Application of Deep Learning Techniques in Diagnosis of Covid-19 (Coronavirus): A Systematic Review
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Covid-19 is now one of the most incredibly intense and severe illnesses of the twentieth century. Covid-19 has already endangered the lives of millions of people worldwide due to its acute pulmonary effects. Image-based diagnostic techniques like X-ray, CT, and ultrasound are commonly employed to get a quick and reliable clinical condition. Covid-19 identification out of such clinical scans is exceedingly time-consuming, labor-intensive, and susceptible to silly intervention. As a result, radiography imaging approaches using Deep Learning (DL) are consistently employed to achieve great results. Various artificial intelligence-based systems have been developed for the early prediction of coronavirus using radiography pictures. Specific DL methods such as CNN and RNN noticeably extract extremely critical characteristics, primarily in diagnostic imaging. Recent coronavirus studies have used these techniques to utilize radiography image scans significantly. The disease, as well as the present pandemic, was studied using public and private data. A total of 64 pre-trained and custom DL models concerning imaging modality as taxonomies are selected from the studied articles. The constraints relevant to DL-based techniques are the sample selection, network architecture, training with minimal annotated database, and security issues. This includes evaluating causal agents, pathophysiology, immunological reactions, and epidemiological illness. DL-based Covid-19 detection systems are the key focus of this review article. Covid-19 work is intended to be accelerated as a result of this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of uncertainty quantification in deep learning: Techniques, applications and challenges
Abdar, M., Pourpanah, F., Hussain, S., Rezazadegan, D., Liu, L., Ghavamzadeh, M., Fieguth, P., Cao, X., Khosravi, A., Acharya, U. R., et al. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.05.008 · Cited by 3,111 · cited 1×
“The accuracy obtained by these systems is uncertain because they are susceptible to noise and incorrect model interpretation, and the inductive implications inherent in cases of uncertainty[165].”
BackgroundApostolopoulos, I. D., & Mpesiana, T. A. (2020) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-020-00865-4 · Cited by 2,338
Li, L., Qin, L., Xu, Z., Yin, Y., Wang, X., Kong, B., Bai, J., Lu, Y., Fang, Z., Song, Q., et al. (2020) · Radiology · doi:10.1148/radiol.2020200905 · Cited by 1,927
PadChest: A large chest x-ray image dataset with multi-label annotated reports
Bustos, A., Pertusa, A., Salinas, J.-M., & de la Iglesia-Vayá, M. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101797 · Cited by 691
COVID-19 Detection Through Transfer Learning Using Multimodal Imaging Data
Horry, M. J., Chakraborty, S., Paul, M., Ulhaq, A., Pradhan, B., Saha, M., & Shukla, N. (2020) · IEEE Access · doi:10.1109/access.2020.3016780 · Cited by 472 · cited 5×
“CLAHE, HE, and AHE were used, and the picture with contrast limited AHE [65] was employed before the workflow to improve the clarity of ultrasound images [101].”
BackgroundMethodInfluentialViral pneumonia screening on chest X-rays using confidence-aware anomaly detection
Zhang, J., Xie, Y., Pang, G., Liao, Z., Verjans, J., Li, W., Sun, Z., He, J., Li, Y., Shen, C., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3040950 · Cited by 389
Deep Learning applications for COVID-19
Shorten, C., Khoshgoftaar, T. M., & Furht, B. (2021) · Journal of Big Data · doi:10.1186/s40537-020-00392-9 · Cited by 350 · cited 2×
“Using Named Entity Recognition and Relation Extraction tasks, DL accelerates the building of Knowledge Graphs[162].”
BackgroundMethodLarge Dataset of Labeled Optical Coherence Tomography (OCT) and Chest X-Ray Images
Kermany, D. (2018) · Mendeley · doi:10.17632/rscbjbr9sj.3 · Cited by 172
Cited by
Hossain, E., Rana, R., Higgins, N., Soar, J., Barua, P. D., Pisani, A. R., & Turner, K. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106649 · Cited by 407
Zhang, J., Wu, J., Qiu, Y., Song, A., Li, W., Li, X., & Liu, Y. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106517 · Cited by 69
“For example, intelligent image processing methods based on deep learning (DL) have been applied to processing X-ray, CT, ultrasound, and facial images for diagnosing diseases such as COVID-19 detection [4 – 6], paralysis assessment [7,8], and autism screening [9].”
Fang, S., Hong, S., Li, Q., Li, P., Coats, T., Zou, B., & Kong, G. (2025) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2024.105680 · Cited by 5
Metadata
- Authors
- Bhosale, Y. H., & Patnaik, K. S.
- Venue
- Neural Processing Letters
- Published
- 2022-09-16
- Volume
- 55
- Issue
- 3
- Pages
- 3551-3603
- ISSN
- 1370-4621 (ISSN-L)
- 1573-773X
- OpenAlex
- W4296197501
- Cited by
- 101
- References
- 8
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Deep Learning Techniques in Diagnosis of Covid-19 (Coronavirus): A Systematic Review. https://app.cochat.ai/papers/10.1007/s11063-022-11023-0
- The paper
- Bhosale, Y. H., & Patnaik, K. S. (2023). Application of Deep Learning Techniques in Diagnosis of Covid-19 (Coronavirus): A Systematic Review. Neural Processing Letters. https://doi.org/10.1007/s11063-022-11023-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.