An Efficient Motion-Resistant Method for Wearable Pulse Oximeter
Abstract
Reduction of motion artifact and power saving are crucial in designing a wearable pulse oximeter for long-term telemedicine application. In this paper, a novel algorithm, minimum correlation discrete saturation transform (MCDST) has been developed for the estimation of arterial oxygen saturation (SaO2), based on an optical model derived from photon diffusion analysis. The simulation shows that the new algorithm MCDST is more robust under low SNRs than the clinically verified motion-resistant algorithm discrete saturation transform (DST). Further, the experiment with different severity of motions demonstrates that MCDST has a slightly better performance than DST algorithm. Moreover, MCDST is more computationally efficient than DST because the former uses linear algebra instead of the time-consuming adaptive filter used by latter, which indicates that MCDST can reduce the required power consumption and circuit complexity of the implementation. This is vital for wearable devices, where the physical size and long battery life are crucial.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Although systems of this type have shown promising results, additional work appears necessary to achieve motion artifact reduction.
“Although systems of this type have shown promising results, additional work appears to be necessary to achieve motion artifact reduction [27,28].”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [27]
Cites
(1997) · Institute of Physics eBooks · doi:10.1887/0750304677 · Cited by 455 · see citing works
(1997) · Series in medical physics and biomedical engineering · doi:10.1201/9781420050790 · Cited by 364 · see citing works
Masimo Signal Extraction Pulse Oximetry
Goldman, J. M., Petterson, M. T., Kopotic, R. J., & Barker, S. J. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011493521730 · Cited by 283 · see citing works
Artifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235 · see citing works
Signal processing methods for pulse oximetry
Rusch, T. L., Sankar, R. T., & Scharf, J. E. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00049-6 · Cited by 185 · see citing works
“Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models
Barker, S. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200210000-00033 · Cited by 176 · see citing works
Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
Yan, Y. S., Poon, C. C. Y., & Zhang, Y. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-3 · Cited by 157 · see citing works
Self-citationThe Pulse Oximeter: Applications and Limitations—An Analysis of 2000 Incident Reports
Runciman, W. B., Webb, R. K., Barker, L., et al. (1993) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9302100509 · Cited by 123 · see citing works
Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
Schmitt, J. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137285 · Cited by 118 · see citing works
Givens rotation based least squares lattice and related algorithms
Ling, F. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.134393 · Cited by 92 · see citing works
Clinical Evaluation of a Prototype Motion Artifact Resistant Pulse Oximeter in the Recovery Room
Dumas, C., Wahr, J. A., & Tremper, K. K. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199608000-00012 · Cited by 81 · see citing works
Artifact reduction in photoplethysmography
Hayes, M., & Smith, P. R. (1998) · Applied Optics · doi:10.1364/ao.37.007437 · Cited by 71 · see citing works
A characterization of motion affecting pulse oximetry in 350 patients.
Tobin, R. M., Pologe, J. A., & Batchelder, P. B. (2002) · PubMed · Cited by 38 · see citing works
Visram, A., Jones, R. D. M., Irwin, M. G., et al. (1994) · British Journal of Anaesthesia · doi:10.1093/bja/72.4.388 · Cited by 27 · see citing works
Determining the Artifact Sensitivity of Recent Pulse Oximeters during Laboratory Benchmarking
Kästle, S. W., & Konecny, E. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011420228523 · Cited by 19 · see citing works
Neural networks and wavelet analysis in the computer interpretation of pulse oximetry data
Dowla, F., Skokowski, P. G., & Leach, R. R. (2002) · doi:10.1109/nnsp.1996.548383 · Cited by 13 · see citing works
Mathematical model of transmission pulse oximetry
Marble, D. R., & Cheung, P. W. (1988) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1988.94651 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396 · see citing works
Wearable Medical Systems for p-Health
Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008248 · Cited by 310 · see citing works
Self-citationWearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281 · see citing works
Self-citationSignal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166 · see citing works
Multi-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107 · see citing works
Self-citationA Flexible, Low Noise Reflective PPG Sensor Platform for Ear-Worn Heart Rate Monitoring
Patterson, J. A. C., McIlwraith, D. C., & Yang, G.-Z. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.16 · Cited by 91 · see citing works
Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry
Alkhoury, L., Choi, J.-W., Wang, C., Rajasekar, A., Acharya, S., Mahoney, S., Shender, B. S., Hrebien, L., & Kam, M. (2021) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00539-2 · Cited by 15 · see citing works
- Authors
- Yan, Y.-S., & Zhang, Y.-T.
- Affiliations
- Chinese University of Hong Kong (HK)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2008-05
- Volume
- 12
- Issue
- 3
- Pages
- 399-405
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2158319938
- Cited by
- 62
- References
- 17
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 3 · 2022: 4 · 2021: 3 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 5 · 2016: 8 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 5
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- motion artifact reduction, low signal-to-noise ratio, energy consumption reduction, telemedicine, computational efficiency
- MeSH terms
- Algorithms, Diagnosis, Computer-Assisted, Humans, Motion, Oximetry, Sensitivity and Specificity, Reproducibility of Results, Artifacts, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review