A study on a non-contacting respiration signal monitoring system using Doppler ultrasound
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We proposed non-contacting respiration signal monitoring system for sleep apnea syndrome. Experiments were conducted by emitting 40 kHz ultrasound beam, which is set tone burst mode by 1 ms period to a subject chest. Normal respiration condition and a simulated sleep apnea syndrome condition were measured while subjects were holding breath. To obtain the actual respiration signal from the raw signal, ultrasound attenuation characteristics were considered. The Doppler ultrasound signal was detectable once the received signal obtained by demodulation circuits passed through a low pass filter (LPF). The signal's ripples were eliminated by moving average method and the signal's peaks were detected by phase portrait reconstruction method to measure the respiration rate.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultrasound sensors can be used to detect body movement and breathing patterns during sleep54,69,70.”
From The future of sleep health: a data-driven revolution in sleep science and medicine (2020) · cites this paper as [69]
Citations
Cites
A novel method for the detection of apnea and hypopnea events in respiration signals
Varady, P., Micsik, T., Benedek, S., & Benyo, Z. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.802009 · Cited by 197 · cited 1×
“Sleep apnea syndrome (SAS) is a sleep disorder widely found in modern society [10].”
BackgroundImproved ultrasonic detection using the analytic signal magnitude
Gammell, P. M. (1981) · Ultrasonics · doi:10.1016/0041-624x(81)90111-6 · Cited by 104 · cited 1×
“The principle of measuring respiration signals by using ultrasonic attenuation characteristics [2] is that the amplitude of the reflected ultrasonic signal is changed by the chest displacement during breathing exercise.”
BackgroundNon-contact respiratory monitoring system using a ceiling-attached microwave antenna
Uenoyama, M., Matsui, T., Yamada, K., Suzuki, S. V., Takase, B., Suzuki, S., Ishihara, M., & Kawakami, M. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0091-8 · Cited by 95 · cited 4×
“Especially, respiration rate is an important parameter, which has to be monitored for healthy individuals and patients who have to be looked after by physicians, alike [9].”
BackgroundMethodInfluentialUnconstrained cardiorespiratory and body movement monitoring system for home care
Niizeki, K., Nishidate, I., Uchida, K., & Kuwahara, M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02430948 · Cited by 65 · cited 1×
“With living circumstance change, many researchers have been studying on unconstrained measurement and monitoring methods of individual’s vital signs [7, 9, 5, 6].”
BackgroundAnalysis of Breathing Air Flow Patterns in Thermal Imaging
Fei, J., & Pavlidis, I. T. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260117 · Cited by 61 · cited 1×
“Several novel methods have been devised for respiration signal monitoring, in a non-contacting way, such as using microwave antenna [9], thermal infrared imaging [1] and non-restrictive visual method [5].”
MethodTanaka, S., Matsumoto, Y., & Wakimoto, K. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348132 · Cited by 52 · cited 1×
“With living circumstance change, many researchers have been studying on unconstrained measurement and monitoring methods of individual’s vital signs [7, 9, 5, 6].”
BackgroundA Real Time QRS Detection Using Delay-Coordinate Mapping for the Microcontroller Implementation
Lee, J., Kim, K.-S., Lee, B., Lee, B., & Lee, M. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1523030 · Cited by 47 · cited 3×
“This method uses a time-delay coordinates and moves the system’s state variable without effecting the dynamic variable thus, providing an equal phase locus [4].”
BackgroundMethodInfluentialSelf-citationNon-restrictive visual respiration monitoring
Nakai, H., Ishihara, K., Miyake, Y., & Watanabe, M. O. (2002) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.2000.903001 · Cited by 12 · cited 2×
“Several novel methods have been devised for respiration signal monitoring, in a non-contacting way, such as using microwave antenna [9], thermal infrared imaging [1] and non-restrictive visual method [5].”
BackgroundMethodMcIntire, L. V. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1433492 · Cited by 10
Research works printed but not linked: 2
- Kim DS (2003) Clinical physiology, vol 540. Korea Medical Book Publisher, pp 549–551
- Takens F (1980) Lectures Notes in Mathematics, vol 898, Spinger, Heidelberg, p 230
Cited by
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
Noncontact Respiration Rate Measurement System Using an Ultrasonic Proximity Sensor
Min, S. D., Kim, J. K., Shin, H. S., Yun, Y. H., Lee, C. K., & Lee, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2044239 · Cited by 168
“The work presented in this paper is a continuation of our previous study [13], using a higher frequency sensor yielding improved measurement resolution and less susceptibility to background noise.”
