Cited by 13Retinal Development and DisordersRetinal Diseases and TreatmentsDrug-Induced Ocular Toxicity

Electrophysiological and microperimetry changes in vitamin A deficiency retinopathy

Saker, Saker, Morales, Marco, Jhittay, Harsimar, Wen, Yaqin, Amoaku, Winfried·2015·Documenta Ophthalmologica

Abstract

Purpose To describe a follow-up case of vitamin A deficiency (VAD)-related retinopathy with macular involvement monitored with electroretinography and microperimetry. Methods Flash (ERG), pattern (PERG), and multifocal (mfERG) electroretinography were recorded in parallel with microperimetry before and during 7-month follow-up of vitamin A treatment on a 65-year-old man presented with a 1-year history of night blindness. The patient had undergone ileostomy procedure for Crohn's disease 14 years ago. His best corrected visual acuity was 6/6 in each eye. Fundus examination revealed macular and mid-peripheral yellow-white lesions compatible with drusen. Results Before treatment, PERG was reduced, and mfERG was reduced and delayed, worse in responses from the central rings. These results revealed evidence of bilateral macular and central cone dysfunction. The flash ERG showed reduced dark-adapted 0.01 ERG (rod response); a-wave of dark-adapted 3.0 and 10.0 ERG was normal but b-wave was reduced (negative configuration); light-adapted 3.0 ERG was slightly reduced. The flash ERG revealed evidence of bilateral generalised retinal dysfunction affecting the rod more than cone system. Microperimetry showed deep reduction in retinal sensitivity. Fixation stability was unstable with eccentric locus. During treatment, ERG and microperimetry demonstrated significant improvements. Fixation stability reached normal values after the third treatment week. Conclusions This case illustrates the importance of electrophysiological investigation in early VAD-related retinopathy detection correlated with microperimetry. Our findings indicate a more delayed central cone function recovery than that of generalised rod and cone function. There was a marked correlation between ERG and microperimetric changes.

Integrity signals

Registry

Crossref · 10.1007/s10633-015-9484-z

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Vitamin A is needed for normal visual function, and vitamin A deficiency (hypovitaminosis A) results in visual dysfunction that is reversible with vitamin A supplementation.

    “Vitamin A is needed for normal visual function and vitamin A deficiency (hypovitaminosis A) results in visual dysfunction that is reversible with vitamin A supplementation.”

    From The Role of Vitamin A in Retinal Diseases (2022) · cites this paper as [80]

  • Vitamin A replacement results in improvement of retinal function as well as structure, but long-term deficiency can lead to permanent degeneration of photoreceptors.

    “Vitamin A replacement results in improvement of retinal function as well as structure, however long-term deficiency can lead to permanent degeneration of photoreceptors [31,80,81,83,84,85,86,87,88,90].”

    From The Role of Vitamin A in Retinal Diseases (2022) · cites this paper as [80]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Saker, S., Morales, M., Jhittay, H., Wen, Y., & Amoaku, W.
Affiliations
  • University of Nottingham (GB)
  • Nottingham University Hospitals NHS Trust (GB)
Corresponding author
Amoaku, Winfried
Venue
Documenta Ophthalmologica
Published
2015-01-28
Volume
130
Issue
3
Pages
231-240
ISSN
  • 0012-4486 (ISSN-L)
  • 1573-2622
OpenAlex
W2094157359
Cited by
13
References
39
Citations by year
2025: 1 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 1 · 2019: 2 · 2017: 1 · 2016: 1 · 2015: 1
FWCI
0.43
Type
journal article
Language
en
Open access
closed
Locations
  • Documenta Ophthalmologica (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Health Sciences › Medicine › Ophthalmology › Drug-Induced Ocular Toxicity
Keywords
night blindness, electroretinogram, microperimetry, multifocal electroretinogram, pattern electroretinography, rod function, retinal sensitivity, vitamin A supplementation, Crohn's disease, ileostomy, drusen
MeSH terms
Administration, Oral, Aged, Crohn Disease, Dark Adaptation, Electroretinography, Humans, Ileostomy, Injections, Intramuscular, Male, Night Blindness, Photic Stimulation, Retina, Retinal Diseases, Visual Acuity, Visual Fields, Vitamin A, Vitamin A Deficiency, Vitamins, Photoreceptor Cells, Vertebrate, Visual Field Tests

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review