Microneedles: materials, fabrication, and biomedical applications
Open accessThe DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Abstract
The microneedles have attracted great interests for a wide range of transdermal biomedical applications, such as biosensing and drug delivery, due to the advantages of being painless, semi-invasive, and sustainable. The ongoing challenges are the materials and fabrication methods of the microneedles in order to obtain a specific shape, configuration and function of the microneedles to achieve a target biomedical application. Here, this review would introduce the types of materials of the microneedles firstly. The hardness, Young's modulus, geometric structure, processability, biocompatibility and degradability of the microneedles are explored as well. Then, the fabrication methods for the solid and hollow microneedles in recent years are reviewed in detail, and the advantages and disadvantages of each process are analyzed and compared. Finally, the biomedical applications of the microneedles are reviewed, including biosensing, drug delivery, body fluid extraction, and nerve stimulation. It is expected that this work provides the fundamental knowledge for developing new microneedle devices, as well as the applications in a variety of biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517 · cited 1×
“For drug administration, the microneedle approach has the advantages of avoiding the effect of the gastrointestinal digestion, accelerating the drug absorption, prolonging the effective time, and patient self-administered without needing doctors (Prausnitz and Langer 2008).”
BackgroundLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Cellulose and its derivatives: towards biomedical applications
Seddiqi, H., Oliaei, E., Honarkar, H., Jin, J., Geonzon, L. C., Bacabac, R. G., & Klein-Nulend, J. (2021) · Cellulose · doi:10.1007/s10570-020-03674-w · Cited by 1,167
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026 · cited 1×
“The microneedle materials can be silicon (Park et al. 2005), metals, biomaterials, and polymers (Lee et al. 2016a; van der Maaden et al. 2012).”
BackgroundMicroneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604 · cited 2×
“a A glucose-responsive insulin patch for regulating blood glucose (Yu et al. 2020).”
BackgroundTransdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530 · cited 1×
“This product has been approved by the U.S. FDA for use in influenza vaccination (Jacoby et al. 2015).”
Rapidly separable microneedle patch for the sustained release of a contraceptive
Li, W., Terry, R. N., Tang, J., Feng, M. R., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0337-4 · Cited by 492
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477 · cited 3×
“But the preparation of hollow microneedles is cumbersome and difficult, and the tissue can create resistance to the microneedle injection (Ma and Wu 2017; Carcamo-Martinez et al. 2021).”
BackgroundMethod
Cited by
Current advancements in microneedle technology for therapeutic and biomedical applications
Sen, O., Poddar, P., Sarkar, P., Das, S., & Manna, S. (2025) · Sensors International · doi:10.1016/j.sintl.2024.100325 · Cited by 39
Metadata
- Authors
- Luo, X., Yang, L., & Cui, Y.
- Venue
- Biomedical Microdevices
- Published
- 2023-06-06
- Volume
- 25
- Issue
- 3
- Pages
- 20-20
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W4379509210
- Cited by
- 219
- References
- 138
- FWCI
- 18.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.