Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The vascular endothelium and shear stress are critical determinants of physiological hemostasis and platelet function in vivo, yet current diagnostic and monitoring devices do not fully incorporate endothelial function under flow in their assessment and, therefore, they can be unreliable and inaccurate. It is challenging to include the endothelium in assays for clinical laboratories or point-of-care settings because living cell cultures are not sufficiently robust. Here, we describe a microfluidic device that is lined by a human endothelium that is chemically fixed, but still retains its ability to modulate hemostasis under continuous flow in vitro even after few days of storage. This device lined with a fixed endothelium supports formation of platelet-rich thrombi in the presence of physiological shear, similar to a living arterial vessel. We demonstrate the potential clinical value of this device by showing that thrombus formation and platelet function can be measured within minutes using a small volume (0.5 mL) of whole blood taken from subjects receiving antiplatelet medications. The inclusion of a fixed endothelial microvessel will lead to biomimetic analytical devices that can potentially be used for diagnostics and point-of-care applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, microfluidic devices (i.e. thrombosis-on-chip devices) are of interest to mimic a range of flows and shear stresses, starting from low (i.e. in veins) to high values (i.e. in arteries) [287–290].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [287]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices possess endothelialized lumen that can reliably capture several features of blood vessels such as atherosclerosis (i.e. fatty plaque deposition and formation) and bifurcations (i.e. branches and bends) by changing the channel geometries and flow patterns, ranging from laminar steady flow to pulsatile flow [287–290,295–304].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [287]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Proof-of-concept studies were performed in which the VoC was treated with the inflammatory cytokine tumor necrosis factor (TNF)-α, and patterns of platelet adhesion upon human whole blood perfusion were analysed (Jain et al., 2016).”
From Considering future qualification for regulatory science in the early development of microphysiological systems: a case study of microthrombosis in a Vessel-on-Chip (2024) · cites this paper as Jain et al., 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 4×
“…device design and fabrication The microfluidic device was designed using AutoCAD software, master templates were fabricated by photolithography on Si (100) wafers (University Wafer Corp.) and soft lithography was used to prepare the devices with polydimethylsiloxane (PDMS) (Duffy et al. 1998).”
MethodInfluentialReconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“…2000) In previous studies, we showed that treatment of living endothelium cultured in microfluidic channels with the inflammatory cytokine TNF-α results in an increase in expression of surface adhesion molecules (e.g., ICAM-1, VCAM-1) within 4 h after addition (Benam et al. 2016; Huh et al. 2010).”
MethodSelf-citationIn vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894 · cited 1×
“Over the last decade, microfluidic devices that contain hollow channels lined by living endothelium have been exposed to flowing blood to study the basic science of thrombosis in vitro (Colace et al. 2013; Neeves et al. 2013; Tsai et al. 2012; Zheng et al. 2012).”
BackgroundSmall airway-on-a-chip enables analysis of human lung inflammation and drug responses in vitro
Benam, K. H., Villenave, R., Lucchesi, C., Varone, A., Hubeau, C., Lee, H.-H., Alves, S. E., Salmon, M., Ferrante, T. C., Weaver, J. C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3697 · Cited by 816 · cited 1×
“…2000) In previous studies, we showed that treatment of living endothelium cultured in microfluidic channels with the inflammatory cytokine TNF-α results in an increase in expression of surface adhesion molecules (e.g., ICAM-1, VCAM-1) within 4 h after addition (Benam et al. 2016; Huh et al. 2010).”
MethodSelf-citationFalati, S., Gross, P., Merrill-Skoloff, G., Furie, B. C., & Furie, B. (2002) · Nature Medicine · doi:10.1038/nm782 · Cited by 669 · cited 2×
“Also was similar to that of clots formed on living endothelium in vivo, (Cooley 2011; Falati et al. 2002) and significantly different from those formed on bare collagen-coated flow chambers (shape of long tethers) (Colace et al. 2011) Taken together, these results demonstrate that the microfluidic…”
BackgroundResult(2005) · PubMed · Cited by 567
Tumor necrosis factor and interleukin-1 serum levels during severe sepsis in humans
DAMAS, P., REUTER, A., GYSEN, P., DEMONTY, J., LAMY, M., & FRANCHIMONT, P. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00001 · Cited by 486 · cited 1×
“We first perfused a microdevice containing fixed endothelium that was pretreated with a physiologically relevant dose of TNF-α (5 ng/mL) (Damas et al. 1989; Kim et al. 2014; Schlitt et al. 2004) with whole blood from a healthy donor containing 0 to 100 μg/mL (clinical range ~1–10 μg/mL) (Mascelli…”
MethodBombeli, T., Schwartz, B. R., & Harlan, J. M. (1998) · The Journal of Experimental Medicine · doi:10.1084/jem.187.3.329 · Cited by 425 · cited 1×
“Notably, these findings also indicate that the fixed surface of the endothelium retains its ability to modulate platelet interactions via the GPIIb/IIIa pathway that is involved in multiple thrombotic and vascular processes, as this is the target of abciximab (Bombeli et al. 1998).”
