A prospective study of anxiety in ICD patients with a pilot randomized controlled trial of cognitive behavioral therapy for patients with moderate to severe anxiety.
The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.
Abstract
Purpose: Stress and anxiety are potential consequences from arrhythmias and implantable cardioverter defibrillator (ICD) shocks that can contribute to substantial morbidity. We assessed anxiety associated with an ICD and whether cognitive behavioral therapy (CBT) reduces anxiety.Methods: The study consisted of two parts: part 1 (N = 690) was a prospective cross-sectional observational study of consecutive ICD patients. Patients completed the Beck Anxiety Inventory (BAI), Generalized Anxiety Disorder Scale (GAD-7), Florida Shock Anxiety Scale (FSAS), and Florida Patient Acceptance Survey (FPAS) psychometric tests. Part 2 (N = 29) was a pilot randomized controlled trial of CBT (three sessions in 3 months) vs. usual care (UC) in patients with BAI ≥ 19 from part 1.Results: The median BAI and GAD-7 scores were 5 and 2, respectively. By BAI scores, 64.5 % had minimal and 3.9 % had severe anxiety. By GAD-7 scores, 73.0 % had low probability of anxiety and 2.9 % had high anxiety. Higher anxiety levels were associated with recent (p = 0.017) and total number of shocks (p = 0.002). Any shock was associated with fear about shocks (FSAS, p < 0.001) and reduced patient ICD acceptance (FPAS, p = 0.019). In the pilot trial of CBT, median BAI scores decreased from 24.5 to 11 at 1 year (p = 0.031) in the CBT group and GAD-7 scores from 12.5 to 7 (p = 0.063); no significant changes in anxiety scores were observed in the UC group.Conclusions: Severe anxiety was present in a small proportion of ICD patients, but higher anxiety was associated with recent and total number of shocks. The small pilot study suggested that a simple program of CBT might lower moderate-high anxiety with lasting effects to 1 year and supports the need for a larger trial to validate these results.Clinical Trial Registration: ClinicalTrials.gov identifier: NCT00851071. URL: http://clinicaltrials.gov/ct2/show/NCT00851071?term=anxiety+in+icd+patients+cleveland+clinic&rank=1.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
An inventory for measuring clinical anxiety: Psychometric properties.
Beck, A. T., Epstein, N., Brown, G., & Steer, R. A. (1988) · Journal of Consulting and Clinical Psychology · doi:10.1037/0022-006x.56.6.893 · Cited by 14,407
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · cited 1×
“The implantable cardioverter defibrillator (ICD) provides lifesaving treatment for ventricular arrhythmias with indications having expanded for both primary and secondary prevention of sudden cardiac death [1–5].”
BackgroundJulian, L. J. (2011) · Arthritis Care & Research · doi:10.1002/acr.20561 · Cited by 1,794
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,126
Emotional and physical precipitants of ventricular arrhythmia
Lampert, R., Joska, T., Burg, M. M., Batsford, W. P., McPherson, C. A., & Jain, D. (2002) · Circulation · doi:10.1161/01.cir.0000031733.51374.c1 · Cited by 347 · cited 1×
“Anxiety disorders are reported in up to 38 % of ICD patients [6–9] and have been associated with both appropriate and inappropriate shocks [10, 11], as well as worse quality of life [12].”
BackgroundExamining the psychosocial impact of implantable cardioverter defibrillators: A literature review
Camm, A. J., Sears, S. F., Todaro, J. F., Lewis, T. S., Sotile, W., & Conti, J. B. (1999) · Clinical Cardiology · doi:10.1002/clc.4960220709 · Cited by 292
Self-citationValidity of the Generalized Anxiety Disorder‐7 Scale in an Acute Psychiatric Sample
Kertz, S., Bigda‐Peyton, J., & Bjorgvinsson, T. (2013) · Clinical Psychology & Psychotherapy · doi:10.1002/cpp.1802 · Cited by 271 · cited 1×
“The total scores indicate low probability of anxiety (0–4), mild anxiety (5–9), moderate anxiety (10–14), and severe anxiety (15–21) [22].”
