Microneedles: materials, fabrication, and biomedical applications
Open accessThe DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Abstract
The microneedles have attracted great interests for a wide range of transdermal biomedical applications, such as biosensing and drug delivery, due to the advantages of being painless, semi-invasive, and sustainable. The ongoing challenges are the materials and fabrication methods of the microneedles in order to obtain a specific shape, configuration and function of the microneedles to achieve a target biomedical application. Here, this review would introduce the types of materials of the microneedles firstly. The hardness, Young's modulus, geometric structure, processability, biocompatibility and degradability of the microneedles are explored as well. Then, the fabrication methods for the solid and hollow microneedles in recent years are reviewed in detail, and the advantages and disadvantages of each process are analyzed and compared. Finally, the biomedical applications of the microneedles are reviewed, including biosensing, drug delivery, body fluid extraction, and nerve stimulation. It is expected that this work provides the fundamental knowledge for developing new microneedle devices, as well as the applications in a variety of biomedical fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517 · cited 1×
“For drug administration, the microneedle approach has the advantages of avoiding the effect of the gastrointestinal digestion, accelerating the drug absorption, prolonging the effective time, and patient self-administered without needing doctors (Prausnitz and Langer 2008).”
BackgroundLee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Cellulose and its derivatives: towards biomedical applications
Seddiqi, H., Oliaei, E., Honarkar, H., Jin, J., Geonzon, L. C., Bacabac, R. G., & Klein-Nulend, J. (2021) · Cellulose · doi:10.1007/s10570-020-03674-w · Cited by 1,167
Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026 · cited 1×
“The microneedle materials can be silicon (Park et al. 2005), metals, biomaterials, and polymers (Lee et al. 2016a; van der Maaden et al. 2012).”
BackgroundMicroneedle technologies for (trans)dermal drug and vaccine delivery
van der Maaden, K., Jiskoot, W., & Bouwstra, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.042 · Cited by 651
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604 · cited 2×
“a A glucose-responsive insulin patch for regulating blood glucose (Yu et al. 2020).”
BackgroundTransdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530 · cited 1×
“This product has been approved by the U.S. FDA for use in influenza vaccination (Jacoby et al. 2015).”
Rapidly separable microneedle patch for the sustained release of a contraceptive
Li, W., Terry, R. N., Tang, J., Feng, M. R., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0337-4 · Cited by 492
Microneedle, bio-microneedle and bio-inspired microneedle: A review
Ma, G., & Wu, C. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.011 · Cited by 477 · cited 3×
“But the preparation of hollow microneedles is cumbersome and difficult, and the tissue can create resistance to the microneedle injection (Ma and Wu 2017; Carcamo-Martinez et al. 2021).”
BackgroundMethodRouphael, N. G., Paine, M., Mosley, R., Henry, S., McAllister, D. V., Kalluri, H., Pewin, W., Frew, P. M., Yu, T., Thornburg, N. J., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30575-5 · Cited by 442
Microneedle for transdermal drug delivery: current trends and fabrication
Jung, J. H., & Jin, S. G. (2021) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-021-00512-4 · Cited by 416
Recent advances of microneedles for biomedical applications: drug delivery and beyond
Yang, J., Liu, X., Fu, Y., & Song, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.03.007 · Cited by 378
Han, D., Morde, R. S., Mariani, S., La Mattina, A. A., Vignali, E., Yang, C., Barillaro, G., & Lee, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909197 · Cited by 360 · cited 2×
“The tissue adhesion of barbed microneedle was 18 times that of non-barbed microneedle, and the tissue adhesion of biologically inspired microneedle had been improved (Han et al. 2020).”
Biodegradable 3D printed polymer microneedles for transdermal drug delivery
Luzuriaga, M. A., Berry, D. R., Reagan, J. C., Smaldone, R. A., & Gassensmith, J. J. (2018) · Lab on a Chip · doi:10.1039/c8lc00098k · Cited by 356 · cited 1×
“…PLA solid microneedles, and then etched the microneedles in KOH solution, reducing the thickness and width to 200-300 μm, and the tip size was Between 1-55 μm, it improves the feature size resolution of FDM printed materials and has considerable mechanical strength (Luzuriaga et al. 2018).”
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01127 · Cited by 354 · cited 1×
“The project began in November 2022 and tested the accuracy, tolerability, and safety of the device in patients with Parkinson's disease (Goud et al. 2019).”
MethodDroplet-born air blowing: Novel dissolving microneedle fabrication
Kim, J. D., Kim, M., Yang, H., Lee, K., & Jung, H. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.05.026 · Cited by 326
Krieger, K. J., Bertollo, N., Dangol, M., Sheridan, J. T., Lowery, M. M., & O’Cearbhaill, E. D. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0088-8 · Cited by 325
3D printed microneedle patches using stereolithography (SLA) for intradermal insulin delivery
Economidou, S. N., Pere, C. P. P., Reid, A., Uddin, M. J., Windmill, J. F. C., Lamprou, D. A., & Douroumis, D. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.063 · Cited by 311 · cited 1×
“Compared with metal MN, 3D printed polymer MN requires less force to penetrate pig skin (Economidou et al. 2019).”
BackgroundLab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310 · cited 1×
“…body reactions that affect the long-term operation of the sensor in humans, among other limiting issues, and microneedle sensors require ultra-sensitive responses to monitor trace levels of many important target molecules and accurately quantify analyte concentrations (Teymourian et al. 2021).”
BackgroundDissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011) · Small · doi:10.1002/smll.201001091 · Cited by 301
Bhatnagar, S., Dave, K., & Venuganti, V. V. K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.029 · Cited by 297 · cited 1×
“Numerous clinical trials aimed at investigating the safety and efficacy of microneedle-based systems are ongoing (Bhatnagar et al. 2017).”
BackgroundHollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285 · cited 1×
“But the preparation of hollow microneedles is cumbersome and difficult, and the tissue can create resistance to the microneedle injection (Ma and Wu 2017; Carcamo-Martinez et al. 2021).”
