Acidic Microclimate pH Distribution in PLGA Microspheres Monitored by Confocal Laser Scanning Microscopy
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PurposeThe acidic microclimate pH (µpH) distribution inside poly(lactic-co-glycolic acid) (PLGA) microspheres was monitored quantitatively as a function of several formulation variables.MethodsA ratiometric method by confocal laser scanning microscopy with Lysosensor yellow/blue® dextran was adapted from those previously reported, and µpH distribution kinetics inside microspheres was examined during incubation under physiologic conditions for 4 weeks. Effects of PLGA molecular weight (MW) and lactic/glycolic acid ratio, microspheres size and preparation method, and polymer blending with poly(ethylene glycol) (PEG) were evaluated.ResultsµpH kinetics was accurately sensed over a broadly acidic range (2.8 < µpH < 5.8) and was more acidic and variable inside PLGA with lower MW and lactic/glycolic acid ratio. Lower µpH was found in larger microspheres of lower MW polymers, but size effects for lactic-rich polymers were insignificant during 4 weeks. Microspheres prepared by the oil-in-oil emulsion method were less acidic than those prepared by double emulsion, and blending PLGA 50/50 with 20% PEG increased µpH significantly (µpH > 5 throughout incubation).ConclusionsCoupling this method with that previously developed (SNARF-1® dextran for µpH 5.8–8.0) should provide microclimate pH mapping over the entire useful pH range (2.8–8.0) for optimization of PLGA delivery of pH-sensitive bioactive substances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Buffers for pH and Metal Ion Control
Perrin, D. D., & Dempsey, B. (1979) · Springer eBooks · doi:10.1007/978-94-009-5874-6 · Cited by 987
Biologically erodable microspheres as potential oral drug delivery systems
Mathiowitz, E., Jacob, J. S., Jong, Y. S., Carino, G. P., Chickering, D. E., Chaturvedi, P., Santos, C. A., Vijayaraghavan, K., Montgomery, S., Bassett, M., et al. (1997) · Nature · doi:10.1038/386410a0 · Cited by 823
Preparation of microspheres by the solvent evaporation technique
O'Donnell, P. B., & McGinity, J. W. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00049-5 · Cited by 806 · cited 1×
“, lactic/ glycolic acid ratio) (25) and molecular weight (26), preparation method (27), and blending with other polymers (28) all play the important roles in affecting protein release and stability from PLGA microspheres.”
BackgroundFu, K., Pack, D. W., Klibanov, A. M., & Langer, R. (2000) · Pharmaceutical Research · doi:10.1023/a:1007582911958 · Cited by 764 · cited 3×
“The critical importance of the use of dye conjugated with high molecular weight (10 kDa) dextran is to make the dye a long-term tracer and water-soluble macromolecule, which can prevent dye leaching out from polymer, and localize the dye in the aqueous pores similar to the behavior of proteins inside polymer delivery…”
BackgroundMethodDegradation of poly(lactic-co-glycolic acid) microspheres: Effect of copolymer composition
Park, T. G. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93575-x · Cited by 642
Stabilization of proteins encapsulated in injectable poly (lactide- co-glycolide)
Zhu, G., Mallery, S. R., & Schwendeman, S. P. (2000) · Nature Biotechnology · doi:10.1038/71916 · Cited by 609 · cited 2×
“Controlling μpH by co-encapsulation of poorly soluble bases in the polymer system improved protein stability and release kinetics, as demonstrated in studies with bone morphogenetic protein-2 (16), basic fibroblast growth factor (16), tetanus toxoid (17), and tissue plasminogen activator (18).”
BackgroundSelf-citationImproving protein therapeutics with sustained-release formulations
Putney, S. D., & Burke, P. A. (1998) · Nature Biotechnology · doi:10.1038/nbt0298-153 · Cited by 460
Tracy, M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00002-2 · Cited by 411 · cited 1×
“012 day for 50/50, 85/15, 100/0, respectively (33)).”
Biodegradable Microspheres in Drug Delivery
Okada, H., & Toguchi, H. (1995) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v12.i1.10 · Cited by 397
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
The mechanisms of drug release in poly(lactic-co-glycolic acid)-based drug delivery systems—A review
Fredenberg, S., Wahlgren, M., Reslow, M., & Axelsson, A. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.05.049 · Cited by 1,286
Functional aliphatic polyesters for biomedical and pharmaceutical applications
Seyednejad, H., Ghassemi, A. H., van Nostrum, C. F., Vermonden, T., & Hennink, W. E. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.12.016 · Cited by 425
Ford Versypt, A. N., Pack, D. W., & Braatz, R. D. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.10.015 · Cited by 345
Injectable controlled release depots for large molecules
Schwendeman, S. P., Shah, R. B., Bailey, B. A., & Schwendeman, A. S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.057 · Cited by 206
“0 (SNARF1-dextran) [115] by utilizing a single dye and careful signal processing to create a Gaussian distribution of the standard pH images [114].”
MethodSelf-citationBiodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.751371 · Cited by 171
“Among the polylactic/polyglycolic acid carriers, the co-polymer PLGA shows the best release characteristics determined by bulk erosion, but all carriers are known to produce acidic degradation products that can lead to bone resorption [95-97].”
BackgroundBachelder, E. M., Pino, E. N., & Ainslie, K. M. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00532 · Cited by 160
Cai, W., Wu, J., Xi, C., & Meyerhoff, M. E. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.07.027 · Cited by 77
Fundamental insights in PLGA degradation from thin film studies
Machatschek, R., & Lendlein, A. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.044 · Cited by 73
“When the reaction products are not removed from the material, the concentration of acids increases, leading to a decrease of the micro-pH [6,7].”
BackgroundHanda, H., Brisbois, E. J., Major, T. C., Refahiyat, L., Amoako, K. A., Annich, G. M., Bartlett, R. H., & Meyerhoff, M. E. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20277a · Cited by 64
Nanomaterials: Breaking through the bottleneck of tumor immunotherapy
Kang, Y., & Li, S. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.123159 · Cited by 61
Luo, L., Qin, T., Huang, Y., Zheng, S., Bo, R., Liu, Z., Xing, J., Hu, Y., Liu, J., & Wang, D. (2017) · Drug Delivery · doi:10.1080/10717544.2017.1359861 · Cited by 47
“The cell samples were mounted with coverslips and sealed using 50% glycerin (Ding & Schwendeman, 2008).”
Method
Metadata
- Authors
- Ding, A. G., & Schwendeman, S. P.
- Venue
- Pharmaceutical Research
- Published
- 2008-07-12
- Volume
- 25
- Issue
- 9
- Pages
- 2041-2052
- ISSN
- 0724-8741 (ISSN-L)
- 1573-904X
- OpenAlex
- W2083393052
- Cited by
- 163
- References
- 34
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.