MethodResultSelf-citationContact and Remote Breathing Rate Monitoring Techniques: A Review
Ali, M., Elsayed, A., Mendez, A., Savaria, Y., & Sawan, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3072607 · Cited by 114
“Ultrasound sensors can be either in close contact with the body [56] or separated [57], [58].”
InfluentialKhanam, F.-T.-Z., Al‐Naji, A., & Chahl, J. (2019) · Applied Sciences · doi:10.3390/app9204474 · Cited by 107
An Ultrasonic Contactless Sensor for Breathing Monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J.-M. (2014) · Sensors · doi:10.3390/s140815371 · Cited by 102
“Electromagnetic waves can sense chest movement by Doppler effect [7 –10] or by analyzing the signal backscattered by breathing movements [11] and ultrasound waves telemeters permits detection of small body displacements during respiration [12,13].”
BackgroundReal Time Apnoea Monitoring of Children Using the Microsoft Kinect Sensor: A Pilot Study
Al‐Naji, A., Gibson, K., Lee, S., & Chahl, J. (2017) · Sensors · doi:10.3390/s17020286 · Cited by 89
Unobtrusive Sleep Monitoring Using Cardiac, Breathing and Movements Activities: An Exhaustive Review
Matar, G., Lina, J., Carrier, J., & Kaddoum, G. (2018) · IEEE Access · doi:10.1109/access.2018.2865487 · Cited by 80
Suzuki, S. V., Matsui, T., Imuta, H., Uenoyama, M., Yura, H., Ishihara, M., & Kawakami, M. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0298-3 · Cited by 61
Thermal image processing for real‐time non‐contact respiration rate monitoring
Alkali, A. H., Saatchi, R., Elphick, H., & Burke, D. P. (2016) · IET Circuits Devices & Systems · doi:10.1049/iet-cds.2016.0143 · Cited by 56
“Mostafa et al. [21] reported a method that detected and tracked a facial region for respiration rate monitoring.”
Wireless Wearable Ultrasound Sensor on a Paper Substrate to Characterize Respiratory Behavior
Chen, A., Halton, A. J., Rhoades, R. D., Booth, J. C., Shi, X., Bu, X., Wu, N., & Chae, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00043 · Cited by 37
Al‐Naji, A., Al-Askery, A. J., Gharghan, S. K., & Chahl, J. (2019) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan8020032 · Cited by 36
“[34] proposed a contactless breathing monitoring system for sleep apnea syndrome by emitting a 40 kHz ultrasound beam on the thorax region at a short distance of less than 0.”
BackgroundMedical Devices for Measuring Respiratory Rate in Children: a Review
Daw, W. (2016) · Journal of Advances in Biomedical Engineering and Technology · doi:10.15379/2409-3394.2016.03.01.04 · Cited by 35
“Ultrasound has been used to measure respiratory rate in a number of different ways [35, 36].”
New tracheal sound feature for apnoea analysis
Kulkas, A., Huupponen, E., Virkkala, J., Tenhunen, M. L., Saastamoinen, A., Rauhala, E., & Himanen, S. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0446-z · Cited by 33
“toring [15], analysis of non-linear features from nocturnal oxygen saturation [13], and ECG based respiratory analysis”
MethodFacial Tracking in Thermal Images for Real-Time Noncontact Respiration Rate Monitoring
Alkali, A. H., Saatchi, R., Elphick, H., & Burke, D. P. (2013) · UKSim European Symposium on Computer Modeling and Simulation (EMS) · doi:10.1109/ems.2013.46 · Cited by 32
“A method to monitor respiration and detect sleep apnoea using an ultrasound was developed by [7].”
MethodSümbül, H., Yüzer, A. H., & Şekeroğlu, K. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-021-02492-x · Cited by 25
Contactless Diseases Diagnoses Using Wireless Communication Sensing: Methods and Challenges Survey
Abuali, N. A., Rehman, M., Mumtaz, S., Khan, M. B., Hayajneh, M., Ullah, F., & Shah, R. A. (2024) · ACM Computing Surveys · doi:10.1145/3648352 · Cited by 20
“Min et al. [ 86 ] and Mohammed et al. [ 87 ] proposed solutions to the blind spot problem.”
