Cited by 62Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesECG Monitoring and Analysis

An Efficient Motion-Resistant Method for Wearable Pulse Oximeter

Yan, Yong-Sheng, Zhang, Yuan-Ting·2008·IEEE Transactions on Information Technology in Biomedicine

Abstract

Reduction of motion artifact and power saving are crucial in designing a wearable pulse oximeter for long-term telemedicine application. In this paper, a novel algorithm, minimum correlation discrete saturation transform (MCDST) has been developed for the estimation of arterial oxygen saturation (SaO2), based on an optical model derived from photon diffusion analysis. The simulation shows that the new algorithm MCDST is more robust under low SNRs than the clinically verified motion-resistant algorithm discrete saturation transform (DST). Further, the experiment with different severity of motions demonstrates that MCDST has a slightly better performance than DST algorithm. Moreover, MCDST is more computationally efficient than DST because the former uses linear algebra instead of the time-consuming adaptive filter used by latter, which indicates that MCDST can reduce the required power consumption and circuit complexity of the implementation. This is vital for wearable devices, where the physical size and long battery life are crucial.

Integrity signals

Registry

Crossref · 10.1109/titb.2007.902173

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Although systems of this type have shown promising results, additional work appears necessary to achieve motion artifact reduction.

    “Although systems of this type have shown promising results, additional work appears to be necessary to achieve motion artifact reduction [27,28].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yan, Y.-S., & Zhang, Y.-T.
Affiliations
Chinese University of Hong Kong (HK)
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2008-05
Volume
12
Issue
3
Pages
399-405
ISSN
  • 1089-7771 (ISSN-L)
  • 1558-0032
OpenAlex
W2158319938
Cited by
62
References
17
Citations by year
2026: 1 · 2024: 1 · 2023: 3 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 5 · 2016: 8 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 5
FWCI
3.32
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
motion artifact reduction, low signal-to-noise ratio, energy consumption reduction, telemedicine, computational efficiency
MeSH terms
Algorithms, Diagnosis, Computer-Assisted, Humans, Motion, Oximetry, Sensitivity and Specificity, Reproducibility of Results, Artifacts, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review