BackgroundContinuous minimally-invasive alcohol monitoring using microneedle sensor arrays
Mohan, A. M. V., Windmiller, J. R., Mishra, R. K., & Wang, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.016 · Cited by 274
Microneedle-based biosensor for minimally-invasive lactate detection
Bollella, P., Sharma, S., Cass, A. E. G., & Antiochia, R. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.010 · Cited by 267 · cited 2×
“The sensor showed the excellent performances in artificial interstitial fluid and human serum (Bollella et al. 2019b).”
BackgroundInfluentialTransdermal electroosmotic flow generated by a porous microneedle array patch
Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M. (2021) · Nature Communications · doi:10.1038/s41467-021-20948-4 · Cited by 260 · cited 1×
“12b, Shinya Kusama's group developed a porous microneedle array patch, and an enhanced transdermal drug delivery and glucose extraction can be obtained by applying a DC to the pig skin samples (Kusama et al. 2021).”
BackgroundTwo Photon Polymerization of Polymer–Ceramic Hybrid Materials for Transdermal Drug Delivery
Ovsianikov, A., Chichkov, B., Mente, P., Monteiro‐Riviere, N. A., Doraiswamy, A., & Narayan, R. J. (2007) · International Journal of Applied Ceramic Technology · doi:10.1111/j.1744-7402.2007.02115.x · Cited by 259
Metal microneedle fabrication using twisted light with spin
Omatsu, T., Chujo, K., Miyamoto, K., Okida, M., Nakamura, K., Aoki, N., & Morita, R. (2010) · Optics Express · doi:10.1364/oe.18.017967 · Cited by 259 · cited 2×
“c a laser ablation for fabricating the microneedles on metal surfaces that uses distorted light to rotate (Omatsu et al. 2010)”
MethodA Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901201 · Cited by 257 · cited 7×
“…can also be combined with optimization of skin preparation, such (Li et al. 2012). b A hydrogel microneedle patch for detecting interstitial fluid (He et al. 2020). c The hydrogel patch is integrated with an electronic glucose sensor for rapid extraction of microliter skin interstitial fluid…”
BackgroundMethodInfluentialA review on 3D printed matrix polymer composites: its potential and future challenges
Saroia, J., Wang, Y., Wei, Q., Lei, M., Li, X., Guo, Y., & Zhang, K. (2020) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-019-04534-z · Cited by 253 · cited 2×
“a Polymer microneedles by SLA laser (Saroia et al. 2020).”
Method3D printed microneedles for anticancer therapy of skin tumours
Uddin, M. J., Scoutaris, N., Economidou, S. N., Giraud, C., Chowdhry, B. Z., Donnelly, R. F., & Douroumis, D. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.110248 · Cited by 247
Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
Mishra, R. K., Goud, K. Y., Li, Z., Moonla, C., Mohamed, M. A., Tehrani, F., Teymourian, H., & Wang, J. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c01883 · Cited by 238 · cited 2×
“Mishra et al. prepared a wearable microneedle sensor array, which can be used to detect opioid drugs (OPI) and organophosphate (OP) nerve agents and can be applied to rapid human body induction (Mishra et al. 2020).”
BackgroundMicroneedle-based device for the one-step painless collection of capillary blood samples
Blicharz, T. M., Gong, P., Bunner, B. M., Chu, L. L., Leonard, K. M., Wakefield, J. A., Williams, R. E., Dadgar, M., Tagliabue, C. A., El Khaja, R., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0194-1 · Cited by 216 · cited 1×
“The clinical studies have shown that the pain from the blood collection by the device is significantly less than that associated with the venipuncture (Blicharz et al. 2018).”
BackgroundZheng, M., Wang, Z., Chang, H., Wang, L., Chew, S. W. T., Lio, D. C. S., Cui, M., Liu, L., Tee, B. C. K., & Xu, C. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901683 · Cited by 207 · cited 3×
“c The hydrogel patch is integrated with an electronic glucose sensor for rapid extraction of microliter skin interstitial fluid (Zheng et al. 2020).”
MethodInfluentialThe effects of geometry on skin penetration and failure of polymer microneedles
Gittard, S. D., Chen, B., Xu, H., Ovsianikov, A., Chichkov, B. N., Monteiro-Riviere, N. A., & Narayan, R. J. (2012) · Journal of Adhesion Science and Technology · doi:10.1080/01694243.2012.705101 · Cited by 204 · cited 2×
“used the microneedles made from acrylate-based polymer e-shell 200 and tested their geometry to study the microneedle mechanical failure mode and the mechanism of penetrating pigskin (Gittard et al. 2013).”
BackgroundMethodMicroneedle Coating Techniques for Transdermal Drug Delivery
Haj‐Ahmad, R., Khan, H., Arshad, M. S., Rasekh, M., Hussain, A., Walsh, S. E., Li, X., Chang, M., & Ahmad, Z. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040486 · Cited by 203 · cited 2×
“coating processes such as changing the flow rate and applying voltage, controlled deposition of particles (100 nm to 3 μm) and fibers (400 nm to 1 μm) on MNs can be controlled directly (Haj-Ahmad et al. 2015; Khan et al. 2014).”
BackgroundVora, L. K., Courtenay, A. J., Tekko, I. A., Larrañeta, E., & Donnelly, R. F. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.12.184 · Cited by 195 · cited 1×
“Microneedle scalp administration has a wide range of applications in insulin administration (Vora et al. 2020; Yu et al. 2020; Kim et al. 2020a; Darvishha and Amiri 2019), as shown in Fig.”