Background
Cited by
Perini, A. P., Kutyifa, V., Veazie, P. J., Daubert, J. P., Schuger, C. D., Zaręba, W., McNitt, S. A., Rosero, S. Z., TOMPKINS, C. M., Padeletti, L., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.03.009 · Cited by 90
“In addition, a recent pilot study confirmed that in the specific subset of ICD patients with moderate-high anxiety, a 3-month program of cognitive behavioral therapy has beneficial effects.(14) As for QoL, we did not find any reduction in EQ-5D, with the sole exception of the appreciation of more anxiety/depression af…”
Inflammatory response to mental stress and mental stress induced myocardial ischemia
Hammadah, M., Sullivan, S. M., Pearce, B. D., Mheid, I. A., Wilmot, K. A., Ramadan, R., Tahhan, A. S., O’Neal, W. T., Obideen, M., Alkhoder, A. A., et al. (2017) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2017.10.004 · Cited by 67
“…endothelial dysfunction; (Ghiadoni et al., 2000; Xue, 2015) atherosclerosis; (Harrison et al., 2003; Das and O’Keefe, 2006) cardiac arrhythmia; (Qintar et al., 2015) acute coronary syndromes; (Vaccarino, 2016; Burg and Soufer, 2014) and cardiovascular events (Das and O’Keefe, 2006; Rosengren…”
Protogerou, C., Fleeman, N., Dwan, K. M., Richardson, M., Dundar, Y., & Hagger, M. S. (2015) · Behaviour Research and Therapy · doi:10.1016/j.brat.2015.08.004 · Cited by 48
Tripp, C., Huber, N. L., Kuhl, E. A., & Sears, S. F. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13793 · Cited by 38
Self-citationKim, A. M., Jeon, S. W., Cho, S. J., Shin, Y. C., & Park, J. (2021) · Asian Journal of Psychiatry · doi:10.1016/j.ajp.2021.102844 · Cited by 38
Habibović, M., Denollet, J., Cuijpers, P., van der Voort, P. H., Herrman, J.-P., Bouwels, L., Valk, S. D. A., Alings, M., Theuns, D. A. M. J., & Pedersen, S. S. (2017) · Health Psychology · doi:10.1037/hea0000451 · Cited by 26
Self-citationVersteeg, H., Timmermans, I., Meine, M., Zitron, E., Mabo, P., & Denollet, J. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.03.124 · Cited by 27
Risom, S. S., Lind, J., McCabe, P. J., & Berg, S. K. (2018) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s152823 · Cited by 25
“23 In this study and others, 22,23,31 the support of clinicians was important for coping with the fear and anxiety of recurrent arrhythmias.”
Neuropsychiatric disorders in patients with heart failure: not to be ignored
Manolis, T. A., Manolis, A. S., Melita, H., & Manolis, A. S. (2022) · Heart Failure Reviews · doi:10.1007/s10741-022-10290-2 · Cited by 24
“Anxiety in patients with devices In patients with an ICD, severe anxiety may be present in a small proportion of these patients, but higher anxiety is generally associated with recent and total number of ICD shocks [57].”
BackgroundGürel, T. Y., & Mert, H. (2017) · Clinical Nursing Research · doi:10.1177/1054773817741427 · Cited by 20
“(2015) reported an improvement in the anxiety levels of patients in the third month (Qintar et al., 2015).”
BackgroundBerg, S. K., Herning, M., Svendsen, J. H., Christensen, A. V., & Thygesen, L. C. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-013186 · Cited by 18
“Significant differences were found after three CBT sessions.(26) All interventional trials were small and the intervention was very short.”
BackgroundSpaderna, H., Brandenburg, V. M., Lauterbach, M., Partetzke, T. M., Schwab, S. U., Voss, F., & Kindermann, I. (2024) · PLoS ONE · doi:10.1371/journal.pone.0309952 · Cited by 15
“Moreover, any shock experience was only related to shock-specific fear, whereas general anxiety levels were associated with recent and total number of shocks [44].”
BackgroundSandhu, U. G., Kovacs, A. H., & Nazer, B. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.09.011 · Cited by 13
“Furthermore, cognitivebehavioral therapy sessions in ICD patients, when compared to usual care, resulted in reduction in anxiety as evaluated by a small RCT.(45) Patients who suffer repeated ICD shocks from VT storm can often meet formal criteria for PTSD.”
MethodSanders, K., Chousou, P., Carver, K., Pugh, P., Degens, H., & Azzawi, M. (2022) · Open Heart · doi:10.1136/openhrt-2022-002021 · Cited by 7
Coppler, P. J., Brown, M., Moschenross, D. M., Gopalan, P. R., Presciutti, A., Doshi, A. A., Sawyer, K. N., Frisch, A., Callaway, C. W., & Elmer, J. (2023) · Journal of Intensive Care Medicine · doi:10.1177/08850666231218963 · Cited by 8
“39 These interventions can be adapted for CA survivors given the considerable overlap between both populations.”
BackgroundStereotactic radioablation for ventricular tachycardia
Hohmann, S., Hillmann, H. A. K., Müller‐Leisse, J., et al. (2021) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-021-00830-y · Cited by 8
“Therapy with an implantable cardioverter-defibrillator (ICD) prevents sudden cardiac death in patients at high risk of ventricular arrhythmias, but recurrent ICD shocks increase overall mortality and have a considerable impact on quality of life [6, 33].”
