Effects of Forward Model Errors on EEG Source Localization
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Subject-specific four-layer boundary element method (BEM) electrical forward head models for four participants, generated from magnetic resonance (MR) head images using NFT (www.sccn.ucsd.edu/wiki/NFT), were used to simulate electroencephalographic (EEG) scalp potentials at 256 recorded electrode positions produced by single current dipoles of a 3-D grid in brain space. Locations of these dipoles were then estimated using gradient descent within five template head models fit to the electrode positions. These were: a spherical model, three-layer and four-layer BEM head models based on the Montreal Neurological Institute (MNI) template head image, and these BEM models warped to the recorded electrode positions. Smallest localization errors (4.1–6.2 mm, medians) were obtained using the electrode-position warped four-layer BEM models, with largest localization errors (~20 mm) for most basal brain locations. When we increased the brain-to-skull conductivity ratio assumed in the template model scalp projections from the simulated value (25:1) to a higher value (80:1) used in earlier studies, the estimated dipole locations moved outwards (12.4 mm, median). We also investigated the effects of errors in co-registering the electrode positions, of reducing electrode counts, and of adding a fifth, isotropic white matter layer to one individual head model. Results show that when individual subject MR head images are not available to construct subject-specific head models, accurate EEG source localization should employ a four- or five-layer BEM template head model incorporating an accurate skull conductivity estimate and warped to 64 or more accurately 3-D measured and co-registered electrode positions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Mining event-related brain dynamics
Makeig, S., Debener, S., Onton, J., & Delorme, A. (2004) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2004.03.008 · Cited by 1,493
Self-citationIndependent EEG Sources Are Dipolar
Delorme, A., Palmer, J., Onton, J., Oostenveld, R., & Makeig, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030135 · Cited by 810
Self-citationStatistical inverse problems: Discretization, model reduction and inverse crimes
Kaipio, J., & Somersalo, E. (2007) · Journal of Computational and Applied Mathematics · doi:10.1016/j.cam.2005.09.027 · Cited by 540
Current Distribution in the Brain From Surface Electrodes
RUSH, S., & DRISCOLL, D. A. (1968) · Anesthesia & Analgesia · doi:10.1213/00000539-196811000-00016 · Cited by 521
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494 · cited 1×
“This value has been shown to be reliable across subjects (Baumann et al. 1997).”
BackgroundThe conductivity of the human skull: results of in vivo and in vitro measurements
Oostendorp, T. F., Delbeke, J., & Stegeman, D. F. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2000.880100 · Cited by 467
Wolters, C. H., Anwander, A., Tricoche, X., Weinstein, D., Koch, M. A., & MacLeod, R. S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.014 · Cited by 452
A Bayesian approach to introducing anatomo-functional priors in the EEG/MEG inverse problem
Baillet, S., & Garnero, L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568913 · Cited by 322
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
MEG versus EEG localization test using implanted sources in the human brain
Cohen, D., Cuffin, B. N., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J., Kennedy, J. G., & Schomer, D. L. (1990) · Annals of Neurology · doi:10.1002/ana.410280613 · Cited by 294
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
The Influence of Brain Tissue Anisotropy on Human EEG and MEG
Haueisen, J., Tuch, D. S., Ramon, C., Schimpf, P. H., Wedeen, V. J., George, J. S., & Belliveau, J. W. (2002) · NeuroImage · doi:10.1006/nimg.2001.0962 · Cited by 228
Mathematical dipoles are adequate to describe realistic generators of human brain activity
de Munck, J. C., van Dijk, B. W., & Spekreijse, H. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8677 · Cited by 225
Lai, Y., van Drongelen, W., Ding, L., Hecox, K. E., Towle, V. L., Frim, D. M., & He, B. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.08.017 · Cited by 215
Güllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 214
Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery
Hoekema, R., Wieneke, G. H., Leijten, F. S. S., van Veelen, C. W. M., van Rijen, P. C., Huiskamp, G. J. M., Ansems, J., & van Huffelen, A. C. (2003) · Brain Topography · doi:10.1023/a:1025606415858 · Cited by 179
Influence of head models on EEG simulations and inverse source localizations
Ramon, C., Schimpf, P. H., & Haueisen, J. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-10 · Cited by 179
Marin, G., Guerin, C., Baillet, S., Garnero, L., & Meunier, G. (1998) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1998)6:4<250::aid-hbm5>3.0.co;2-2 · Cited by 168
How well does a three-sphere model predict positions of dipoles in a realistically shaped head?
