chip [67, 68] 6) Spleen-on-a-chip [51] 7) Intestine-on-a-chip [51, 69] 8) Gut-on-a-chip [70, 71] 9) Cornea-on-a-chip [60] 10) Blood vessel-on-a-chip [72-79] 11) M…”
Advanced Material Strategies for Tissue Engineering Scaffolds
Freed, L. E., Engelmayr, G. C., Borenstein, J. T., Moutos, F. T., & Guilak, F. (2009) · Advanced Materials · doi:10.1002/adma.200900303 · Cited by 210
Self-citationLatest Developments in Microfluidic Cell Biology and Analysis Systems
Salieb-Beugelaar, G. B., Simone, G., Arora, A., Philippi, A., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac1009707 · Cited by 207
Use of precision cut lung slices as a translational model for the study of lung biology
Liu, G., Betts, C., Cunoosamy, D. M., Åberg, P. M., Hornberg, J. J., Sivars, K. B., & Cohen, T. S. (2019) · Respiratory Research · doi:10.1186/s12931-019-1131-x · Cited by 206
Long-term ex vivo maintenance of testis tissues producing fertile sperm in a microfluidic device
Komeya, M., Kimura, H., Nakamura, H., Yokonishi, T., Sato, T., Kojima, K., Hayashi, K., Katagiri, K., Yamanaka, H., Sanjo, H., et al. (2016) · Scientific Reports · doi:10.1038/srep21472 · Cited by 202
Microfluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 202
Organs-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Marx, U., Walles, H., Hoffmann, S., Lindner, G., Horland, R., Sonntag, F., Klotzbach, U., Sakharov, D., Tonevitsky, A., & Lauster, R. (2012) · Alternatives to Laboratory Animals · doi:10.1177/026119291204000504 · Cited by 177
Riahi, R., Shaegh, S. A. M., Ghaderi, M., Zhang, Y. S., Shin, S. R., Aleman, J., Massa, S., Kim, D., Dokmeci, M. R., & Khademhosseini, A. (2016) · Scientific Reports · doi:10.1038/srep24598 · Cited by 172
Recurrent Urinary Tract Infection: A Mystery in Search of Better Model Systems
Murray, B. O., Flores, C., Williams, C., Flusberg, D. A., Marr, E. E., Kwiatkowska, K. M., Charest, J. L., Isenberg, B. C., & Rohn, J. L. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.691210 · Cited by 186
Tirumala, M. G., Anchi, P., Raja, S., Rachamalla, M., & Godugu, C. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.612659 · Cited by 169
Lee-Montiel, F. T., George, S. M., Gough, A. H., Sharma, A. D., Wu, J., DeBiasio, R., Vernetti, L. A., & Taylor, D. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217703978 · Cited by 141
Bioreactor technologies to support liver function in vitro
Ebrahimkhani, M. R., Neiman, J. A. S., Raredon, M. S. B., Hughes, D. J., & Griffith, L. G. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.011 · Cited by 135
“Application of microfluidic approaches to liver cell culture began to emerge about ten years ago in several labs, both as semi-empirical feasibility studies aimed at demonstration of long-term cell survival in PDMS devices [73][74][75][76] and as design-principle based visions of how to transform physiologically based…”
Cell Culture on MEMS Platforms: A Review
Ni, M., Tong, W. H., Choudhury, D., Rahim, N. A. A., Iliescu, C., & Yu, H. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10125411 · Cited by 162
“Since the media channel was directly under the cells, effective mass transport of metabolites and small proteins was achieved [231].”
BackgroundYu, F., Deng, R., Hao Tong, W., Huan, L., Chan Way, N., IslamBadhan, A., Iliescu, C., & Yu, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-13848-5 · Cited by 125
Cancer-on-a-chip systems at the frontier of nanomedicine
Zhang, Y. S., Zhang, Y.-N., & Zhang, W. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.03.011 · Cited by 127
Microfluidics-assisted in vitro drug screening and carrier production
Tsui, J. H., Lee, W.-H., Pun, S. H., Kim, J., & Kim, D. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.004 · Cited by 137
“In an interesting and novel approach, a microfluidic device was designed with architecture that models the hemodynamic properties of the native human microvascular bed and computational models were used to ensure physiologically-relevant flow and shear forces weremaintained in the chip [73].”
