Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
Purpose Fusion of preoperative data with intraoperative X-ray images has proven the potential to reduce radiation exposure and contrast agent, especially for complex endovascular aortic repair (EVAR). Due to patient movement and introduced devices that deform the vasculature, the fusion can become inaccurate. This is usually detected by comparing the preoperative information with the contrasted vessel. To avoid repeated use of iodine, comparison with an implanted stent can be used to adjust the fusion. However, detecting the stent automatically without the use of contrast is challenging as only thin stent wires are visible. Method We propose a fast, learning-based method to segment aortic stents in single uncontrasted X-ray images. To this end, we employ a fully convolutional network with residual units. Additionally, we investigate whether incorporation of prior knowledge improves the segmentation. Results We use 36 X-ray images acquired during EVAR for training and evaluate the segmentation on 27 additional images. We achieve a Dice coefficient of 0.933 (AUC 0.996) when using X-ray alone, and 0.918 (AUC 0.993) and 0.888 (AUC 0.99) when adding the preoperative model, and information about the expected wire width, respectively. Conclusion The proposed method is fully automatic, fast and segments aortic stent grafts in fluoroscopic images with high accuracy. The quality and performance of the segmentation will allow for an intraoperative comparison with the preoperative inform…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, since existing large-scale hip datasets have focused on 3D image modalities and pre and postoperative radiography, rather than intraoperative fluoroscopy [12], applications of CNNs to fluoroscopy have been mostly limited to recognizing surgical instruments and tools [13-16].”
From Automatic Annotation of Hip Anatomy in Fluoroscopy for Robust and Efficient 2D/3D Registration (2020) · cites this paper as [15]
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Fully convolutional networks for semantic segmentation
Long, J., Shelhamer, E., & Darrell, T. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298965 · Cited by 38,834
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation
Milletari, F., Navab, N., & Ahmadi, S.-A. (2016) · 2016 Fourth International Conference on 3D Vision (3DV) · doi:10.1109/3dv.2016.79 · Cited by 11,931
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2015) · arXiv · doi:10.48550/arxiv.1512.03385 · Cited by 4,196
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Striving for Simplicity: The All Convolutional Net
Springenberg, J. T., Dosovitskiy, A., Brox, T., & Riedmiller, M. (2014) · arXiv · doi:10.48550/arxiv.1412.6806 · Cited by 3,447
Deconvolution and Checkerboard Artifacts
Odena, A., Dumoulin, V., & Olah, C. (2016) · Distill · doi:10.23915/distill.00003 · Cited by 1,640
Radio frequency interference mitigation using deep convolutional neural networks
Akeret, J., Chang, C., Lucchi, A., & Refregier, A. (2017) · Astronomy and Computing · doi:10.1016/j.ascom.2017.01.002 · Cited by 202
Impact of Hybrid Rooms with Image Fusion on Radiation Exposure during Endovascular Aortic Repair
Hertault, A., Maurel, B., Sobocinski, J., Martin Gonzalez, T., Le Roux, M., Azzaoui, R., Midulla, M., & Haulon, S. (2014) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2014.05.026 · Cited by 184
Tacher, V., Lin, M., Desgranges, P., Deux, J., Grünhagen, T., Becquemin, J., Luciani, A., Rahmouni, A., & Kobeiter, H. (2013) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2013.07.016 · Cited by 168
McNally, M. M., Scali, S. T., Feezor, R. J., Neal, D. W., Huber, T. S., & Beck, A. W. (2014) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2014.07.097 · Cited by 150
Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy
Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8_65 · Cited by 102
Gindre, J., Bel‐Brunon, A., Rochette, M., Lucas, A., Kaladji, A., Haigron, P., & Combescure, A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2587362 · Cited by 61
Kauffmann, C., Douane, F., Thérasse, É., Lessard, S., Elkouri, S., Gilbert, P., Beaudoin, N., Pfister, M., Blair, J.-F., & Soulez, G. (2015) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2014.12.019 · Cited by 59
Self-citationFusion Imaging to Support Endovascular Aneurysm Repair Using 3D-3D Registration
Schulz, C. J., Schmitt, M., Böckler, D., & Geisbüsch, P. (2016) · Journal of Endovascular Therapy · doi:10.1177/1526602816660327 · Cited by 51
Electrophysiology Catheter Detection and Reconstruction From Two Views in Fluoroscopic Images
Hoffmann, M., Brost, A., Koch, M., Bourier, F. J., Maier, A., Kurzidim, K. W., Strobel, N. K., & Joachim Hornegger, A. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2482539 · Cited by 39