Roth, B. J., Balish, M., Gorbach, A. M., & Sato, S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90017-p · Cited by 152
Regional head tissue conductivity estimation for improved EEG analysis
Tucker, D. M., Eriksen, K. J., & Ferrée, T. C. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.887939 · Cited by 152
The localization of equivalent dipoles of EEG sources by the application of electrical field theory
Henderson, C. J., Butler, S. R., & Glass, A. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90002-4 · Cited by 150
EEG localization accuracy improvements using realistically shaped head models
Cuffin, B. N. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.486287 · Cited by 137
Neuroelectromagnetic Forward Head Modeling Toolbox
Acar, Z. A., & Makeig, S. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.031 · Cited by 134
Self-citationSensitivity of EEG and MEG measurements to tissue conductivity
Gençer, N. G., & Acar, C. E. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/5/004 · Cited by 128
Geodesic photogrammetry for localizing sensor positions in dense-array EEG
Russell, G. S., Eriksen, K. J., Poolman, P., Luu, P., & Tucker, D. M. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.12.022 · Cited by 117
A systematic evaluation of the spherical model accuracy in EEG dipole localization
Yvert, B., Bertrand, O., Thévenet, M., Echallier, J. F., & Pernier, J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0921-884x(97)96611-x · Cited by 116
Influences of skull segmentation inaccuracies on EEG source analysis
Lanfer, B., Scherg, M., Dannhauer, M., Knösche, T. R., Burger, M., & Wolters, C. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.006 · Cited by 112
A novel integrated MEG and EEG analysis method for dipolar sources
Huang, M., Song, T., Hagler, D. J., Podgorny, I. A., Jousmäki, V., Cui, L., Gaa, K., Harrington, D. L., Dale, A. M., Lee, R. R., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.06.002 · Cited by 112
Lucka, F. F., Pursiainen, S., Burger, M., & Wolters, C. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.017 · Cited by 111
Modeling Skull Electrical Properties
Sadleir, R., & Argibay, A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9343-5 · Cited by 105
The electrical fields at the surface of the head during sleep
Brazier, M. A. B. (1949) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(49)90176-5 · Cited by 102
Estimating Brain Conductivities and Dipole Source Signals With EEG Arrays
Gutiérrez, D., Nehorai, A., & Muravchik, C. H. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836507 · Cited by 95
Dipole location errors in electroencephalogram source analysis due to volume conductor model errors
Vanrumste, B., Hoey, G. V., Rik Van De Walle, B., D’Havé, M., Lemahieu, I. A., & Boon, P. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345748 · Cited by 91
Generic head models for atlas‐based EEG source analysis
Darvas, F., Ermer, J. J., Mosher, J. C., & Leahy, R. M. (2005) · Human Brain Mapping · doi:10.1002/hbm.20171 · Cited by 84
Approximate average head models for EEG source imaging
Valdes-Hernandez, P. A., von Ellenrieder, N., Ojeda, A., Kochen, S. S., Alemán‐Gómez, Y., Muravchik, C. H., & Valdes-Sosa, P. A. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.09.005 · Cited by 83
The Influence of CSF on EEG Sensitivity Distributions of Multilayered Head Models
Wendel, K., Narra, N., Hannula, M., Kauppinen, P., & Malmivuo, J. A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912427 · Cited by 82
Wang, Y., & Gotman, J. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00594-6 · Cited by 81
Electrical conductivity imaging via contactless measurements: an experimental study
Karbeyaz, B. Ü., & Gençer, N. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812271 · Cited by 79
Hallez, H., Vanrumste, B., Hese, P. V., Delputte, S., & Lemahieu, I. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/7/005 · Cited by 73
Chauveau, N., Franceries, X., Doyon, B., Rigaud, B., Morucci, J. P., & Celsis, P. (2003) · Human Brain Mapping · doi:10.1002/hbm.10152 · Cited by 72
An evaluation of dipole reconstruction accuracy with spherical and realistic head models in MEG
Cheylus, A., Yvert, B., Bertrand, O., & Pernier, J. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00174-1 · Cited by 70
Akalin-Acar, Z., & Gençer, N. G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/21/012 · Cited by 69
Self-citationSpatial mislocalization of EEG electrodes – effects on accuracy of dipole estimation
Khosla, D., Don, M., & Kwong, B. (1999) · Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00121-7 · Cited by 66
Lew, S., Wolters, C. H., Anwander, A., Makeig, S., & MacLeod, R. (2008) · Human Brain Mapping · doi:10.1002/hbm.20714 · Cited by 63
Self-citationA Study of the Electrical Fields at the Surface of the Head
Brazier, M. A. B. (1966) · American Journal of EEG Technology · doi:10.1080/00029238.1966.11080676 · Cited by 57
Gao, N., Zhu, S. A., & He, B. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/016 · Cited by 53
Neural Correlates of Visual?Spatial Attention in Electrocorticographic Signals in Humans
Gunduz, A., Brunner, P., Daitch, A., Leuthardt, E. C., Ritaccio, A. L., Pesaran, B., & Schalk, G. (2011) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00089 · Cited by 51
Effect of Inhomogeneities on Surface Signals Coming from a Cerebral Current-Dipole Source
Schneider, M. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324363 · Cited by 47
Uitert, R. V., Johnson, C. R., & Евгеньевич, Ж. Л. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836490 · Cited by 47
Shaw, J. C., & Roth, M. (1955) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(55)90041-9 · Cited by 44
L�tkenh�ner, B., Menninghaus, E., Steinstr�ter, O., Wienbruch, C., Gi�ler, H. M., & Elbert, T. R. (1995) · Brain Topography · doi:10.1007/bf01195255 · Cited by 40
Parallel implementation of the accelerated BEM approach for EMSI of the human brain
Ataseven, Y., Akalin-Acar, Z., Acar, C. E., & Gençer, N. G. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0316-0 · Cited by 37
Self-citationKobayashi, K., Yoshinaga, H., Oka, M., Ohtsuka, Y., & Gotman, J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00064-6 · Cited by 26
Patch-basis electrocortical source imaging in epilepsy
Acar, Z. A., Worrell, G. A., & Makeig, S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333992 · Cited by 13
Self-citation
Cited by
EEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
Self-citationMobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
Metadata
- Authors
- Akalin Acar, Z., & Makeig, S.
- Venue
- Brain Topography
- Published
- 2013-01-26
- Volume
- 26
- Issue
- 3
- Pages
- 378-396
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- OpenAlex
- W2148582387
- Cited by
- 265
- References
- 60
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.