Review: Microfluidic applications in metabolomics and metabolic profiling
Kraly, J. R., Holcomb, R. E., Guan, Q., & Henry, C. S. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.037 · Cited by 126
Borenstein, J. T., Tupper, M. M., Mack, P. J., Weinberg, E. J., Khalil, A. S., Hsiao, J. C., & García‐Cardeña, G. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9361-1 · Cited by 122
“In addition, PDMS microfluidic constructs have been demonstrated for organ assist device applications in liver (Carraro et al. 2008; Leclerc et al. 2003), kidney (Kaazempur-Mofrad et al. 2004), and lung (Burgess et al. 2008).”
BackgroundSelf-citationMicrofluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Nanotechnology for tissue engineering: Need, techniques and applications
Kingsley, D. J., Ranjan, S., Dasgupta, N., & Saha, P. (2013) · Journal of Pharmacy Research · doi:10.1016/j.jopr.2013.02.021 · Cited by 134
Microfluidic Tissue Engineering and Bio‐Actuation
Filippi, M., Buchner, T., Yaşa, Ö., Weirich, S., & Katzschmann, R. K. (2022) · Advanced Materials · doi:10.1002/adma.202108427 · Cited by 133
Regeneration-on-a-chip? The perspectives on use of microfluidics in regenerative medicine
Harink, B., Le Gac, S., Truckenmüller, R., van Blitterswijk, C., & Habibovic, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50293g · Cited by 105
Organ-on-a-chip engineering: Toward bridging the gap between lab and industry
Ramadan, Q., & Zourob, M. M. (2020) · Biomicrofluidics · doi:10.1063/5.0011583 · Cited by 113
A Bioartificial Renal Tubule Device Embedding Human Renal Stem/Progenitor Cells
Sciancalepore, A. G., Sallustio, F., Girardo, S., Passione, L. G., Camposeo, A., Mele, E., Lorenzo, M. D., Costantino, V., Schena, F. P., & Pisignano, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087496 · Cited by 104
“compartments of blood vessels [14,15], liver [16,17], brain [18],”
Engineering extracellular matrix through nanotechnology
Kelleher, C. M., & Vacanti, J. P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0345.focus · Cited by 111
Self-citationTostões, R. M., Leite, S. B., Miranda, J. P., Sousa, M., Wang, D. I. C., Carrondo, M. J. T., & Alves, P. M. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.22920 · Cited by 86
Microfluidic Gut-on-a-Chip: Fundamentals and Challenges
Thomas, D. P., Zhang, J., Nguyen, N., & Ta, H. T. (2023) · Biosensors · doi:10.3390/bios13010136 · Cited by 95
“With the help of OoC, researchers have been able to study tissue–tissue interfaces and intricate organ-specific chemical and mechanical microenvironments, creating in vivo-like complex tissues such as the liver [1,2], brain [3], heart [4–6], kidney [7,8] and intestine [9–11].”
MethodHoganson, D. M., Pryor, H. I., Bassett, E. K., Spool, I. D., & Vacanti, J. P. (2011) · Lab on a Chip · doi:10.1039/c0lc00158a · Cited by 91
Self-citationYing, L., Zhu, Z., Xu, Z., He, T., Li, E., Guo, Z., Liu, F., Jiang, C., & Wang, Q. (2015) · PLOS ONE · doi:10.1371/journal.pone.0129593 · Cited by 81
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
Schneider, S., Gruner, D., Richter, A., & Loskill, P. (2021) · Lab on a Chip · doi:10.1039/d1lc00188d · Cited by 73
Application of whole-organ tissue engineering in hepatology
Uygun, B. E., Yarmush, M. L., & Uygun, K. (2012) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2012.140 · Cited by 76
Long-term flow through human intestinal organoids with the gut organoid flow chip (GOFlowChip)
Sidar, B., Jenkins, B. R., Huang, S., Spence, J. R., Walk, S. T., & Wilking, J. N. (2019) · Lab on a Chip · doi:10.1039/c9lc00653b · Cited by 73
Pozzobon, M., Ghionzoli, M., & Coppi, P. D. (2009) · Pediatric Surgery International · doi:10.1007/s00383-009-2478-8 · Cited by 80
“such as liver, have been done by developing structures with vascular channels to ensure an adequate network of vascular supply [3], major developments in regenerative M.”
BackgroundMicro/nano-fabrication technologies for cell biology
Qian, T., & Wang, Y. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0632-z · Cited by 73
“Micro/nano-technologies have also been applied in the clinic studies [43, 47], medical assays [2, 8], tissue engineering [1, 18, 24, 26], and drug development [29].”