BackgroundROLE OF ENDOTHELIUM IN THROMBOSIS AND HEMOSTASIS
Wu, M. D., & Thiagarajan, M. D. (1996) · Annual Review of Medicine · doi:10.1146/annurev.med.47.1.315 · Cited by 384 · cited 2×
“(Alexandru et al. 2012; Lowenberg et al. 2010; Siddiqui et al. 2013; Wu and Thiagarajan 1996) Yet no practical diagnostic assays exist that can measure cross-talk between platelets and inflamed vessel walls in the presence of physiological shear.”
BackgroundCD14+CD16+ monocytes in coronary artery disease and their relationship to serum TNF-α levels
Blankenberg, S., Espinola-Klein, C., Dopheide, J., Bickel, C., Lackner, K., Iz, M., Meyer, J., Darius, H., Rupprecht, H., Schlitt, A., et al. (2004) · Thrombosis and Haemostasis · doi:10.1160/th04-02-0095 · Cited by 301 · cited 1×
“…containing fixed endothelium that was pretreated with a physiologically relevant dose of TNF-α (5 ng/mL) (Damas et al. 1989; Kim et al. 2014; Schlitt et al. 2004) with whole blood from a healthy donor containing 0 to 100 μg/mL (clinical range ~1–10 μg/mL) (Mascelli et al. 1998) of the…”
Research works printed but not linked: 3
- Lowenberg EC Meijers JC Levi M Neth. J. Med. 2010 68 242 20558854
- Papaioannou TG Stefanadis C Hell. J. Cardiol. HJC Hellēnikē Kardiologikē Epitheōrēsē 2005 46 9 15807389
- Rossi F Rossi E Pareti FI Colli S Tremoli E Gallo L Haematologica 2001 86 192 11224490
Cited by
Items 101–152 of 152
Technical aspects of megaureter repair.
Hendren, W. H. (1977) · PubMed · Cited by 9
Leslie, D. C., Waterhouse, A., & Ingber, D. E. (2017) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2017.03.149 · Cited by 7
Self-citationLei, Y., Tian, Y., Yang, J., Liu, B., Zou, H., Hauser, C. A. E., Huang, X., Li, Z. A., & Cui, D. (2026) · Research · doi:10.34133/research.1405 · Cited by 8
“This platform can be applied to analyze antiplatelet drug effects, demonstrating the clinical diagnostic feasibility of fixed endothelialized chips [ 164 ].”
Fukushi, M., Kinoshita, K., Yamada, M., Yajima, Y., Utoh, R., & Seki, M. (2019) · RSC Advances · doi:10.1039/c9ra00257j · Cited by 6
Li, Y., Lu, Y., Chen, Q., Kang, Y., & Yu, L. D. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0194-z · Cited by 6
Creating patient-specific vein models to characterize wall shear stress in hemodialysis population
Moya-Rodríguez, A., Xie, B., Cook, D., Klineberg, M., Nathan, S., Hammes, M. S., & Basu, A. (2022) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2022.10.010 · Cited by 5
“Finally, adding a layer of endothelial cells to the inner walls of these millifluidic devices 466 [27] and quantifying their biochemical responses under flow [28-30] are necessary to 467 biologically complement generated WSS profiles [13].”
