Endothelial cell behaviour within a microfluidic mimic of the flow channels of a modular tissue engineered construct
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To study the effect of disturbed flow patterns on endothelial cells, the channels found within a modular tissue engineering construct were reproduced in a microfluidic chip and lined with endothelial cells whose resulting phenotype under flow was assessed using confocal microscopy. Modular tissue engineered constructs formed by the random packing of sub-millimetre, cylindrically shaped, endothelial cell-covered modules into a larger container creates interconnected channels that permit the flow of fluids such as blood. Due to the random packing, the flow path is tortuous and has the potential to create disturbed flow, resulting in an activated endothelium. At an average shear stress of 2.8 dyn cm−2, endothelial cells within channels of varying geometries showed higher amounts of activation, as evidenced by an increase in ICAM-1 and VCAM-1 levels with respect to static controls. VE-cadherin expression also increased, however, it appeared discontinuous around the perimeter of the cells. An increase in flow (15.6 dyn cm−2) was sufficient to reduce ICAM-1 and VCAM-1 expression to a level below that of static controls for many disturbed flow-prone channels that contained branches, curves, expansions and contractions. VE-cadherin expression was also reduced and became discontinuous in all channels, possibly due to paracrine signaling. Other than showing a mild correlation to VE-cadherin, which may be linked through a cAMP-initiated pathway, KLF2 was found to be largely independent of shear stress for this system. To gauge the adhesiveness of the endothelium to leukocytes, THP-1 cells were introduced into flow-conditioned channels and their attachment measured. Relative to static controls, THP-1 adhesion was reduced in straight and bifurcating channels. However, even in the presence of flow, areas where multiple channels converged were found to be the most prone to THP-1 attachment. The microfluidic system enabled a full analysis of the effect of the tortuous flow expected in a modular construct on endothelial cell phenotype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Synthetic Microvascular Networks for Quantitative Analysis of Particle Adhesion
Prabhakarpandian, B., Pant, K., Scott, R. C., Patillo, C. B., Irimia, D., Kiani, M. F., & Sundaram, S. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9170-y · Cited by 68
Cited by
Probing nanoparticle translocation across the permeable endothelium in experimental atherosclerosis
Kim, Y., Lobatto, M. E., Kawahara, T., Lee Chung, B., Mieszawska, A. J., Sanchez-Gaytan, B. L., Fay, F., Senders, M. L., Calcagno, C., Becraft, J., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1322725111 · Cited by 189
“1, 1, and 10 dyne/cm(2), respectively (32).”
Bone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
Khodabandehlou, K., Masehi-Lano, J. J., Poon, C., Wang, J., & Chung, E. J. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217693116 · Cited by 91
Biomimetic channel modeling local vascular dynamics of pro-inflammatory endothelial changes
Thomas, A., Daniel Ou-Yang, H., Lowe-Krentz, L., Muzykantov, V. R., & Liu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4936672 · Cited by 46
Metadata
- Authors
- Khan, O. F., & Sefton, M. V.
- Venue
- Biomedical Microdevices
- Published
- 2010-09-15
- Volume
- 13
- Issue
- 1
- Pages
- 69-87
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W1984701838
- Cited by
- 59
- References
- 2
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endothelial cell behaviour within a microfluidic mimic of the flow channels of a modular tissue engineered construct. https://app.cochat.ai/papers/10.1007/s10544-010-9472-8
- The paper
- Khan, O. F., & Sefton, M. V. (2011). Endothelial cell behaviour within a microfluidic mimic of the flow channels of a modular tissue engineered construct. Biomedical Microdevices. https://doi.org/10.1007/s10544-010-9472-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.