Self-citationAdaption of 3D Models to 2D X-Ray Images during Endovascular Abdominal Aneurysm Repair
Toth, D. F., Pfister, M., Maier, A., Kowarschik, M., & Joachim Hornegger, A. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24553-9_42 · Cited by 34
Self-citation3D Stent Recovery from One X-Ray Projection
Demirci, S., Bigdelou, A., Wang, L., Wachinger, C., Baust, M., Tibrewal, R., Ghotbi, R., Eckstein, H., & Navab, N. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23623-5_23 · Cited by 32
CathNets: Detection and Single-View Depth Prediction of Catheter Electrodes
Baur, C., Albarqouni, S., Demirci, S., Navab, N., & Fallavollita, P. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-43775-0_4 · Cited by 24
Self-citationA comprehensive study of stent visualization enhancement in X-ray images by image processing means
Bismuth, V., Vaillant, R., Funck, F., Guillard, N., & Najman, L. A. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.03.002 · Cited by 20
Lessard, S., Kauffmann, C., Pfister, M., Cloutier, G., Thérasse, É., de Guise, J. A., & Soulez, G. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.07.007 · Cited by 19
Self-citationAutomatic segmentation of the wire frame of stent grafts from CT data
Klein, A., van der Vliet, J. A., Oostveen, L. J., Hoogeveen, Y. L., Kool, L. J. S., Renema, W. K. J., & Slump, C. H. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.05.015 · Cited by 19
Online tracking of interventional devices for endovascular aortic repair
Volpi, D., Sarhan, M. H., Ghotbi, R., Navab, N., Mateus, D., & Demirci, S. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1217-y · Cited by 18
Panuccio, G., Torsello, G. F., Pfister, M., Bisdas, T., Bosiers, M. J., Torsello, G. B., & Austermann, M. J. (2016) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2016.05.100 · Cited by 16
Self-citationReal Time Assistance for Stent Positioning and Assessment by Self-initialized Tracking
Chen, T., Wang, Y., Durlak, P., & Comaniciu, D. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-33415-3_50 · Cited by 6
Research works printed but not linked: 1
- Reiml S, Pfister M, Toth D, Maier A, Hoffmann M, Kowarschik M, Hornegger J (2015) Automatic detection of stent graft markers in 2-D fluoroscopy images. In: Joint MICCAI workshop on computing and visualisation for intravascular imaging and computer-assisted stenting, pp 34–41
Cited by
A gentle introduction to deep learning in medical image processing
Maier, A., Syben, C., Lasser, T., & Riess, C. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.12.003 · Cited by 515
Self-citationAutomatic Annotation of Hip Anatomy in Fluoroscopy for Robust and Efficient 2D/3D Registration
Grupp, R. B., Unberath, M., Gao, C., Hegeman, R. A., Murphy, R. J., Alexander, C. P., Otake, Y., McArthur, B. A., Armand, M., & Taylor, R. H. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02162-7 · Cited by 83
“However, since existing large-scale hip datasets have focused on 3D image modalities and pre and postoperative radiography, rather than intraoperative fluoroscopy [12], applications of CNNs to fluoroscopy have been mostly limited to recognizing surgical instruments and tools [13–16].”
BackgroundTransferring deep learning models for cloud detection between Landsat-8 and Proba-V
Mateo‐García, G., Laparra, V., López-Puigdollers, D., & Gómez‐Chova, L. (2019) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2019.11.024 · Cited by 83
Nguyen, A., Kundrat, D., Dagnino, G., Chi, W., Abdelaziz, M. E. M. K., Guo, Y., Ma, Y., Kwok, T. M. Y., Riga, C. V., & Yang, G. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9197307 · Cited by 51
Deep learning in biomedical informatics
Hung, C. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-85796-3.00011-1 · Cited by 37
Metadata
- Authors
- Breininger, K., Albarqouni, S., Kurzendorfer, T., Pfister, M., Kowarschik, M., & Maier, A.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Technical University of Munich (DE)
- Siemens Healthineers (Germany) (DE)
- Corresponding author
- Breininger, Katharina
- Venue
- International Journal of Computer Assisted Radiology and Surgery
- Published
- 2018-05-19
- Volume
- 13
- Issue
- 8
- Pages
- 1221-1231
- ISSN
- 1861-6410 (ISSN-L)
- 1861-6429
- OpenAlex
- W2804499907
- Cited by
- 38
- References
- 28
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 6 · 2019: 8 · 2018: 1
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- International Journal of Computer Assisted Radiology and Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
- Keywords
- endovascular aortic repair, X-ray fluoroscopy, fully convolutional network, residual blocks, covered stent, radiation dose reduction, contrast agent reduction
- MeSH terms
- Animals, Aorta, Blood Vessel Prosthesis, Fluoroscopy, Humans, Tomography, X-Ray Computed, Stents, Treatment Outcome, Endovascular Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.