MethodBacci, M., Cancellara, A., Ciceri, R., Romualdi, E., Pessi, V., Tumminello, F., Fantuzzi, M., Donadini, M. P., Lodigiani, C., Bella, S. D., et al. (2023) · Biomedicines · doi:10.3390/biomedicines11061669 · Cited by 5
Organs-on-Chips: a new paradigm for safety assessment of drug-induced thrombosis
Ng, P. R., Belgur, C., Barthakur, S., van der Meer, A. D., Hamilton, G. A., & Barrile, R. (2019) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2019.08.004 · Cited by 5
Self-citationGetting a good view:in vitroimaging of platelets under flow
Oshinowo, O. T., Lambert, T. P., Sakurai, Y., Copeland, R., Hansen, C. E., Lam, W. A., & Myers, D. R. (2020) · Platelets · doi:10.1080/09537104.2020.1732320 · Cited by 6
Investigational New Drug ‐enabling studies in a human vessel‐chip: Are we there yet?
Kumar, A., Maringanti, R., Mathur, T., Abe, J., Le, N., Xiao, Y., Wang, G., Mojiri, A., Cooke, J. P., & Jain, A. (2026) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70129 · Cited by 4
“81 Building on these advances, a dual-channel model was developed incorporating both vascular endothelial and lung epithelial layers separated by a thin membrane, enabling investigation of thrombosis triggered by epithelial-derived inflammatory stimuli such as lipopolysaccharide (LPS).”
Self-citationIn vitro and ex vivo Flow Models for Arterial Thrombosis: A Systematic Review
Eyisoylu, H., Cagnazzo, R., Koenderink, G. H., de Maat, M. P. M., & van Beusekom, H. M. M. (2025) · Cardiology · doi:10.1159/000548375 · Cited by 4
Chen, F., Wu, S., Fu, J., Lv, X., Chai, H., Gao, L., & Yu, L. D. (2022) · New Journal of Chemistry · doi:10.1039/d2nj02091b · Cited by 4
A three-dimensional vessel-on-chip model to study Puumala orthohantavirus pathogenesis
Noack, D., van Haperen, A., van den Hout, M. C. G. N., Marshall, E. M., Koutstaal, R. W., van Duinen, V., Bauer, L., van Zonneveld, A. J., van IJcken, W. F. J., Koopmans, M., et al. (2024) · Lab on a Chip · doi:10.1039/d4lc00543k · Cited by 4
Highly Stable Fluor-Free Slippery Liquid Infused Surfaces
Vaillard, A.-S., Saget, M., Braud, F., Lippert, M., Keirsbulck, L., Jimenez, M., Coffinier, Y., & Thomy, V. (2023) · Surfaces and Interfaces · doi:10.1016/j.surfin.2023.103296 · Cited by 4
Effect of Pneumatic Tubing System Transport on Platelet Apheresis Units
Zilberman‐Rudenko, J., Zhao, F. Z., Reitsma, S. E., Mitrugno, A., Pang, J., Shatzel, J. J., Rick, B., Tyrrell, C., Hasan, W., McCarty, O. J. T., et al. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-0361-2 · Cited by 4
Marin, T. M., & Pagani, E. (2018) · Vigilância Sanitária em Debate · doi:10.22239/2317-269x.01053 · Cited by 5
Design strategy primer for organ-on-chips.
Cao, T., Xu, P., Yang, C., Chen, Y., Wang, Y., Zhang, J., & Ye, F. (2025) · PubMed Central · doi:10.12336/bmt.24.00070 · Cited by 4
“For instance, the lung-on-a-chip designed by Zhang 39 employed alveolar epithelial cells, pulmonary vascular endothelial cells, and Matrigel to recreate the alveolar microenvironment and functions, simulating TCC represents the prevalent OoCs type, encompassing lung-on-a-chip, 40 liver-on-a-chip,…”
Preclinical Models of Venous Thrombosis: A Critical Appraisal for Translational Research
Bhopal, A. S., Luo, Y., Grover, L. M., & Brill, A. G. (2026) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.126.323862 · Cited by 2
New horizons of microphysiological systems: India forging its path in human-relevant research
Parvatam, S., Mahadik, K., Banerjee, A. A., Patil, K., Radha, V., & Rao, M. (2023) · Biology Open · doi:10.1242/bio.059847 · Cited by 2
“Two other talks were focussed on vessel-on-chip lined with human endothelium to model atherosclerosis (Jain et al., 2016) and a 3D-printed lung model to study pneumonia, asthma, tuberculosis, cystic fibrosis, and COVID-19 (Nandeesha et al.”