BackgroundMicroneedle-based self-powered glucose sensor
Valdés-Ramírez, G., Li, Y.-C., Kim, J., Jia, W., Bandodkar, A. J., Nuñez-Flores, R., Miller, P. R., Wu, S.-Y., Narayan, R., Windmiller, J. R., et al. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.07.014 · Cited by 188
Drawing lithography for microneedles: A review of fundamentals and biomedical applications
Lee, K., & Jung, H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.06.065 · Cited by 185 · cited 1×
“8c, Lee, K, et al. proposed three drawing techniques of continuous drawing of UHAR hollow microneedles, step-controlled drawing of dissolving microneedles and reverse isolation drawing of folded edges (Lee and Jung 2012).”
BackgroundRibet, F., Stemme, G., & Roxhed, N. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0349-6 · Cited by 181
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Lim, S. H., Ng, J. Y., & Kang, L. (2017) · Biofabrication · doi:10.1088/1758-5090/9/1/015010 · Cited by 168 · cited 2×
“used additive manufacturing (AM) technology to build a rugged microneedle physical model with geometrical complexity up to the micron level and printed layer by layer until manufacturing is completed (Lim et al. 2017).”
MethodPérennès, F., Marmiroli, B., Matteucci, M., Tormen, M., Vaccari, L., & Fabrizio, E. D. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/3/001 · Cited by 168 · cited 2×
“The work of Perennes was to produce PMMA through dual deep x-ray lithography, then combining with the imprint technology, to prepared PMMA microneedle (Perennes et al. 2006).”
BackgroundMethodMicromolding for ceramic microneedle arrays
Bystrova, S., & Lüttge, R. (2010) · Microelectronic Engineering · doi:10.1016/j.mee.2010.12.067 · Cited by 167 · cited 2×
“In addition to silicon, inorganic materials that can be used for microneedles include glass, glassy carbon (Mishra et al. 2018a), and ceramics (Bystrova and Luttge 2011; Hartmann et al. 2015; Verhoeven et al. 2012; Gholami et al. 2019), as shown in Fig.”
BackgroundMethodAnalgesic Microneedle Patch for Neuropathic Pain Therapy
Xie, X., Pascual, C., Lieu, C., Oh, S., Wang, J., Zou, B., Xie, J., Li, Z., Xie, J., Yeomans, D. C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06104 · Cited by 166
Li, J., Liu, B., Zhou, Y., Chen, Z., Jiang, L., Yuan, W., & Liang, L. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172043 · Cited by 166 · cited 10×
“Several types of materials have been studied, such as resin, nylon, ABS, and PLA.”
BackgroundInfluentialHigh-fidelity replication of thermoplastic microneedles with open microfluidic channels
Rad, Z. F., Nordon, R. E., Anthony, C., Bilston, L. E., Prewett, P. D., Arns, J., Arns, C. H., Zhang, L., & Davies, G. J. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.34 · Cited by 160
Gowers, S. A. N., Freeman, D. M. E., Rawson, T. M., Rogers, M. L., Wilson, R. C., Holmes, A. H., Cass, A. E., & O’Hare, D. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00288 · Cited by 159 · cited 2×
“The ability of these biosensors to track penicillin concentrations in the body in real time has been demonstrated in trials with healthy volunteers (Gowers et al. 2019).”
BackgroundA microneedle platform for buccal macromolecule delivery
Caffarel-Salvador, E., Kim, S., Soares, V., Tian, R. Y., Stern, S. R., Minahan, D., Yona, R., Lu, X., Zakaria, F. R., Collins, J., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe2620 · Cited by 152 · cited 3×
“13e, and collected the skin interstitial fluid into the paper reservoir on the patch, obtaining 2.9 μl interstitial fluid in 30 s (Kim et al. 2021).”
BackgroundMethodInfluential3D Printed Multi-Functional Hydrogel Microneedles Based on High-Precision Digital Light Processing
Yao, W., Li, D., Zhao, Y., Zhan, Z., Jin, G., Liang, H., & Yang, R. (2019) · Micromachines · doi:10.3390/mi11010017 · Cited by 146 · cited 2×
“proposed the hydrogel MNs based on DLP 3D printing, studied the mechanical properties of MNs in detail at different exposure times, and performed artificial skin microneedle puncture simulation, MNs injection, and extraction drug simulation experiments, and it shows that the microneedles prepared by DLP have good mech…”
MethodSolid silicon microneedles for drug delivery applications
Narayanan, S. P., & Raghavan, S. (2016) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-016-9698-6 · Cited by 144 · cited 1×
“The general length of silicon microneedles is 150~1700 μm and the needle pitch is 260~2000 μm (Pradeep Narayanan and Raghavan 2017).”
BackgroundPolymeric microneedle fabrication using a microinjection molding technique
Sammoura, F., Kang, J.-J., Heo, Y.-M., Jung, T., & Lin, L. (2006) · Microsystem Technologies · doi:10.1007/s00542-006-0204-1 · Cited by 143 · cited 1×
“For the micro-injection, the solution was injected into the cavities of the mold with a micro-injector by a compression process (Sammoura et al. 2007; O'Mahony et al. 2019; Mirza et al. (2017)).”
MethodBolton, C., Howells, O., Blayney, G. J., Eng, P. F., Birchall, J. C., Gualeni, B., Roberts, K., Ashraf, H., & Guy, O. J. (2020) · Lab on a Chip · doi:10.1039/d0lc00567c · Cited by 141 · cited 2×
“For example, Bolton et al. developed a novel dry plasma processing to prepare the hollow microneedles with the beveled tips and vertical sidewalls with a good uniformity, which successfully injected insulin into porcine skin (Bolton et al. 2020).”
BackgroundYang, B., Fang, X., & Kong, J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000591 · Cited by 138 · cited 6×
“…using ion electrophoresis double extraction for rapid capture and detection of Epstein Barr virus cell-free DNA (Yang et al. 2020) 20 Page 18 of 29 was successfully extracted from interstitial fluid within 10 min, and the maximum capture efficiency was 95.4% (Yang et al. 2020), as shown in Fig.”