BackgroundDesign, construction and evaluation of an ambulatory device for screening of sleep apnea
Tiihonen, P., Pääkkönen, A. K., Mervaala, E., Hukkanen, T., & Töyräs, J. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0418-8 · Cited by 17
“In addition to the Type 1‐4 devices many other approaches including monitoring of tracheal sound patterns [9], application of respiration signal monitoring system using Doppler ultrasound [ 12 ] and evaluation of non-linear dynamics of human periodic breathing [20] have been proposed.”
MethodPark, S., & Shin, H. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2695565 · Cited by 16
“sensitive textiles [9], [10], piezoelectric films [11], [12], ultrasound [13], ultra-wide band (UWB) radar [14], opti-”
BackgroundRespiratory Bidirectional Ultrasonic TOF Flow Sensor Resilience to Ambient Temperature Fluctuations
Begin, G., Al-Tamimi, K. M., Alamdari, H. H., Roach, D. C., Schmidt, M., & El‐Sankary, K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3088713 · Cited by 14
New Paths in Respiratory Sleep Medicine
Penzel, T., Dietz-Terjung, S., Woehrle, H., & Schöbel, C. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.006 · Cited by 13
An ultrasonic contactless sensor for breathing monitoring
Arlotto, P., Grimaldi, M., Naeck, R., & Ginoux, J. (2015) · Sleep Medicine · doi:10.1016/j.sleep.2015.02.075 · Cited by 12
Surface imaging for real‐time patient respiratory function assessment in intensive care
Nazir, S., Pateau, V., Bert, J., Clement, J. F., Fayad, H. J., L’Her, E., & Visvikis, D. (2020) · Medical Physics · doi:10.1002/mp.14557 · Cited by 9
Kulkas, A., Huupponen, E., Virkkala, J., Saastamoinen, A., Rauhala, E., Tenhunen, M. L., & Himanen, S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/3/010 · Cited by 9
Eyes' corners detection in infrared images for real-time noncontact respiration rate monitoring
Alkali, A. H., Saatchi, R., Elphick, H., & Burke, D. P. (2014) · World Congress on Computer Applications and Information Systems (WCCAIS) · doi:10.1109/wccais.2014.6916570 · Cited by 9
“The changes in chest position during respiration was utilised in [6-12].”
MethodAlamri, A., & Alamri, S. (2021) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2021.015198 · Cited by 8
Wireless Wearable Ultrasound Sensor to Characterize Respiratory Behavior
Chen, A., Rhoades, R. D., Halton, A. J., Booth, J. C., Shi, X., Bu, X., Wu, N., & Chae, J. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1803-5_36 · Cited by 7
Al-Abed, M. A., Antich, P. P., Watenpaugh, D. E., & Behbehani, K. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.019 · Cited by 7
Chattopadhyay, M., & Chakraborty, D. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-21671-3_7 · Cited by 4
Respiratory rate estimation using nostril detection in thermal video streams
Mocanu, B., Ţarălungă, D. D., Țapu, R., & Tapu, E. (2017) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb.2017.7995396 · Cited by 2
“Min et al developed in [3] a system based on ultrasounds attenuation characteristics, for sleep apnea syndrome.”
BackgroundRemote depth-based photoplethysmography in pulmonary function testing
Soleimani, V. (2018) · Bristol Research (University of Bristol) · Cited by 2
Jeger‐Madiot, N. (2017) · theses.fr (ABES) · doi:10.70675/1c0d8f4az2f27z4c6eza9f2zcbc8d27e92dd · Cited by 2
Impact of Device Placement on Non-Contact Respiratory Monitoring Using Channel State Information
Jin, Y., Shao, C., Wang, Y., Hu, B., Hu, H., & Gao, Y. (2024) · International Conference on Information Communication and Signal Processing (ICICSP) · doi:10.1109/icicsp62589.2024.10809096 · Cited by 1
“In addition, ultrasonic-based sensing methods are also under investigation [10].”