Experimental approaches to vascularisation within tissue engineering constructs
Sarker, M., Chen, X. B., & Schreyer, D. J. (2015) · Journal of Biomaterials Science, Polymer Edition · doi:10.1080/09205063.2015.1059018 · Cited by 61
“[112] Therefore, several mathematical modeling and computational studies have been accomplished to optimize the architecture of vasculature considering the diffusional mass transfer, microfluidic behavior, and physiological data of human microvasculature.[113] Controlled positioning of vascular cell into scaffold can…”
BackgroundRecent advances and future applications of microfluidic live-cell microarrays
Rothbauer, M., Wartmann, D., Charwat, V., & Ertl, P. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.06.006 · Cited by 70
Principles of Biomimetic Vascular Network Design Applied to a Tissue-Engineered Liver Scaffold
Hoganson, D. M., Pryor, H. I., Spool, I. D., Burns, O. H., Gilmore, J. R., & Vacanti, J. P. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0118 · Cited by 67
“This architectural concept of a tissue scaffold results in liver cells adjacent to the channels of a vascular network separated by a semipermeable membrane.(8) The scaffold can be scaled up by stacking layers of the vascular networks and the adjacent liver cells.”
InfluentialSelf-citationA biodegradable microvessel scaffold as a framework to enable vascular support of engineered tissues
Ye, X., Lu, L., Kolewe, M. E., Park, H., Larson, B. L., Kim, E. S., & Freed, L. E. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.09.039 · Cited by 64
Microfluidic-Based Multi-Organ Platforms for Drug Discovery
Rezaei Kolahchi, A., Khadem Mohtaram, N., Pezeshgi Modarres, H., Mohammadi, M., Geraili, A., Jafari, P., Akbari, M., & Sanati-Nezhad, A. (2016) · Micromachines · doi:10.3390/mi7090162 · Cited by 53
“The microchannel geometry highly impacts the nutrient and oxygen delivery to tissues, and thus influences cell survival, proliferation, and differentiation [75].”
BackgroundMicrofluidic chip-based technologies: emerging platforms for cancer diagnosis
Li, Y., & Wang, Q. (2013) · BMC Biotechnology · doi:10.1186/1472-6750-13-76 · Cited by 63
“DNA, RNA, proteins, and cells) at the microscale [4].”
BackgroundEngineering of vascularized adipose constructs
Wiggenhauser, P. S., Müller, D. F., Melchels, F. P. W., Egaña, J. T., Storck, K., Mayer, H., Leuthner, P., Skodacek, D., Hopfner, Ú., Machens, H. G., et al. (2011) · Cell and Tissue Research · doi:10.1007/s00441-011-1226-2 · Cited by 56
“multiple experimental approaches to rebuild the native vascularization of tissue: vessel loop methods, precursor cell induction, templates of acellular blood vessels and artificial vessels (Borges et al. 2003; Carraro et al. 2008; Lokmic et al. 2007; Macchiarini et al. 2004; Mertsching et al. 2005; Tanaka et al. 2003).”
Advances in microfluidics for drug discovery
Lombardi, D., & Dittrich, P. S. (2010) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2010.521149 · Cited by 57
“Up to now, based on microfluidic technology, several models have been fabricated: blood vessels [146,147], muscles [148], bones [149], airways [150], liver [151-154], brain [155], gut [156] and kidney [157,158].”
BackgroundReality Check for Nanomaterial‐Mediated Therapy with 3D Biomimetic Culture Systems
Tay, C. Y., Muthu, M. S., Chia, S. L., Nguyen, K. T., Feng, S., & Leong, D. T. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201600476 · Cited by 59
Maguire, T., Novik, E., Chao, P., Barminko, J., Nahmias, Y., Yarmush, M., & Cheng, K.-C. (2009) · Current Drug Metabolism · doi:10.2174/138920009790820093 · Cited by 48
“, [38-52].”
Branched vascular network architecture: A new approach to lung assist device technology
Hoganson, D. M., Anderson, J. L., Weinberg, E. J., Swart, E. F., Orrick, B. K., Borenstein, J. T., & Vacanti, J. P. (2010) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2010.02.062 · Cited by 49
Self-citationRecent Advances in Microfluidic-Based Microphysiological Systems
Kang, S. (2021) · BioChip Journal · doi:10.1007/s13206-021-00043-y · Cited by 47
Sharma, R., Greenhough, S., Medine, C. N., & Hay, D. C. (2010) · BioMed Research International · doi:10.1155/2010/236147 · Cited by 53
“[133] demonstrated a microfluidics-based bilayer device with discrete parenchymal chambers designed using computational modelling.”