MethodInfluentialTrautmann, A., Roth, G., Nujiqi, B., Walther, T., & Hellmann, R. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0046-5 · Cited by 130
Bicomponent Microneedle Array Biosensor for Minimally‐Invasive Glutamate Monitoring
Windmiller, J. R., Valdés‐Ramírez, G., Zhou, N., Zhou, M., Miller, P. R., Jin, C., Brozik, S. M., Polsky, R., Katz, E., Narayan, R., et al. (2011) · Electroanalysis · doi:10.1002/elan.201100361 · Cited by 129
Gupta, J., Felner, E. I., & Prausnitz, M. R. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0204 · Cited by 128
Zheng, Y., Omar, R., Zhang, R., Tang, N., Khatib, M., Xu, Q., Milyutin, Y., Saliba, W., Broza, Y. Y., Wu, W., et al. (2021) · Advanced Materials · doi:10.1002/adma.202108607 · Cited by 122
Bollella, P., Sharma, S., Cass, A. E. G., Tasca, F., & Antiochia, R. (2019) · Catalysts · doi:10.3390/catal9070580 · Cited by 121 · cited 1×
“It showed an excellent sensitivity (50.86 μA cm −2 mM −1 ), a high stability (20% signal loss after 30 days), and a short response time (3 s) (Bollella et al. 2019a).”
BackgroundInfluentialCahill, E. M., Keaveney, S., Stuettgen, V., Eberts, P. M., Ramos-Luna, P., Zhang, N., Dangol, M., & O’Cearbhaill, E. D. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.09.007 · Cited by 121 · cited 2×
“The metal microneedles include stainless steel (Cahill et al. 2018), titanium (Skoog et al. 2015), aluminum, and Ni (Chen et al. 2019).”
BackgroundLi, J., Zhou, Y., Yang, J., Ye, R., Gao, J., Ren, L., Liu, B., Liang, L., & Jiang, L. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.11.074 · Cited by 118 · cited 2×
“5b (Li et al. 2019a).”
MethodMicromachined needles for the transdermal delivery of drugs
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1998.659807 · Cited by 117 · cited 1×
“The manufacturing process is by using photolithography to obtain a microsized pattern, followed by the deposition of metals, such as chromium as a mask material layer (Henry et al. 1998).”
MethodKim, S., Yang, H., Eum, J., Ma, Y., Lahiji, S. F., & Jung, H. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119733 · Cited by 116 · cited 6×
“The addition of hydrogel enables the microneedles to have the continuous drug delivery capabilities and can be used in various applications that require the sustained release of drugs for several days (Kim et al. 2020b).”
BackgroundMethodInfluentialAhmed, K. S., Shan, X., Mao, J. Y., Qiu, L., & Chen, J. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.02.095 · Cited by 116 · cited 2×
“The metal microneedles include stainless steel (Cahill et al. 2018), titanium (Skoog et al. 2015), aluminum, and Ni (Chen et al. 2019).”
BackgroundRecent progress of 3D-printed microneedles for transdermal drug delivery
Yang, Q., Zhong, W., Xu, L., Li, H., Yan, Q., She, Y., & Yang, G. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.120106 · Cited by 113 · cited 1×
“Most of the published reviews on microneedles mainly reviewed the application of microneedles in drug delivery (Ita 2015; Yang et al. 2019, 2021).”
BackgroundA Photolithographic Approach to Polymeric Microneedles Array Fabrication
Dardano, P., Caliò, A., Palma, V. D., Bevilacqua, M., Matteo, A. D., & Stefano, L. D. (2015) · Materials · doi:10.3390/ma8125484 · Cited by 113 · cited 1×
“…using the type II process (Held et al. 2010). c A lithography process sketch (not to scale) for manufacturing micro needles (MNS) by method 1 and method 2 (Dardano et al. 2015) 20 Page 8 of 29 multiple inclined surfaces is prepared, which is more conducive to piercing the skin and reducing pain.”
MethodZhao, Z., Chen, Y., & Shi, Y. (2020) · RSC Advances · doi:10.1039/d0ra00735h · Cited by 106
Bok, M., Zhao, Z., Jeon, S., Jeong, J., & Lim, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-58822-w · Cited by 106 · cited 2×
“studied to enhance the permeability of hydrogels and drugs by a ultrasonic sound pressure and an AC iontophoresis with the hyaluronic acid microneedles (Bok et al. 2020).”
BackgroundLuo, X., Yu, Q., Liu, Y., Gai, W., Ye, L., Yang, L., & Cui, Y. (2022) · ACS Sensors · doi:10.1021/acssensors.1c02337 · Cited by 103
Self-citationGholami, S., Mohebi, M. M., Hajizadeh‐Saffar, E., Ghanian, M. H., Zarkesh, I., & Baharvand, H. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.12.089 · Cited by 99 · cited 2×
“In addition to silicon, inorganic materials that can be used for microneedles include glass, glassy carbon (Mishra et al. 2018a), and ceramics (Bystrova and Luttge 2011; Hartmann et al. 2015; Verhoeven et al. 2012; Gholami et al. 2019), as shown in Fig.”
BackgroundA hollow stainless steel microneedle array to deliver insulin to a diabetic rat
Vinayakumar, K. B., Kulkarni, P. G., Nayak, M. M., Dinesh, N. S., Hegde, G., Ramachandra, S. G., & Rajanna, K. (2016) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/6/065013 · Cited by 97
Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S., & Allen, M. G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.013 · Cited by 96 · cited 1×
“3a (Lee et al. 2016b; Yan et al. 2018).”
Rapid paper based colorimetric detection of glucose using a hollow microneedle device
Nicholas, D., Logan, K. A., Sheng, Y., Gao, J., Farrell, S., Dixon, D., Callan, B., McHale, A. P., & Callan, J. F. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.06.002 · Cited by 96 · cited 1×
“For the manufacture of hollow structures, Nicholas and others' work is using a hypodermic needle to insert into the mold to form a hollow tube during 3D printing (Nicholas et al. 2018).”
