Effects of Forward Model Errors on EEG Source Localization
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Subject-specific four-layer boundary element method (BEM) electrical forward head models for four participants, generated from magnetic resonance (MR) head images using NFT (www.sccn.ucsd.edu/wiki/NFT), were used to simulate electroencephalographic (EEG) scalp potentials at 256 recorded electrode positions produced by single current dipoles of a 3-D grid in brain space. Locations of these dipoles were then estimated using gradient descent within five template head models fit to the electrode positions. These were: a spherical model, three-layer and four-layer BEM head models based on the Montreal Neurological Institute (MNI) template head image, and these BEM models warped to the recorded electrode positions. Smallest localization errors (4.1–6.2 mm, medians) were obtained using the electrode-position warped four-layer BEM models, with largest localization errors (~20 mm) for most basal brain locations. When we increased the brain-to-skull conductivity ratio assumed in the template model scalp projections from the simulated value (25:1) to a higher value (80:1) used in earlier studies, the estimated dipole locations moved outwards (12.4 mm, median). We also investigated the effects of errors in co-registering the electrode positions, of reducing electrode counts, and of adding a fifth, isotropic white matter layer to one individual head model. Results show that when individual subject MR head images are not available to construct subject-specific head models, accurate EEG source localization should employ a four- or five-layer BEM template head model incorporating an accurate skull conductivity estimate and warped to 64 or more accurately 3-D measured and co-registered electrode positions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Mining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493
Self-citationIndependent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Self-citationStatistical inverse problems: Discretization, model reduction and inverse crimes
Kaipio, J., & Somersalo, E. (2007) · Journal of Computational and Applied Mathematics · doi:10.1016/j.cam.2005.09.027 · Cited by 540
Current Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494 · cited 1×
“This value has been shown to be reliable across subjects (Baumann et al. 1997).”
BackgroundThe conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
Cited by
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Subcortical sources dominate the neuroelectric auditory frequency-following response to speech
Bidelman, G. M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.060 · Cited by 241
“While a template brain (as opposed to individual subject MRIs) was expected to reduce the absolute precision of localization by ~5mm (Acar and Makeig, 2013), this error was uniform across individuals and was still much smaller than the distance between PAC and brainstem.”
Loss of balance during balance beam walking elicits a multifocal theta band electrocortical response
Sipp, A. R., Gwin, J. T., Makeig, S., & Ferris, D. P. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00744.2012 · Cited by 232
Self-citationImaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
Self-citationMobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
Measuring speaker–listener neural coupling with functional near infrared spectroscopy
Liu, Y., Piazza, E. A., Simony, E., Shewokis, P. A., Onaral, B., Hasson, U., & Ayaz, H. (2017) · Scientific Reports · doi:10.1038/srep43293 · Cited by 180
Shenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
Burwell, S. J., Makeig, S., Iacono, W. G., & Malone, S. M. (2019) · Psychophysiology · doi:10.1111/psyp.13392 · Cited by 16
“The forward model estimation (which maps the amplitude of each dipole in source-space to the potential at each scalp-positioned channel) used recommended conductivity values for scalp (.33 Siemens [S]/meter [m]; Geddes & Baker, 1967), skull (25:1 brain-to-skull ratio, or .0132 S/m; Akalin Acar & Makeig, 2013; Lai et a…”
InfluentialSelf-citationMichelini, G., Lenartowicz, A., Diaz-Fong, J. P., Bilder, R. M., McGough, J. J., McCracken, J. T., & Loo, S. K. (2023) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1016/j.jaac.2022.06.017 · Cited by 12
du Bois, N., Korik, A., Hodge, S., Hudson, L., Elahi, A. S., Bigirimana, A., Dayan, N., Sanchez-Bornot, J. M., McCann, A., Yelden, K., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01574-x · Cited by 2
Metadata
- Authors
- Akalin Acar, Z., & Makeig, S.
- Venue
- Brain Topography
- Published
- 2013-01-26
- Volume
- 26
- Issue
- 3
- Pages
- 378-396
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- OpenAlex
- W2148582387
- Cited by
- 265
- References
- 60
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.