CoChat

Subcortical sources dominate the neuroelectric auditory frequency-following response to speech

Bidelman, Gavin M. · 2018 · NeuroImage
Cited by 241

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

&NA; Frequency‐following responses (FFRs) are neurophonic potentials that provide a window into the encoding of complex sounds (e.g., speech/music), auditory disorders, and neuroplasticity. While the neural origins of the FFR remain debated, renewed controversy has reemerged after demonstration that FFRs recorded via magnetoencephalography (MEG) are dominated by cortical rather than brainstem structures as previously assumed. Here, we recorded high‐density (64 ch) FFRs via EEG and applied state‐of‐the art source imaging techniques to multichannel data (discrete dipole modeling, distributed imaging, independent component analysis, computational simulations). Our data confirm a mixture of generators localized to bilateral auditory nerve (AN), brainstem inferior colliculus (BS), and bilateral primary auditory cortex (PAC). However, frequency‐specific scrutiny of source waveforms showed the relative contribution of these nuclei to the aggregate FFR varied across stimulus frequencies. Whereas AN and BS sources produced robust FFRs up to ˜700 Hz, PAC showed weak phase‐locking with little FFR energy above the speech fundamental (100 Hz). Notably, CLARA imaging further showed PAC activation was eradicated for FFRs >150 Hz, above which only subcortical sources remained active. Our results show (i) the site of FFR generation varies critically with stimulus frequency; and (ii) opposite the pattern observed in MEG, subcortical structures make the largest contribution to electrically recorded FFRs (AN ≥ BS > PAC). We infer that cortical dominance observed in previous neuromagnetic data is likely due to the bias of MEG to superficial brain tissue, underestimating subcortical structures that drive most of the speech‐FFR. Cleanly separating subcortical from cortical FFRs can be achieved by ensuring stimulus frequencies are >150–200 Hz, above the phase‐locking limit of cortical neurons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2018.03.060

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 241

Metadata

Authors
Bidelman, G. M.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2018-07
Volume
175
Pages
56-69
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2795174957
Cited by
241
References
7
FWCI
15.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subcortical sources dominate the neuroelectric auditory frequency-following response to speech. https://app.cochat.ai/papers/10.1016/j.neuroimage.2018.03.060
The paper
Bidelman, G. M. (2018). Subcortical sources dominate the neuroelectric auditory frequency-following response to speech. NeuroImage. https://doi.org/10.1016/j.neuroimage.2018.03.060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.