MethodPlasmonic Paper Microneedle Patch for On-Patch Detection of Molecules in Dermal Interstitial Fluid
Kolluru, C., Gupta, R., Jiang, Q., Williams, M., Derami, H. G., Cao, S., Noel, R. K., Singamaneni, S., & Prausnitz, M. R. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00258 · Cited by 93 · cited 2×
“…skin interstitial fluid (Zheng et al. 2020). d A microneedle patch based on plasma paper for molecular detection in dermal interstitial fluid (Kolluru et al. 2019). e The 3D printing device for interstitial fluid extraction with inclined microneedle penetration (Kim et al. 2021) as…”
BackgroundMethodThakur, R. R. S., Fallows, S. J., McMillan, H. L., Donnelly, R. F., & Jones, D. S. (2013) · Journal of Pharmacy and Pharmacology · doi:10.1111/jphp.12152 · Cited by 93 · cited 1×
“delivered a thermoresponsive orthotopic implant forming poloxamer formulation into scleral tissue, and the sustained drug delivery could be accomplished by changing the needle penetration depth, the implant gel composition, and the area injected intrasclerally (Thakur et al. 2014).”
BackgroundZhang, Y., Wang, D., Gao, M., Xu, B., Zhu, J., Yu, W., Liu, D., & Jiang, G. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00642 · Cited by 91 · cited 3×
“used PLC microneedles that can be degraded by light heating, thereby releasing the loaded metformin (Zhang et al. 2018).”
BackgroundMethodInfluentialHowells, O., Blayney, G. J., Gualeni, B., Birchall, J. C., Eng, P. F., Ashraf, H., Sharma, S., & Guy, O. J. (2021) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2021.06.005 · Cited by 91 · cited 1×
“The processing technologies of the silicon and silicon-based materials have been very mature, such as laser technology, etching technology, and laser cutting (Jung and Jin 2021) (Howells et al. 2022).”
MethodLiu, D., Yu, B., Jiang, G., Yu, W., Zhang, Y., & Xu, B. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.04.055 · Cited by 90 · cited 7×
“Compared with pure PVP microneedles, CaCO3 doped PVP microneedles show a high mechanical strength (Liu et al. 2018).”
BackgroundInfluentialPoly (vinyl alcohol)/chitosan layer-by-layer microneedles for cancer chemo-photothermal therapy
Moreira, A. F., Rodrigues, C. F., Jacinto, T. A., Miguel, S. P., Costa, E. C., & Correia, I. J. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118907 · Cited by 90 · cited 1×
“The microneedle administration can enhance the penetration efficiency of small molecule drugs (Gui et al. 2017; Wu et al. 2016; Cao et al. 2016; Moreira et al. 2020; Gao et al. 2019; Ahmed et al. 2019).”
BackgroundYang, H., Kim, S., Kang, G., Lahiji, S. F., Jang, M., Kim, Y. M., Kim, J., Cho, S., & Jung, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700326 · Cited by 89 · cited 3×
“The specific methods are: 1) the polymer droplets were placed on an inner plate, and an outer parallel plate is not in contact with the droplets; 2) by rotating, the effect of a centrifugal force is distributed in the axial direction of a polymer droplet; 3) with the rotation, the head of the droplet rises and necks u…”
BackgroundMethodInfluentialRemotely triggered release of small molecules from LaB6@SiO2-loaded polycaprolactone microneedles
Chen, M., Wang, K., Chen, D., Ling, M.-H., & Liu, C.-Y. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.11.040 · Cited by 88
Porous polymer coatings on metal microneedles for enhanced drug delivery
Ullah, A., Kim, C. M., & Kim, G. M. (2018) · Royal Society Open Science · doi:10.1098/rsos.171609 · Cited by 88 · cited 6×
“EHDA can form a uniform particle coating on the surface of MNs with a coating efficiency of 30%, and mechanical properties and Insertion performance are not much different from uncoated (Angkawinitwong et al. 2020).”
BackgroundInfluentialKim, M. J., Park, S., Rizal, B., Guanes, G., Baek, S., Park, J., Betz, A. R., & Choi, S. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00054 · Cited by 87
A novel fabrication method of a microneedle array using inclined deep x-ray exposure
Moon, S. J., & Lee, S. S. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/5/002 · Cited by 84
Narayanan, S. P., & Raghavan, S. (2018) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-018-2596-3 · Cited by 81 · cited 2×
“The calculated mechanical strength is 37.27 GPa, which is higher than the skin's resistance (Narayanan and Raghavan 2019).”
BackgroundInfluentialOpportunities and challenges in delivering influenza vaccine by microneedle patch
Jacoby, E., Jarrahian, C., Hull, H. F., & Zehrung, D. (2015) · Vaccine · doi:10.1016/j.vaccine.2015.03.062 · Cited by 77
Fenestrated microneedles for ocular drug delivery
Khandan, O., Kahook, M. Y., & Rao, M. P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.09.071 · Cited by 77
Angkawinitwong, U., Courtenay, A. J., Rodgers, A. M., Larrañeta, E., McCarthy, H. O., Brocchini, S., Donnelly, R. F., & Williams, G. R. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22425 · Cited by 76 · cited 2×
“EHDA can form a uniform particle coating on the surface of MNs with a coating efficiency of 30%, and mechanical properties and Insertion performance are not much different from uncoated (Angkawinitwong et al. 2020).”
BackgroundMethodVerhoeven, M., Bystrova, S., Winnubst, L. A. J. A., Qureshi, H. F., de Gruijl, T. D., Scheper, R. J., & Lüttge, R. (2012) · Microelectronic Engineering · doi:10.1016/j.mee.2012.07.022 · Cited by 70 · cited 1×
“In addition to silicon, inorganic materials that can be used for microneedles include glass, glassy carbon (Mishra et al. 2018a), and ceramics (Bystrova and Luttge 2011; Hartmann et al. 2015; Verhoeven et al. 2012; Gholami et al. 2019), as shown in Fig.”
