Colloidal stability of polymeric nanoparticles in biological fluids
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Estimating the colloidal stability of polymeric nanoparticles (NPs) in biological environments is critical for designing optimal preparations and to clarify the fate of these devices after administration. To characterize and quantify the physical stability of nanodevices suitable for biomedical applications, spherical NPs composed of poly-lactic acid (PLA) and poly-methyl-methacrylate (PMMA), in the range 100–200 nm, were prepared. Their stability in salt solutions, biological fluids, serum and tissue homogenates was analyzed by dynamic light scattering (DLS). The PMMA NPs remained stable in all fluids, while PLA NPs aggregated in gastric juice and spleen homogenate. The proposed stability test is therefore useful to see in advance whether NPs might aggregate when administered in vivo. To assess colloidal stability ex vivo as well, spectrophotofluorimetric analysis was employed, giving comparable results to DLS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymeric nanoparticles based drug delivery systems
Kumari, A., Yadav, S. K., & Yadav, S. C. (2010) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2009.09.001 · Cited by 3,724 · cited 1×
“Their use permits a comparison of a hydrolytically degradable material, PLA, and a non-degradable one, PMMA (Devalapally et al. 2007; Kumari et al. 2010; Cui et al. 2009; Prokop and Davidson 2008).”
BackgroundFactors affecting the clearance and biodistribution of polymeric nanoparticles
Alexis, F., Pridgen, E., Molnar, L. K., & Farokhzad, O. C. (2008) · Molecular Pharmaceutics · doi:10.1021/mp800051m · Cited by 3,699 · cited 1×
“To overcome these hurdles, the use of biocompatible drug-loaded nanoparticles (NPs) has been proposed (Alexis et al. 2008).”
BackgroundHe, C., Hu, Y., Yin, L., Tang, C., & Yin, C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.065 · Cited by 2,607 · cited 1×
“For PLA, cholesteryl Bodipy was chosen for its high hydrophobicity, an important issue when dealing with nanoprecipitation (Fessi et al. 1989; Mora-Huertas et al. 2010).”
MethodNanocapsule formation by interfacial polymer deposition following solvent displacement
Fessi, H., Puisieux, F., Devissaguet, J. P., Ammoury, N., & Benita, S. (1989) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(89)90281-0 · Cited by 2,288 · cited 1×
“For PLA, cholesteryl Bodipy was chosen for its high hydrophobicity, an important issue when dealing with nanoprecipitation (Fessi et al. 1989; Mora-Huertas et al. 2010).”
MethodAggarwal, P., Hall, J. B., McLeland, C. B., Dobrovolskaia, M. A., & McNeil, S. E. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.009 · Cited by 1,791 · cited 1×
“While the interaction of NPs with serum proteins has been investigated (Aggarwal et al. 2009), with particular attention to opsonization, and many theories have been proposed concerning the release mechanisms (Arifin et al. 2006), the stability of NPs in biological fluids has not been fully…”
BackgroundPolymer-based nanocapsules for drug delivery
Mora-Huertas, C. E., Fessi, H., & Elaissari, A. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.10.018 · Cited by 1,742
Yin Win, K., & Feng, S.-S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.050 · Cited by 1,452 · cited 3×
“…1996; Avgoustakis et al. 2002), and different degradation mechanisms have been identified depending on NPs dimensions and polymer reactivity (von Burkersroda et al. 2002), the colloidal stability still remains poorly investigated (Win and Feng 2005; Ruenraroengsak et al. 2010; Madlova et al. 2009).”
BackgroundNanomedicine—Challenge and Perspectives
Riehemann, K., Schneider, S. W., Luger, T. A., Godin, B., Ferrari, M., & Fuchs, H. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200802585 · Cited by 1,305 · cited 1×
“Polymeric NPs are an innovative generation of nanovectors with great potential as drug carriers and tracking devices for targeted delivery to specific sites (Riehemann et al. 2009).”
BackgroundWhy degradable polymers undergo surface erosion or bulk erosion
Burkersroda, F. V., Schedl, L., & Göpferich, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00170-9 · Cited by 1,146 · cited 1×
“…et al. 1996; Avgoustakis et al. 2002), and different degradation mechanisms have been identified depending on NPs dimensions and polymer reactivity (von Burkersroda et al. 2002), the colloidal stability still remains poorly investigated (Win and Feng 2005; Ruenraroengsak et al. 2010; Madlova…”
BackgroundPhysical models of diffusion for polymer solutions, gels and solids
Masaro, L., & Zhu, X. X. (1999) · Progress in Polymer Science · doi:10.1016/s0079-6700(99)00016-7 · Cited by 913 · cited 1×
“Moreover, since diffusion decreases with increasing molecular weight (Masaro and Zhu 1999), dye diffusion from NPs was negligible on account of the high molecular weight of the probes used.”
Background
Cited by
DLS and zeta potential – What they are and what they are not?
Bhattacharjee, S. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.06.017 · Cited by 4,702
Polymeric Nanoparticles: Production, Characterization, Toxicology and Ecotoxicology
Zielińska, A., Carreiró, F., Oliveira, A. M., Neves, A., Pires, B., Venkatesh, D. N., Durazzo, A., Lucarini, M., Eder, P., Silva, A. M., et al. (2020) · Molecules · doi:10.3390/molecules25163731 · Cited by 1,560
Polymeric nanoparticles: the future of nanomedicine
Banik, B. L., Fattahi, P., & Brown, J. L. (2016) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1364 · Cited by 485
Rai, R., Alwani, S., & Badea, I. (2019) · Polymers · doi:10.3390/polym11040745 · Cited by 350
“PMMA NPs showed higher stability in serum and other organ homogenates as compared to PLA NPs due to higher surface charges [114].”
BackgroundThe Biomolecular Corona of Lipid Nanoparticles for Gene Therapy
Francia, V., Schiffelers, R. M., Cullis, P. R., & Witzigmann, D. (2020) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.0c00366 · Cited by 299
Pahuja, R., Seth, K., Shukla, A., Shukla, R. K., Bhatnagar, P., Chauhan, L. K. S., Saxena, P. N., Arun, J., Chaudhari, B. P., Patel, D. K., et al. (2015) · ACS Nano · doi:10.1021/nn506408v · Cited by 260
Application of flash nanoprecipitation to fabricate poorly water-soluble drug nanoparticles
Tao, J., Chow, S. F., & Zheng, Y. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2018.11.001 · Cited by 232
Şen Karaman, D., Ercan, U. K., Bakay, E., Topaloğlu, N., & Rosenholm, J. M. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908783 · Cited by 194
Ferrari, R., Sponchioni, M., Morbidelli, M., & Moscatelli, D. (2018) · Nanoscale · doi:10.1039/c8nr05933k · Cited by 189
Self-citation
Metadata
- Authors
- Lazzari, S., Moscatelli, D., Codari, F., Salmona, M., Morbidelli, M., & Diomede, L.
- Venue
- Journal of Nanoparticle Research
- Published
- 2012-06
- Volume
- 14
- Issue
- 6
- Pages
- 920-920
- ISSN
- 1388-0764 (ISSN-L)
- 1572-896X
- OpenAlex
- W2059503044
- Cited by
- 191
- References
- 29
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.