BackgroundNicmanis, M., Arcangeli, O., Chur‐Hansen, A., & Oxlad, M. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.02.027 · Cited by 9
Presciutti, A. M., Bannon, S. M., Yamin, J. B., Newman, M. M., Parker, R. A., Elmer, J., Wu, O., Donnino, M. W., Perman, S. M., & Vranceanu, A.-M. (2023) · Journal of Behavioral Medicine · doi:10.1007/s10865-023-00405-x · Cited by 5
“Notably, however, previous interventions in ICD recipi - ents that focused on mindfulness-based exercises were efficacious in reducing anxiety and distress (Irvine et al., 2011; Qintar et al., 2015).”
Pasyar, N., Rambod, M., Zare, A., & Nikoo, M. H. (2022) · Malaysian Journal of Medical Sciences · doi:10.21315/mjms2022.29.3.8 · Cited by 5
Richards, K., Freeman, L. K., & Sears, S. F. (2016) · Journal of Consumer Health on the Internet · doi:10.1080/15398285.2016.1201787 · Cited by 7
“Device acceptance has demonstrated utility in identifying ICD patients who have been shocked (Qintar et al. 2015) and those who have been involved in device recalls (Keren et al. 2011).”
BackgroundResultInfluentialSelf-citationBozat, A. D., Akgül, S., Ertuğrul, İ., & Karagöz, T. (2020) · Cardiology in the Young · doi:10.1017/s1047951120003388 · Cited by 7
Cardiac sympathetic denervation and mental health
Khalsa, S. S., Clausen, A. N., Shahabi, L., Sorg, J. M., Gonzalez, S. E., Naliboff, B. D., Shivkumar, K., & Ajijola, O. A. (2021) · Autonomic Neuroscience · doi:10.1016/j.autneu.2021.102787 · Cited by 4
Impact of Sudden Cardiac Arrest and Implantable Cardiac Defibrillator Shocks on Mental Health
Torbey, E., Mena‐Hurtado, C., Jackson, J. L., Samaan, Z., Sears, S. F., Pedersen, S. S., Lala, A., Thachil, R., Steiner, J. M., Ilonze, O. J., et al. (2025) · JACC Advances · doi:10.1016/j.jacadv.2025.101797 · Cited by 8
Self-citationDenollet, J., Pedersen, S. S., Warnaars, F. E., & Habibović, M. (2020) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2020.110106 · Cited by 3
Self-citationPsychosocial Concerns in Patients Living with an Implantable Cardioverter Defibrillator
Thylén, I. (2017) · Springer eBooks · doi:10.1007/978-3-319-55721-2_3 · Cited by 5
Psychiatric Aspects of Sudden Cardiac Arrest and Implantable Cardioverter-Defibrillators
Savastano, S., Baldi, E., & Brondino, N. (2020) · Springer eBooks · doi:10.1007/978-3-319-90305-7_21-1 · Cited by 2
Psychiatric Aspects of Sudden Cardiac Arrest and Implantable Cardioverter-Defibrillators
Savastano, S., Baldi, E., & Brondino, N. (2020) · Springer eBooks · doi:10.1007/978-3-030-28008-6_21 · Cited by 2
Akay, B., & Oğuz, S. (2023) · Clinical and Experimental Health Sciences · doi:10.33808/clinexphealthsci.1203235
The utility of the Florida Shock Anxiety Scale: What have we learned?
Jalloul, Y., & Refaat, M. M. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13794
Huntelaar, M. J., van der Lingen, A. C. J., Rijnierse, M. T., Elshout, S., van Halm, V. P., Leeuwis, A. E., Hopman, L. H. G. A., & Allaart, C. P. (2026) · Heart Rhythm O2 · doi:10.1016/j.hroo.2026.04.004
“27 37”
Metadata
- Authors
- Qintar, M., George, J. J., Panko, M., Bea, S., Broer, K. A., St. John, J., Blissett, K.-A., Ching, E., Sears, S. F., Pedersen, S. S., Pozuelo, L., & Chung, M. K.
- Affiliations
- Cleveland Clinic (US)
- East Carolina University (US)
- University of Southern Denmark (DK)
- Corresponding author
- Chung, Mina K.
- Venue
- Journal of Interventional Cardiac Electrophysiology
- Published
- 2015-03-17
- Volume
- 43
- Issue
- 1
- Pages
- 65-75
- ISSN
- 1383-875X (ISSN-L)
- 1572-8595
- OpenAlex
- W1972724460
- Cited by
- 30
- References
- 36
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 1 · 2017: 6 · 2016: 2 · 2015: 1
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Interventional Cardiac Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL111314, R01HL090620)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Anxiety, Depression, Psychometrics, Treatment, Cognitive Processes
- Keywords
- implantable cardioverter-defibrillator, anxiety, cognitive behavioral therapy, ICD shocks, cardiac arrhythmias, psychological stress, generalized anxiety disorder, Beck Anxiety Inventory, GAD-7, anxiety reduction intervention
- MeSH terms
- Female, Heart Failure, Humans, Male, Middle Aged, Pilot Projects, Prospective Studies, Stress, Psychological, Cognitive Behavioral Therapy, Treatment Outcome, Defibrillators, Implantable
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.