BackgroundNitrogen-incorporated ultrananocrystalline diamond microneedle arrays for electrochemical biosensing
Skoog, S. A., Miller, P. R., Boehm, R. D., Sumant, A. V., Polsky, R., & Narayan, R. J. (2014) · Diamond and Related Materials · doi:10.1016/j.diamond.2014.11.016 · Cited by 69
Chen, M., Chan, H.-A., Ling, M.-H., & Su, L.-C. (2017) · Journal of Materials Chemistry B · doi:10.1039/c6tb02718k · Cited by 66 · cited 3×
“Microneedles have attracted increasing interest in recent years in biomedical areas, such as drug delivery, biosensing, and fluid extraction (Chen et al. 2017).”
BackgroundMethodInfluentialIn Vivo Experimental Study of Noninvasive Insulin Microinjection through Hollow Si Microneedle Array
Resnik, D., Možek, M., Pečar, B., Janež, A., Urbančič, V., Iliescu, C., & Vrtačnik, D. (2018) · Micromachines · doi:10.3390/mi9010040 · Cited by 65 · cited 1×
“%) was observed, mainly attributing to a more efficient delivery of insulin at a high insulin (200 IU/ml) by hollow microneedles (Resnik et al. 2018).”
BackgroundFabrication and characterization of gold coated hollow silicon microneedle array for drug delivery
Vinayakumar, K. B., Hegde, G. M., Nayak, M. M., Dinesh, N. S., & Rajanna, K. (2014) · Microelectronic Engineering · doi:10.1016/j.mee.2014.05.039 · Cited by 64 · cited 1×
“The silicon and silicon-based materials are also widely used in the microneedle drug delivery systems, which are mainly prepared by a combination of isotropic and anisotropic corrosion processes (Vinayakumar et al. 2014; Khanna et al. 2010).”
BackgroundSmart microneedle coatings for controlled delivery and biomedical analysis
Khan, H., Mehta, P., Msallam, H., Armitage, D., & Ahmad, Z. (2014) · Journal of drug targeting · doi:10.3109/1061186x.2014.921926 · Cited by 63
Nayak, A., Das, D. B., & Vladisavljević, G. T. (2013) · Pharmaceutical Research · doi:10.1007/s11095-013-1240-z · Cited by 62
Liu, P., Du, H., Chen, Y., Wang, H., Mao, J., Zhang, L., Tao, J., & Zhu, J. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02837d · Cited by 62 · cited 1×
“The blood glucose level of the mouse dropped to normal levels within 8 h after the drug administration (Liu et al. 2020).”
BackgroundKundu, A., Ausaf, T., & Rajaraman, S. (2018) · Micromachines · doi:10.3390/mi9020085 · Cited by 60 · cited 1×
“Kundu proposed an inexpensive micromachining technique that uses micro drills or laser micromachining to obtain feature subtractive printing for the preparation of hollow microneedles (Kundu et al. 2018).”
MethodLi, C. G., Lee, K., Lee, C. Y., Dangol, M., & Jung, H. (2012) · Advanced Materials · doi:10.1002/adma.201201109 · Cited by 58
Investigation of Plasma Treatment on Micro-Injection Moulded Microneedle for Drug Delivery
Nair, K. J., Whiteside, B. R., Grant, C. A., Patel, R., Tuinea-Bobe, C. L., Norris, K. C., & Paradkar, A. R. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040471 · Cited by 57 · cited 2×
“used a plasma technology and a micro-injection molding to prepare the surface-modified PC microneedles, which improved the surface energy and roughness of the PC materials (Nair et al. 2015).”
MethodBukhamsin, A., Moussi, K., Tao, R., Lubineau, G., Blilou, I., Salama, K. N., & Kosel, J. (2021) · Advanced Science · doi:10.1002/advs.202101261 · Cited by 56 · cited 3×
“…sensor patch based on hollow biodegradable microneedles (Luo et al. 2022). b A bioimpedance sensor based on microneedle for precision farming (Bukhamsin et al. 2021). c A extended gate transistor based on wearable microneedles for real-time detection of sodium in interstitial fluids (Zheng…”
BackgroundMethodInfluentialTwo-Photon Nanolithography of Tailored Hollow three-dimensional Microdevices for Biosystems
Liao, C., Anderson, W., Antaw, F., & Trau, M. (2019) · ACS Omega · doi:10.1021/acsomega.8b03164 · Cited by 55
Gao, Y., Hou, M., Yang, R., Zhang, L., Xu, Z., Kang, Y., & Xue, P. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01994d · Cited by 53 · cited 1×
“The microneedle administration can enhance the penetration efficiency of small molecule drugs (Gui et al. 2017; Wu et al. 2016; Cao et al. 2016; Moreira et al. 2020; Gao et al. 2019; Ahmed et al. 2019).”
BackgroundCao, Y., Tao, Y., Zhou, Y., & Gui, S. (2016) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2016.06.007 · Cited by 53 · cited 1×
“The microneedle administration can enhance the penetration efficiency of small molecule drugs (Gui et al. 2017; Wu et al. 2016; Cao et al. 2016; Moreira et al. 2020; Gao et al. 2019; Ahmed et al. 2019).”
BackgroundThermal ablation of separable microneedles for transdermal delivery of metformin on diabetic rats
Zhang, Y., Chai, D., Gao, M., Xu, B., & Jiang, G. (2018) · International Journal of Polymeric Materials · doi:10.1080/00914037.2018.1517347 · Cited by 52
Zhan, H., Ma, F., Huang, Y., Zhang, J., Jiang, X., & Qian, Y. (2018) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2018.06.014 · Cited by 49
Towards a minimally invasive device for beta-lactam monitoring in humans
Rawson, T. M., Sharma, S., Georgiou, P., Holmes, A. H., Cass, A. E. G., & O’Hare, D. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.07.011 · Cited by 48
Kim, K. B., Choi, H., Jung, H. J., Oh, Y., Cho, C.-H., Min, J. H., Yoon, S., Kim, J., Cho, S. J., & Chi, H. J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111622 · Cited by 48
Multiscale simulations of drug distributions in polymer dissolvable microneedles
Feng, Y. H., Liu, J. L., Zhu, D., Hao, Y. Y., & Guo, X. D. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.110844 · Cited by 48 · cited 8×
“PVA microneedles can be prepared by means of 3D printing (Uddin et al. 2020).”