Methodvan Wenum, M., Chamuleau, R. A. F. M., van Gulik, T. M., Siliakus, A. R., Seppen, J., & Hoekstra, R. (2014) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2014.950651 · Cited by 48
“Still there is a group pioneering larger scale microfluidic devices, showing proof of principle that the microfluidic approach could work for a clinical BAL [37].”
BackgroundMicro and Nano-Scale Technologies for Cell Mechanics
Ünal, M., Alapan, Y., Jia, H. W., Varga, A. G., Angelino, K., Aslan, M., Sayın, I., Han, C., Jiang, Y., Zhang, Z., et al. (2014) · Nanobiomedicine · doi:10.5772/59379 · Cited by 55
“There have been encouraging breakthroughs in devising and constructing devices that resemble the structure of the human lungs [172-174], liver [175-178], intestines [164,179,180], kidneys [181,182], cancer tissue [183] and artificial cells in regenerative medicine [117,166,170].”
BackgroundA Role for 3D Printing in Kidney-on-a-Chip Platforms
Sochol, R. D., Gupta, N. R., & Bonventre, J. V. (2016) · Current Transplantation Reports · doi:10.1007/s40472-016-0085-x · Cited by 46
Proliferative human cell sources applied as biocomponent in bioartificial livers: a review
Nibourg, G. A. A., Chamuleau, R. A. F. M., van Gulik, T. M., & Hoekstra, R. (2012) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2012.685714 · Cited by 48
“, C3A-BALs demonstrated CYP1A2, CYP2B6, and CYP2E1 activity, but this study lacks comparison with PH-BALs [32].”
BackgroundResultInfluentialBiofabrication strategies for creating microvascular complexity
Clyne, A. M., Swaminathan, S., & Lantada, A. D. (2019) · Biofabrication · doi:10.1088/1758-5090/ab0621 · Cited by 46
Vascular Guidance: Microstructural Scaffold Patterning for Inductive Neovascularization
Müller, D., Chim, H., Bader, A., Whiteman, M., & Schantz, J. (2010) · Stem Cells International · doi:10.4061/2011/547247 · Cited by 42
“Organ patterning, such as fabrication of a parenchymal chamber modeled upon hepatic organ architecture for use as a liver-assist device, has also been reported [20].”
BackgroundIn vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
In vitro functional models for human liver diseases and drug screening: beyond animal testing
Paradiso, A., Volpi, M., Rinoldi, C., Celikkin, N., Contessi Negrini, N., Bilgen, M., Dallera, G., Pierini, F., Costantini, M., Święszkowski, W., et al. (2023) · Biomaterials Science · doi:10.1039/d1bm01872h · Cited by 40
Living cell‐laden hydrogels: Unleashing the future of responsive biohybrid systems
Hu, X., Lei, B., Li, S., Chen, L., & Li, Q. (2023) · Responsive materials · doi:10.1002/rpm.20230009 · Cited by 42
Refining Host-Pathogen Interactions: Organ-on-Chip Side of the Coin
Baddal, B., & Marrazzo, P. (2021) · Pathogens · doi:10.3390/pathogens10020203 · Cited by 42
“Since then, a plethora of studies have focused on the development of microfluidic devices that mimic diverse biological functions of airways [4,5], gut [6,7], liver [8,9], kidney [10], brain/blood-brain barrier [11,12], heart [13], skin [14], blood vessels [15], bones [16], adipose tissues [17], placenta [18], and dis…”
BackgroundLiver cell therapy and tissue engineering for transplantation
Vacanti, J. P., & Kulig, K. M. (2014) · Seminars in Pediatric Surgery · doi:10.1053/j.sempedsurg.2014.05.001 · Cited by 44
Self-citationA Novel Modular Bioreactor to In Vitro Study the Hepatic Sinusoid
Illa, X., Vila, S., Yeste, J., Peralta, C., Gracia-Sancho, J., & Villa, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111864 · Cited by 36
“This has traditionally been accomplished by the creation of scaffolds, by embedding cells in 3D hydrogels [19,20], by means of nanoporous membranes [21], or by culturing them on grooved substrates [22].”
