A physiologically realistic in vitro model of microvascular networks
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Existing microfluidic devices, e.g. parallel plate flow chambers, do not accurately depict the geometry of microvascular networks in vivo. We have developed a synthetic microvascular network (SMN) on a polydimethalsiloxane (PDMS) chip that can serve as an in vitro model of the bifurcations, tortuosities, and cross-sectional changes found in microvascular networks in vivo. Microvascular networks from a cremaster muscle were mapped using a modified Geographical Information System, and then used to manufacture the SMNs on a PDMS chip. The networks were cultured with bovine aortic endothelial cells (BAEC), which reached confluency 3–4 days after seeding. Propidium iodide staining indicated viable and healthy cells showing normal behavior in these networks. Anti-ICAM-1 conjugated 2-μm microspheres adhered to BAEC cells activated with TNF-α in significantly larger numbers compared to control IgG conjugated microspheres. This preferential adhesion suggests that cultured cells retain an intact cytokine response in the SMN. This microfluidic system can provide novel insight into characterization of drug delivery particles and dynamic flow conditions in microvascular networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Synthetic Microvascular Networks for Quantitative Analysis of Particle Adhesion
Prabhakarpandian, B., Pant, K., Scott, R. C., Patillo, C. B., Irimia, D., Kiani, M. F., & Sundaram, S. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9170-y · Cited by 68
Self-citation
Cited by
Using shape effects to target antibody-coated nanoparticles to lung and brain endothelium
Kolhar, P., Anselmo, A. C., Gupta, V., Pant, K., Prabhakarpandian, B., Ruoslahti, E., & Mitragotri, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308345110 · Cited by 646
Self-citationFactors Controlling Nanoparticle Pharmacokinetics: An Integrated Analysis and Perspective
Moghimi, S. M., Hunter, A. C., & Andresen, T. L. (2012) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010611-134623 · Cited by 545
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Doshi, N., Prabhakarpandian, B., Rea-Ramsey, A., Pant, K., Sundaram, S., & Mitragotri, S. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.04.007 · Cited by 301
Self-citationTsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Microfluidics‐based 3D cell culture models: Utility in novel drug discovery and delivery research
Gupta, N., Liu, J. R., Patel, B., Solomon, D. E., Vaidya, B., & Gupta, V. (2016) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10013 · Cited by 236
Oxygen and nutrient delivery in tissue engineering: Approaches to graft vascularization
Rademakers, T., Horvath, J. M., Blitterswijk, C. A., & LaPointe, V. L. S. (2019) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2932 · Cited by 215
“Polydimethylsiloxane (PDMS) has been frequently used for replica moulding (Duffy, McDonald, Schueller, et al., 1998; Leclerc, Sakai, & Fujii, 2003; Rosano et al., 2009; Shin et al., 2004) due to its low chemical reactivity and non‐toxicity towards endothelial cells for a duration of up to 4 weeks…”
MethodVascular Targeting of Nanocarriers: Perplexing Aspects of the Seemingly Straightforward Paradigm
Howard, M., Zern, B. J., Anselmo, A. C., Shuvaev, V. V., Mitragotri, S., & Muzykantov, V. (2014) · ACS Nano · doi:10.1021/nn500136z · Cited by 192
Mechanisms of radiation-induced endothelium damage: Emerging models and technologies
Wijerathne, H., Langston, J. C., Yang, Q., Sun, S., Miyamoto, C., Kilpatrick, L. E., & Kiani, M. F. (2021) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2021.02.007 · Cited by 173
Self-citationCardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
“Rosano et al.108 mapped a mouse cremaster muscle and used it to build a PDMS mold of the vascular network.”
MethodKhodabandehlou, K., Masehi-Lano, J. J., Poon, C., Wang, J., & Chung, E. J. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217693116 · Cited by 91
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
Synthetic tumor networks for screening drug delivery systems
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Garson, C. J., Mills, I. R., Matar, M. M., Fewell, J. G., & Pant, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.01.018 · Cited by 57
Self-citationBiomimetic channel modeling local vascular dynamics of pro-inflammatory endothelial changes
Thomas, A., Daniel Ou-Yang, H., Lowe-Krentz, L., Muzykantov, V. R., & Liu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4936672 · Cited by 46
Metadata
- Authors
- Rosano, J. M., Tousi, N., Scott, R. C., Krynska, B., Rizzo, V., Prabhakarpandian, B., Pant, K., Sundaram, S., & Kiani, M. F.
- Venue
- Biomedical Microdevices
- Published
- 2009-05-19
- Volume
- 11
- Issue
- 5
- Pages
- 1051-1057
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W2085849664
- Cited by
- 83
- References
- 2
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.