BackgroundInfluentialKim, S., Lee, M. S., Yang, H. S., & Jung, J. H. (2021) · Scientific Reports · doi:10.1038/s41598-021-93235-3 · Cited by 44 · cited 3×
“13e, and collected the skin interstitial fluid into the paper reservoir on the patch, obtaining 2.9 μl interstitial fluid in 30 s (Kim et al. 2021).”
BackgroundMethodInfluentialFabrication and characterization of novel microneedles made of a polystyrene solution
Luangveera, W., Jiruedee, S., Mama, W., Chiaranairungroj, M., Pimpin, A., Palaga, T., & Srituravanich, W. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.06.009 · Cited by 42
Microneedles and transdermal drug delivery
Kalluri, H., & Banga, A. K. (2009) · Journal of Drug Delivery Science and Technology · doi:10.1016/s1773-2247(09)50065-2 · Cited by 41
Drug loaded biodegradable polymer microneedles fabricated by hot embossing
Andersen, T. E., Andersen, A. J., Petersen, R. S., Nielsen, L. H., & Keller, S. S. (2018) · Microelectronic Engineering · doi:10.1016/j.mee.2018.03.024 · Cited by 41
Mishra, R., Maiti, T. K., & Bhattacharyya, T. K. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aad301 · Cited by 40 · cited 3×
“In addition to silicon, inorganic materials that can be used for microneedles include glass, glassy carbon (Mishra et al. 2018a), and ceramics (Bystrova and Luttge 2011; Hartmann et al. 2015; Verhoeven et al. 2012; Gholami et al. 2019), as shown in Fig.”
BackgroundTemporal release of a three-component protein subunit vaccine from polymer multilayers
Uppu, D. S. S. M., Turvey, M. E., Sharif, A. R. M., Bidet, K., He, Y., Ho, V. C. Y., Tambe, A. D., Lescar, J., Tan, E. Y., Fink, K., et al. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.11.022 · Cited by 40
Study of the fabrication of AISI 316L microneedle arrays
García‐López, E., Siller, H. R., & Rodriguez, C. A. (2018) · Procedia Manufacturing · doi:10.1016/j.promfg.2018.07.014 · Cited by 39 · cited 2×
“However, this method would wear or even break the tool, and the production time is too long, making it economically unsuitable, and it is difficult to convert multi-step batch processing to high-throughput manufacturing scalability (Garcia-Lopez et al. 2018).”
MethodMolybdenum coated SU-8 microneedle electrodes for transcutaneous electrical nerve stimulation
Soltanzadeh, R., Afsharipour, E., Shafai, C., Anssari, N., Mansouri, B., & Moussavi, Z. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0241-9 · Cited by 38 · cited 1×
“The harmful Faraday current through the tissue is greatly reduced, which can reduce the pain of the user (Soltanzadeh et al. 2017).”
BackgroundRapoport, A. M., Ameri, M., Lewis, H., & Kellerman, D. J. (2020) · Pain Management · doi:10.2217/pmt-2020-0041 · Cited by 35 · cited 1×
“These products are undergoing clinical trials to evaluate their effects in patients (Rapoport et al. 2020; Friedman et al. 2021).”
BackgroundSinomenine hydrochloride-loaded dissolving microneedles enhanced its absorption in rabbits
Wu, X., Chen, Y., Gui, S., Wu, X., Chen, L., Cao, Y., Yin, D., & Ma, P. (2015) · Pharmaceutical Development and Technology · doi:10.3109/10837450.2015.1055766 · Cited by 31 · cited 1×
“The microneedle administration can enhance the penetration efficiency of small molecule drugs (Gui et al. 2017; Wu et al. 2016; Cao et al. 2016; Moreira et al. 2020; Gao et al. 2019; Ahmed et al. 2019).”
BackgroundFabrication of Hollow Metal Microneedle Arrays Using a Molding and Electroplating Method
Miller, P. R., Moorman, M. W., Boehm, R. D., Wolfley, S. L., Chavez, V. H., Baca, J. T., Ashley, C. E., Brener, I., Narayan, R. J., & Polsky, R. (2019) · MRS Advances · doi:10.1557/adv.2019.147 · Cited by 31 · cited 1×
“First, LDW and 2 pp were used to prepare solid microneedles with internal bosses, which were then formed using PDMS. Metal was then electroplated on the PDMS by pulse deposition to make metal hollow microneedles (Miller et al. 2019).”
MethodMeyer, B. K., Kendall, M. A. F., Williams, D. M., Bett, A. J., Dubey, S. A., Gentzel, R. C., Casimiro, D. R., Forster, A. H., Corbett, H. J., Crichton, M. L., et al. (2019) · Vaccine X · doi:10.1016/j.jvacx.2019.100030 · Cited by 31
Fabrication of Polymer Microneedle Electrodes Coated with Nanoporous Parylene
Nishinaka, Y., Jun, R., Prihandana, G. S., & Miki, N. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.06gl10 · Cited by 30
Held, J., Gaspar, J., Ruther, P., Hagner, M., Cismak, A., Heilmann, A. M. F., & Paul, O. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/2/025024 · Cited by 30 · cited 2×
“…as a function of the process parameters. b A schematic diagram of the combination of isotropic and anisotropic etching using the type II process (Held et al. 2010). c A lithography process sketch (not to scale) for manufacturing micro needles (MNS) by method 1 and method 2 (Dardano et al. 2015)…”
MethodAxial and shear fracture strength evaluation of silicon microneedles
Khanna, P., Luongo, K., Strom, J. A., & Bhansali, S. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1070-4 · Cited by 30 · cited 1×
“The silicon and silicon-based materials are also widely used in the microneedle drug delivery systems, which are mainly prepared by a combination of isotropic and anisotropic corrosion processes (Vinayakumar et al. 2014; Khanna et al. 2010).”