MethodLiver-Assist Device With a Microfluidics-Based Vascular Bed in an Animal Model
Hsu, W., Carraro, A., Kulig, K. M., Miller, M. L., Mofrad, M. R. K., Weinberg, E. J., Entabi, F., Albadawi, H., Watkins, M. T., Borenstein, J. T., et al. (2010) · Annals of Surgery · doi:10.1097/sla.0b013e3181e982ba · Cited by 35
“Our group used MEMS design principles and microfabrication techniques to create a novel bilayer liver-assist device.(7) Prior analysis of BAL function in several clinical studies noted significant and rapidly occurring necrosis in the cellular component.”
BackgroundMethodSelf-citationEntry and passage behavior of biological cells in a constricted compliant microchannel
Raj, A., & Sen, A. K. (2018) · RSC Advances · doi:10.1039/c8ra02763c · Cited by 34
Ugodnikov, A., Persson, H., & Simmons, C. A. (2024) · Lab on a Chip · doi:10.1039/d3lc01027a · Cited by 33
Scalable Units for Building Cardiac Tissue
Ye, X., Lu, L., Kolewe, M. E., Hearon, K., Fischer, K. M., Coppeta, J. R., & Freed, L. E. (2014) · Advanced Materials · doi:10.1002/adma.201403074 · Cited by 33
Leaf-templated, microwell-integrated microfluidic chips for high-throughput cell experiments
Mao, M., He, J., Lu, Y., Li, X., Li, T., Zhou, W., & Li, D. (2018) · Biofabrication · doi:10.1088/1758-5090/aaa900 · Cited by 32
Current and Future Perspectives of the Use of Organoids in Radiobiology
Nagle, P. W., & Coppes, R. P. (2020) · Cells · doi:10.3390/cells9122649 · Cited by 35
“Organ-on-a-chip devices have been established for various other tissues, including lung [138], kidney [139] and liver [140].”
BackgroundChiara, F. D., Ferret-Miñana, A., & Ramón‐Azcón, J. (2021) · Biomedicines · doi:10.3390/biomedicines9030248 · Cited by 33
“Fluid shear stresses can be controlled independently of physical and chemical gradients by altering flow rates or channel dimensions [68,69] and separating cells from the flow path using a nano porous membrane [68] or micro-engineered posts that restrict cell passage [70].”
BackgroundMethodA microfluidic device mimicking acinar concentration gradients across the liver acinus
Shih, M.-C., Tseng, S., Weng, Y., Chu, I., & Liu, C. (2013) · Biomedical Microdevices · doi:10.1007/s10544-013-9762-z · Cited by 33
“Cultured liver cells could be damaged by the culture medium flow and the induced shear stress (Carraro et al. 2008; Leclerc et al. 2008; Park et al. 2005).”
BackgroundMultiscale tissue engineering for liver reconstruction
Sudo, R. (2014) · Organogenesis · doi:10.4161/org.27968 · Cited by 32
“Carraro et al.(38) developed a microfluidics-based bilayer device with a discrete parenchymal chamber modeled on the liver architecture.”
BackgroundImaging live cells at high spatiotemporal resolution for lab-on-a-chip applications
Chin, L. K., Lee, C., & Chen, B. (2016) · Lab on a Chip · doi:10.1039/c5lc01556a · Cited by 31
Multi-organ on a chip for personalized precision medicine
Palaninathan, V., Kumar, V., Maekawa, T., Liepmann, D., Paulmurugan, R., Eswara, J. R., Ajayan, P. M., Augustine, S., Malhotra, B. D., Viswanathan, S., et al. (2018) · MRS Communications · doi:10.1557/mrc.2018.148 · Cited by 29
A microfluidic chip for permeability assays of endothelial monolayer
Shao, J., Wu, L., Wu, J., Zheng, Y., Zhao, H., Lou, X., Jin, Q., & Zhao, J. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9362-0 · Cited by 31
Transport and shear in a microfluidic membrane bilayer device for cell culture
Inamdar, N. K., Griffith, L. G., & Borenstein, J. T. (2011) · Biomicrofluidics · doi:10.1063/1.3576925 · Cited by 31
Self-citationIntegrating polyurethane culture substrates into poly(dimethylsiloxane) microdevices
Moraes, C., Kagoma, Y. K., Beca, B. M., Tonelli-Zasarsky, R. L. M., Sun, Y., & Simmons, C. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.066 · Cited by 31
“However, many multilayer soft lithography systems are limited to culturing cells directly on a PDMS substrate [1–4,11–17].”
