CoChat

The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.

Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair

Breininger, Katharina, Albarqouni, Shadi, Kurzendorfer, Tanja, Pfister, Marcus, Kowarschik, Markus, Maier, Andreas · 2018 · International Journal of Computer Assisted Radiology and Surgery

Abstract

Purpose Fusion of preoperative data with intraoperative X-ray images has proven the potential to reduce radiation exposure and contrast agent, especially for complex endovascular aortic repair (EVAR). Due to patient movement and introduced devices that deform the vasculature, the fusion can become inaccurate. This is usually detected by comparing the preoperative information with the contrasted vessel. To avoid repeated use of iodine, comparison with an implanted stent can be used to adjust the fusion. However, detecting the stent automatically without the use of contrast is challenging as only thin stent wires are visible. Method We propose a fast, learning-based method to segment aortic stents in single uncontrasted X-ray images. To this end, we employ a fully convolutional network with residual units. Additionally, we investigate whether incorporation of prior knowledge improves the segmentation. Results We use 36 X-ray images acquired during EVAR for training and evaluate the segmentation on 27 additional images. We achieve a Dice coefficient of 0.933 (AUC 0.996) when using X-ray alone, and 0.918 (AUC 0.993) and 0.888 (AUC 0.99) when adding the preoperative model, and information about the expected wire width, respectively. Conclusion The proposed method is fully automatic, fast and segments aortic stent grafts in fluoroscopic images with high accuracy. The quality and performance of the segmentation will allow for an intraoperative comparison with the preoperative inform…

Overview

Integrity signals

Registry

Crossref · 10.1007/s11548-018-1779-6

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. Reiml S, Pfister M, Toth D, Maier A, Hoffmann M, Kowarschik M, Hornegger J (2015) Automatic detection of stent graft markers in 2-D fluoroscopy images. In: Joint MICCAI workshop on computing and visualisation for intravascular imaging and computer-assisted stenting, pp 34–41

Cited by

See all 43

Metadata

Authors
Breininger, K., Albarqouni, S., Kurzendorfer, T., Pfister, M., Kowarschik, M., & Maier, A.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • Technical University of Munich (DE)
  • Siemens Healthineers (Germany) (DE)
Corresponding author
Breininger, Katharina
Venue
International Journal of Computer Assisted Radiology and Surgery
Published
2018-05-19
Volume
13
Issue
8
Pages
1221-1231
ISSN
  • 1861-6410 (ISSN-L)
  • 1861-6429
OpenAlex
W2804499907
Cited by
38
References
28
Citations by year
2026: 5 · 2025: 6 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 8 · 2018: 1
FWCI
2.25
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • International Journal of Computer Assisted Radiology and Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
  • Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
Keywords
endovascular aortic repair, X-ray fluoroscopy, fully convolutional network, residual blocks, covered stent, radiation dose reduction, contrast agent reduction
MeSH terms
Animals, Aorta, Blood Vessel Prosthesis, Fluoroscopy, Humans, Tomography, X-Ray Computed, Stents, Treatment Outcome, Endovascular Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair. https://app.cochat.ai/papers/10.1007/s11548-018-1779-6
The paper
Breininger, K., Albarqouni, S., Kurzendorfer, T., Pfister, M., Kowarschik, M., & Maier, A. (2018). Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-018-1779-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.