BackgroundHartmann, X., van der Linde, P., Homburg, E. F. G. A., Breemen, V. L. L., Jong, A. D., & Lüttge, R. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040503 · Cited by 30
Optimization Design and Fabrication of Polymer Micro Needle by Hot Embossing Method
Abubaker, S. S., & Zhang, Y. (2019) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-019-00095-z · Cited by 30 · cited 3×
“5a (Abubaker and Zhang 2019), and the coupling of the gradient thermal field and Page 11 of 29 20 the pressure field is the key to the process , as indicated in Fig.”
BackgroundMethodInfluentialCharacterisation of mechanical insertion of commercial microneedles
Sabri, A. H. B., Cater, Z., Ogilvie, J., Scurr, D. J., Marlow, M., & Segal, J. I. (2020) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2020.101766 · Cited by 28 · cited 1×
“Dermapen has been marketed worldwide and is widely used in the clinics of dermatologists (Sabri et al. 2020).”
BackgroundKamal, N. A. M., Mahmood, T. M. T., Ahmad, I. B., & Ramli, S. (2020) · Sains Malaysiana · doi:10.17576/jsm-2020-4909-24 · Cited by 27
PDMS embedded microneedles as a controlled release system for the eye
Mahadevan, G., Sheardown, H. D., & Selvaganapathy, P. R. (2012) · Journal of Biomaterials Applications · doi:10.1177/0885328211433778 · Cited by 26
(Trans) dermal insulin delivery based on polymeric systems
Darvishha, S., & Amiri, S. (2019) · International Journal of Polymeric Materials · doi:10.1080/00914037.2018.1534113 · Cited by 24 · cited 1×
“Microneedle scalp administration has a wide range of applications in insulin administration (Vora et al. 2020; Yu et al. 2020; Kim et al. 2020a; Darvishha and Amiri 2019), as shown in Fig.”
BackgroundDas, A., Singha, C., & Bhattacharyya, A. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2019.03.019 · Cited by 24 · cited 1×
“The structure includes cones, quadrangular pyramids, and triangular pyramid (Das et al. 2019).”
BackgroundArai, M., Masubuchi, S., Nose, K., Mitsuda, Y., & Machida, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.04dj06 · Cited by 23 · cited 1×
“Thus, the microneedles would not touch the nerve endings to further avoid bleeding and pain (Arai et al. 2015).”
BackgroundSkin penetration and fracture strength testing of silicon dioxide microneedles
Khanna, P., Flam, B. R., Osborn, B., Strom, J. A., & Bhansali, S. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.09.024 · Cited by 23 · cited 5×
“2 Silicon solid microneedles are prepared by the selective etching method. a A schematic diagram of isotropic etching using the type I and type II process and the profiles as a function of the process parameters. b A schematic diagram of the combination of isotropic and anisotropic etching using the type II process (H…”
BackgroundInfluentialDissolving Microneedles for Intradermal Vaccination against Shigellosis
Pastor, Y., Larrañeta, E., Erhard, Á., Quincoces, G., Peñuelas, I., Irache, J. M., Donnelly, R. F., & Gamazo, C. (2019) · Vaccines · doi:10.3390/vaccines7040159 · Cited by 21
Cell therapy using an array of ultrathin hollow microneedles
Iliescu, F. S., Teo, J. C. M., Vrtačnik, D., Taylor, H., & Iliescu, C. (2017) · Microsystem Technologies · doi:10.1007/s00542-017-3631-2 · Cited by 21
O’Mahony, C., Bocchino, A., Haslinger, M. J., Brandstätter, S., Außerhuber, H. M., Schossleitner, K., Clover, A. J. P., & Fechtig, D. J. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab222b · Cited by 13 · cited 1×
“For the micro-injection, the solution was injected into the cavities of the mold with a micro-injector by a compression process (Sammoura et al. 2007; O'Mahony et al. 2019; Mirza et al. (2017)).”
MethodGui, Z., Wu, X., Wang, S., Cao, Y., Wan, J., Shan, Q., Yang, Z., Zhang, J., & Gui, S. (2017) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2017.07.027 · Cited by 12 · cited 1×
“The microneedle administration can enhance the penetration efficiency of small molecule drugs (Gui et al. 2017; Wu et al. 2016; Cao et al. 2016; Moreira et al. 2020; Gao et al. 2019; Ahmed et al. 2019).”
BackgroundYan, X., Tang, G., Hu, R., Yang, B., Zhang, L., & Xu, B. S. (2018) · Sensors and Materials · doi:10.18494/sam.2018.1781 · Cited by 9 · cited 1×
“3a (Lee et al. 2016b; Yan et al. 2018).”
Soltanzadeh, R., Afsharipour, E., & Shafai, C. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3318 · Cited by 7
Cited by
Current advancements in microneedle technology for therapeutic and biomedical applications
Sen, O., Poddar, P., Sarkar, P., Das, S., & Manna, S. (2025) · Sensors International · doi:10.1016/j.sintl.2024.100325 · Cited by 39
Metadata
- Authors
- Luo, X., Yang, L., & Cui, Y.
- Venue
- Biomedical Microdevices
- Published
- 2023-06-06
- Volume
- 25
- Issue
- 3
- Pages
- 20-20
- ISSN
- 1387-2176 (ISSN-L)
- 1572-8781
- OpenAlex
- W4379509210
- Cited by
- 219
- References
- 138
- FWCI
- 18.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.