da Costa, C. F., Oliveira, N. V., Júnior, E. P. S., & de Melo, P. L. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1044/1/012002 · Cited by 1
Development of hardware and algorithms for a multi-functional capacitive proximity sensing system
Xia, F. (2018) · Summit (Simon Fraser University) · Cited by 1
Measuring Respiratory Rate in Children
Daw, W. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 1
Abdulqader, T. (2020) · Sheffield Hallam University · doi:10.7190/shu-thesis-00415 · Cited by 1
World Congress on Medical Physics and Biomedical Engineering (WC2006, Seoul)
Woo, E. J., Kim, H.-J., & Spaan, J. A. E. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0284-9
“The growing population of elderly in our society requires new technologies for monitoring and preventing disease [4, 15].”
BackgroundInfrared Imaging for Real-Time Noncontact Respiration Monitoring
Alkali, A. H., Saatchi, R., Elphick, H., & Burke, D. P. (2014) · International Conference on Quantitative InfraRed Thermography (QIRT) · doi:10.21611/qirt.2014.218
Sensitivity of single coil electromagnetic sensors for breathing measurements
Seeton, R. (2009) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2009-09361
“There are various other non-invasive respiratory monitoring techniques that have been studied include using a ceiling-attached microwave antenna to monitor respiratory signs [32], using a ultrasonic sensor to monitor for sleep apnea [20], using thermal infrared imaging to monitor breathing by detecting CO2 emissions […”
MethodNon invasive monitoring of the cardio respiratory activity
Baltag, O., Rau, C. M., & Banarescu, A. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03885-3_147
Digital phenotyping through multimodal, unobtrusive sensing
Perez-Pozuelo, I. (2020) · Apollo (University of Cambridge) · doi:10.17863/cam.68489
Optimization of Ultrasonic Respiratory Signals based on Supervised Learning
Chen, J. C., Dang, Z., Li, L., & Dang, F. (2023) · IEEE International Conference on Parallel and Distributed Systems (ICPADS) · doi:10.1109/icpads56603.2022.00053
“Specialized ultrasonic sensors were used in past studies to monitor respiration signal [5], [11].”
BackgroundMethodExploring Low Cost Non-Contact Detection of Biosignals for HCIPreprint
Tremmel, C., Bodala, I. P., & schraefel, M. C. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2304.10555
“Similar to remote HR tracking, there are many different approaches to remotely detect the respiratory rate such as techniques based on radar [55, 7], interferometry [29], temperature [4], humidity [54], ultrasound [30], rPPG [48] or camera [57].”
MethodNeue Verfahren in der respiratorischen Schlafmedizin
Dietz-Terjung, S., Wildenauer, A., Eggert, T., Schulte, T., Braun, M., Sutharsan, S., Welsner, M., Straßburg, S., Schöbel, C., & Hienzsch, A. (2023) · Pneumo News · doi:10.1007/s15033-023-3560-y
Wireless Wearable Sensor to Characterize Respiratory Behaviors
(2020) · Arizona State University Library Digital Repository (Arizona State University)
Applications of computer vision for remote sensing of infant and adult physiology
Khanam, F.-T.-Z. (2023) · Adelaide Research & Scholarship (AR&S) (University of Adelaide)
Metadata
- Authors
- Min, S. D., Yoon, D. J., Yoon, S. W., Yun, Y. H., & Lee, M.
- Affiliations
- Yonsei University (KR)
- Corresponding author
- Lee, Myoungho
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2007-09-06
- Volume
- 45
- Issue
- 11
- Pages
- 1113-1119
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2072442733
- Semantic Scholar
- 8ad3af7195513d5c47e53677e98f20064e15cde6
- Cited by
- 40
- References
- 9
- Citations by year
- 2024: 2 · 2023: 2 · 2022: 1 · 2021: 5 · 2020: 3 · 2019: 3 · 2018: 3 · 2017: 5 · 2016: 2 · 2015: 2 · 2014: 3 · 2013: 1
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- Doppler ultrasound, sleep apnea, 40 kHz ultrasound, ultrasonic attenuation, low-pass filtering, moving average smoothing, peak detection, respiratory rate measurement
- MeSH terms
- Algorithms, Humans, Monitoring, Physiologic, Respiration, Signal Processing, Computer-Assisted, Sleep Apnea Syndromes, Ultrasonography, Doppler
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.