BackgroundPulmonary Tissue Engineering using Dual-Compartment Polymer Scaffolds with Integrated Vascular Tree
Fritsche, C., Simsch, O., Weinberg, E. J., Orrick, B. K., Stamm, C., Mofrad, M. R. K., Borenstein, J. T., Hetzer, R., & Vacanti, J. P. (2009) · The International Journal of Artificial Organs · doi:10.1177/039139880903201001 · Cited by 31
Self-citationRegenerative medicine for congenital malformations
Coppi, P. D. (2013) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2012.11.005 · Cited by 28
“Although scaffolds could ultimately represent the exclusive tool of tissue engineering and several attempts have been made generating whole organs, such as liver, by developing structures with vascular channels to ensure an adequate network of blood supply [57].”
BackgroundModular microfluidic system as a model of cystic fibrosis airways
Skolimowski, M., Nielsen, M. W., Abeille, F., Skafte-Pedersen, P., Sabourin, D., Fercher, A., Papkovsky, D. B., Molin, S., Taboryski, R., Sternberg, C., et al. (2012) · Biomicrofluidics · doi:10.1063/1.4742911 · Cited by 27
Membrane-integrated microfluidic device for high-resolution live cell imaging
Epshteyn, A. A., Maher, S. P., Taylor, A. J., Holton, A., Borenstein, J. T., & Cuiffi, J. D. (2011) · Biomicrofluidics · doi:10.1063/1.3647824 · Cited by 28
Self-citationImaging therapeutic peptide transport across intestinal barriers
Larsen, J. B., Taebnia, N., Dolatshahi‐Pirouz, A., Eriksen, A. Z., Hjørringgaard, C. U., Kristensen, K., Larsen, N. W., Larsen, N. B., Marie, R., Mündler, A.-K., et al. (2021) · RSC Chemical Biology · doi:10.1039/d1cb00024a · Cited by 28
Drug-mediated toxicity: illuminating the ‘bad’ in the test tube by means of cellular assays?
Tralau, T., & Luch, A. (2012) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2012.03.015 · Cited by 24
Advancing hepatotoxicity assessment: current advances and future directions
Kim, Y., Kim, Y., & Kim, Y. (2025) · Toxicological Research · doi:10.1007/s43188-025-00289-w · Cited by 23
“They achieved this by generating physical and chemical gradients through fluid flow within the chip [151–155].”
Microfabricated Physiological Models for In Vitro Drug Screening Applications
Ugolini, G. S., Cruz‐Moreira, D., Visone, R., Redaelli, A. C. L., & Rasponi, M. (2016) · Micromachines · doi:10.3390/mi7120233 · Cited by 25
Innovation for hepatotoxicity in vitro research models: A review
Han, W., Wu, Q., Zhang, X., & Duan, Z. (2018) · Journal of Applied Toxicology · doi:10.1002/jat.3711 · Cited by 23
“The device maintained long‐term (14 days) liver cell viability, proliferation and hepatic function (Carraro et al., 2008) (Figure 2A).”
BackgroundZhang, Y., Li, W., Pan, P., Tang, J., Dong, B., Xing, F., & Zhu, G. (2022) · Composites Part B Engineering · doi:10.1016/j.compositesb.2022.110056 · Cited by 21
He, J., Chen, W., Deng, S., Xie, L., Feng, J., Geng, J., Jiang, D., Dai, H., & Wang, C. (2017) · RSC Advances · doi:10.1039/c7ra06752f · Cited by 20
Metadata
- Authors
- Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., & Neville, C.
- Affiliations
- University of Padua (IT)
- Massachusetts General Hospital (US)
- Harvard University (US)
- Draper Laboratory (US)
- Corresponding author
- Neville, Craig
- Venue
- Biomedical Microdevices
- Published
- 2008-07-05
- Volume
- 10
- Issue
- 6
- Pages
- 795-805
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2031785809
- Cited by
- 168
- References
- 23
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 9 · 2022: 11 · 2021: 8 · 2020: 4 · 2019: 7 · 2018: 7 · 2017: 5 · 2016: 14 · 2015: 8 · 2014: 13 · 2013: 19 · 2012: 11
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Biomedical Microdevices (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- bilayer devices, soft lithography, nanoporous membranes, hepatocyte culture, hepatoma cells, primary rat hepatocytes, serum protein synthesis, drug discovery, toxicity testing, artificial liver support
- MeSH terms
- Animals, Drug Evaluation, Preclinical, Humans, Male, Membranes, Artificial, Rats, Inbred Lew, Silicon, Porosity, Cell Culture Techniques, Liver, Artificial, Hepatocytes, Cell Line, Tumor, Microfluidic Analytical Techniques, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.