Calculation of peripheral capillary oxygen saturation $${\text{(SpO}}_{{\text{2}}} {\text{)}}$$ (SpO 2 ) levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. These techniques are: (1) “Red over Infrared,” calculating the ratios of AC and DC components of the red and infrared PPG signals, $$\frac{(AC/DC)_{red}}{(AC/DC)_{infrared}}$$ ( A C / D C ) red ( A C / D C ) infrared , followed by the use of a calibration curve to determine the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level Webster (in: Design of pulse oximeters, CRC Press, Boca Raton, 1997); and (2) a motion-resistant algorithm which uses the Discrete Saturation Transform (DST) (Goldman in J Clin Monit Comput 16:475–83, 2000). The DST algorithm isolates individual “saturation components” in the optical pathway, which allows separation of components corresponding to the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level from components corresponding to noise and interference, including motion artifacts. The comparison we provide here (employing the two techniques with and without pre-filtering) addresses two aspects: (1) accuracy of the $${\text{SpO}}_{{\text{2}}}$$ SpO 2 calculations; and (2) computational complexity. We used both synthetic data and experimental data collected from human subjects. The human subjects were tested at rest and while exercising; while exercising, their measurements were subject to the impacts of motion. Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the “Red over Infrared” approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between $${\text{SpO}}_{{\text{2}}}$$ SpO 2 -level accuracy and computational complexity. A modest improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in $${\text{SpO}}_{{\text{2}}}$$ SpO 2 level accuracy at −10 dB over unfiltered DST algorithm and the filtered “Red over Infrared” approach). However, this improvement comes at a significant computational cost.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10877-020-00539-2

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Performance of SpO2 measurement can be improved by filtering the PPG to accentuate the heart frequency.

    “Performance can be improved by filtering the PPG to accentuate the heart frequency”

    From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [137]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [10]Clarke GW. Signal quality analysis in pulse oximetry: modelling and detection of motion artifact (Doctoral dissertation). Carleton University; 2015.

Cited by

Sorted by citations

Authors
Alkhoury, L., Choi, J.-W., Wang, C., Rajasekar, A., Acharya, S., Mahoney, S., Shender, B. S., Hrebien, L., & Kam, M.
Affiliations
  • New Jersey Institute of Technology (US)
  • Drexel University (US)
  • Naval Air Warfare Center Aircraft Division (US)
Corresponding author
Alkhoury, Ludvik
Venue
Journal of Clinical Monitoring and Computing
Published
2020-06-17
Volume
35
Issue
4
Pages
797-813
ISSN
  • 1387-1307 (ISSN-L)
  • 1573-2614
OpenAlex
W3036237291
Cited by
15
References
27
Citations by year
2026: 6 · 2025: 2 · 2024: 1 · 2022: 4 · 2021: 2
FWCI
0.47
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Monitoring and Computing (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Office of Naval Research (N68335-16-C-0085)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
pulse oximetry, photoplethysmogram, oxygen saturation estimation, motion artifacts, computational complexity, low signal-to-noise ratio
MeSH terms
Algorithms, Heart Rate, Humans, Oximetry, Signal Processing, Computer-Assisted, Artifacts, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review