MethodTargeting Epigenetics in Pulmonary Arterial Hypertension
Rahman, K. M. T., Islam, T., Islam, M. F., Carbone, R. G., Butzin, N. C., & Ali, M. K. (2023) · Springer eBooks · doi:10.1007/978-981-99-4780-5_14 · Cited by 2
Netala, V. R., Hou, T., & Zhang, Z. (2025) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2025.107171 · Cited by 4
Biophysical perspectives of the spatiotemporal dynamics of plasma coagulation under flow
Megalinskii, A. D., Nechipurenko, Y. D., Panteleev, M. A., & Nechipurenko, D. Y. (2025) · Biophysical Reviews · doi:10.1007/s12551-025-01365-z · Cited by 2
“Microfluidic “organ-on-a-chip” systems lined with endothelium allow local injury under near-physiological shear (Sakurai et al. 2023; Brouns et al. 2020; Jain et al. 2016; Costa et al. 2017).”
Human induced pluripotent stem cell-derived endothelial cells in thrombosis-on-a-chip devices
Albers, H. J., Simão, J. P. D. S., Middelkamp, H. H. T., Mummery, C. L., Passier, R., van den Berg, A., Orlova, V. V., van der Meer, A. D., Tseng, F., & Lee, G.-B. (2018) · University of Twente Research Information · Cited by 2
Kapileshwarkar, Y., Gelmini, L., Tseng, Y.-S., Jackson, T., Gao, X., Richards, K., Dokas, M., Walters, H. L., & Hines, P. C. (2020) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2019.101191 · Cited by 2
Taute, F., Homs-Corbera, A., & Gaudriault, P. (2021) · Open Research Europe · doi:10.12688/openreseurope.13335.1 · Cited by 3
Mery, C. M. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.04.024 · Cited by 2
“Lung-on-a-chip” as an instrument for studying the pathophysiology of human respiration
Zhukova, O. A., Ozerskaya, I. V., Basmanov, D. V., Stolyarov, V. Y., Bogush, V. G., Kolesov, V. V., Zykov, K. A., Yusubalieva, G. M., & Baklaushev, V. P. (2024) · Journal of clinical practice · doi:10.17816/clinpract637140 · Cited by 1
“Воспалительная активация эндо-телия сосудов фактором некроза опухоли альфа (tumour necrosis factor alpha, TNF-α ) вызывала бы-строе рекрутирование тромбоцитов и приводила к образованию тромба, аналогично тому, как это происходит в воспалительно изменённых микросо-судах in vivo [106].”
Batista, A. M., Carlos, G. B., Alape, J. M. R., Machado, N., Bandeira, C. C. S., Nogueira, J. J., & Martinho, H. D. S. (2025) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2025.142871 · Cited by 1
Hemadyne: accordion-inspired perfusion for microphysiological systems
Kumar, A., Pattanshetti, S., Patel, R. D., Pandey, R., Mahalingam, E., Rahbar, E., & Jain, A. (2026) · Nature Communications · doi:10.1038/s41467-026-73722-9 · Cited by 1
“MPS, such as the vessel-chip, serves as a micro-fl uidic avatar of blood vessels 13 – 18 , where fl ow may be scaled to mimic the wall shear stress of vessels, including arteries and veins, arterioles and venules, and the microscopic capillaries.”
Self-citationEnabling Technologies in Vascular Biology: Microphysiological Systems, Organoids, and Beyond
Gholizadeh, H., & Benam, K. H. (2026) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.126.323054 · Cited by 1
Kasukurti, A., Lakshmanan, H. H. S., Tiwari, S., & Maddala, J. (2019) · Springer eBooks · doi:10.1007/978-3-662-59596-1_9 · Cited by 2
Translational Pharmacology and Clinical Trials
Li, M., & Stewart, A. G. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820472-6.00028-1 · Cited by 2
Organs-on-a-chip in precision medicine
Gupta, V., Sharma, R., Bansal, R., Kaur, G., Kumar, S., & Bansal, P. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00019-x · Cited by 2
Engineering Organoid Systems to Model Health and Disease
Ankrum, J. A., Bartosh, T. J., Yin, X., Brown, A. J., Burand, A. J., & Boland, L. K. (2017) · Molecular and translational medicine · doi:10.1007/978-3-319-57153-9_10
Biomarkers of platelet dysfunction in non-clinical safety studies and humans
Smith, J. D., Narayanan, P., & Li, N. (2019) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2019.11.001
Albers, H. J. (2020) · doi:10.3990/1.9789036549707
Microfluidic platform for multiple parameters readouts in a point-of-care
Karimi, S. (2020) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-190676 · Cited by 1
Coenen, D. M. (2021) · Research Publications (Maastricht University) · doi:10.26481/dis.20210625dc
"Microfluidic vessels-on-chips for vascular disease modelling"
Middelkamp, H. H. T. (2023) · doi:10.3990/1.9789036557245
Kukla, D. A., Sharapova, T., Ciurlionis, R., Vleet, T. V., Wetter, J. M., Peterkin, V. C., Lee, A. J., Marsh, K. C., Wang, Y., Mahalingaiah, P. K. S., et al. (2025) · Toxicological Sciences · doi:10.1093/toxsci/kfaf099
Platelet–Endothelial Interactions in Thrombosis and Health
Nagao, R. J., López, J. A., & Zheng, Y. Y. (2025) · Springer eBooks · doi:10.1007/978-3-031-96344-5_8
Giles, J., & Giles, J. (2023) · UA Campus Repository (The University of Arizona)
Vuong, A. (2026) · UNSWorks (University of New South Wales, Sydney, Australia) · doi:10.26190/unsworks/32003
Forces in a microvessel-on-chip : system development,poroelasticity mechanics and cellular response
Dessalles, C. A. (2021) · theses.fr (ABES) · doi:10.70675/5fc1fb53z8432z4709z891cz8bf087f8ff29 · Cited by 2
Neosinus and Valve Thrombosis After Transcatheter Aortic Valve Replacement
Chen, N., Mao, Y., & Zhang, H. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.048121
Prospects of microfluidic analytical systems for biomedical applications
Singh, I., Sharma, N. K., Dakal, T. C., & Maurya, P. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36328-3.00001-2
Gershon, S., Grutman, T., & Ilovitsh, T. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.06.18.733085
Vascular remodeling in thrombo-inflammation
Vanessa, B. (2026) · Research Publications (Maastricht University) · doi:10.26481/dis.20260907vb
Lab-on-a-chip approaches for blood flow and thrombosis research: A comprehensive review
Barua, D. R., Paul, D., Das, D., Poddar, A., & Datta, S. (2026) · Mechanobiology · doi:10.1177/29780241261479995
Probing the Mechano-Redox Control of Cell Movement Using Microfluidic Assays
Dupuy, A., Zhang, K., Chiu, J., Ju, L. A., & Passam, F. H. (2026) · Methods in molecular biology · doi:10.1007/978-1-0716-5158-2_19
Bacci, M., Cancellara, A., Ciceri, R., Romualdi, E., Pessi, V., Tumminello, F., Fantuzzi, M., Donadini, M. P., Lodigiani, C., Bella, S. D., et al. (2023) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.10167952
Metadata
- Authors
- Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., Frelinger, A. L., & Ingber, D. E.
- Affiliations
- Boston Children's Hospital (US)
- Harvard University (US)
- Cedars-Sinai Medical Center (US)
- Carnegie Mellon University (US)
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Ingber, Donald E.
- ORCID
- Venue
- Biomedical Microdevices
- Published
- 2016-07-27
- Volume
- 18
- Issue
- 4
- Pages
- 73-73
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- PMC
- PMC4963439
- OpenAlex
- W2501166177
- Cited by
- 148
- References
- 32
- Citations by year
- 2026: 9 · 2025: 10 · 2024: 18 · 2023: 12 · 2022: 11 · 2021: 22 · 2020: 17 · 2019: 15 · 2018: 17 · 2017: 15 · 2016: 1
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Biomedical Microdevices (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- University of Twente Research Information (submittedVersion, cc-by)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- Defense Advanced Research Projects Agency (N66001-11-1-4180, HR0011-13-C-0025)
- Janssen Pharmaceuticals
- Topics
- Health Sciences › Medicine › Hematology › Platelet Disorders and Treatments
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- microfluidics, platelet function, shear stress, hemostasis, platelet-rich thrombus, antiplatelet agents, point-of-care testing
- MeSH terms
- Blood Platelets, Endothelium, Vascular, Fibrin, Humans, Platelet Aggregation Inhibitors, Stress, Mechanical, Thrombosis, Point-of-Care Systems, Endothelial Cells, Lab-On-A-Chip Devices, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.