Distinction between benign and malignant breast masses at breast ultrasound using deep learning method with convolutional neural network
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Purpose We aimed to use deep learning with convolutional neural network (CNN) to discriminate between benign and malignant breast mass images from ultrasound.Materials and methods We retrospectively gathered 480 images of 96 benign masses and 467 images of 144 malignant masses for training data. Deep learning model was constructed using CNN architecture GoogLeNet and analyzed test data: 48 benign masses, 72 malignant masses. Three radiologists interpreted these test data. Sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) were calculated.Results The CNN model and radiologists had a sensitivity of 0.958 and 0.583-0.917, specificity of 0.925 and 0.604-0.771, and accuracy of 0.925 and 0.658-0.792, respectively. The CNN model had equal or better diagnostic performance compared to radiologists (AUC = 0.913 and 0.728-0.845, p = 0.01-0.14).Conclusion Deep learning with CNN shows high diagnostic performance to discriminate between benign and malignant breast masses on ultrasound.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sixteen studies62,91,92,94,97–107 compared algorithm performance against healthcare professionals.”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [102]
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Going deeper with convolutions
Szegedy, C., Liu, W., Jia, Y., Sermanet, P., Reed, S., Anguelov, D., Erhan, D., Vanhoucke, V., & Rabinovich, A. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298594 · Cited by 48,562
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S., & Szegedy, C. (2015) · arXiv · doi:10.48550/arxiv.1502.03167 · Cited by 27,818
Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics
Kanda, Y. (2013) · Bone Marrow Transplantation · doi:10.1038/bmt.2012.244 · Cited by 18,767
Siegel, R. L., Miller, K. D., & Jemal, A. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21442 · Cited by 16,579
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
Erdogan, D., Heijnen, B. H. M., Bennink, R. J., Kok, M., Dinant, S., Straatsburg, I. H., Gouma, D. J., & van Gulik, T. M. (2004) · Liver International · doi:10.1111/j.1478-3231.2004.00901.x · Cited by 11,700
Shin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Yao, J., Mollura, D., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528162 · Cited by 5,759
Lakhani, P., & Sundaram, B. (2017) · Radiology · doi:10.1148/radiol.2017162326 · Cited by 1,775
Berg, W. A., Campassi, C., Langenberg, P., & Sexton, M. J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.6.1741769 · Cited by 1,273
Deep Learning: A Primer for Radiologists
Chartrand, G., Cheng, P. M., Vorontsov, E., Drozdzal, M., Turcotte, S., Pal, C. J., Kadoury, S., & Tang, A. (2017) · RadioGraphics · doi:10.1148/rg.2017170077 · Cited by 1,115
Deep learning with convolutional neural network in radiology
Yasaka, K., Akai, H., Kunimatsu, A., Kiryu, S., & Abe, O. (2018) · Japanese Journal of Radiology · doi:10.1007/s11604-018-0726-3 · Cited by 368
A deep learning framework for supporting the classification of breast lesions in ultrasound images
Han, S., Kang, H.-K., Jeong, J.-Y., Park, M.-H., Kim, W., Bang, W.-C., & Seong, Y.-K. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa82ec · Cited by 358
Hyperparameter Search in Machine Learning
Claesen, M., & Moor, B. D. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1502.02127 · Cited by 333 · cited 1×
“Conversely, existing deep learning technology can refer “thoughts” up to hundreds of dimensions [23].”
BackgroundDeep learning in mammography and breast histology, an overview and future trends
Hamidinekoo, A., Denton, E., Rampun, A., Honnor, K., & Zwiggelaar, R. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.03.006 · Cited by 273
A Pictorial Review of Changes in the BI-RADS Fifth Edition
Rao, A. A., Feneis, J., Lalonde, C., & Ojeda-Fournier, H. (2016) · RadioGraphics · doi:10.1148/rg.2016150178 · Cited by 228
Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey
Huang, Q., Zhang, F., & Li, X. (2018) · BioMed Research International · doi:10.1155/2018/5137904 · Cited by 206
Shi, J., Zhou, S., Liu, X., Zhang, Q., Lu, M., & Wang, T. (2016) · Neurocomputing · doi:10.1016/j.neucom.2016.01.074 · Cited by 166
Youk, J. H., Son, E. J., Gweon, H. M., Kim, H. H., Park, Y. J., & Kim, J. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.05.020 · Cited by 110
Automated and real-time segmentation of suspicious breast masses using convolutional neural network
Kumar, V., Webb, J. M., Gregory, A., Denis, M. F., Meixner, D. D., Bayat, M., Whaley, D. H., Fatemi, M., & Alizad, A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0195816 · Cited by 110
Stoffel, E., Becker, A. S., Wurnig, M. C., Marcon, M., Ghafoor, S., Berger, N., & Boss, A. (2018) · European Journal of Radiology Open · doi:10.1016/j.ejro.2018.09.002 · Cited by 47
Ultrasound-Guided Percutaneous Breast Biopsy
Newell, M. S., & Mahoney, M. C. (2014) · Techniques in vascular and interventional radiology · doi:10.1053/j.tvir.2013.12.005 · Cited by 40
Current Status of Breast Ultrasound
Kornecki, A. (2010) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2010.07.006 · Cited by 31
How Many of the Biopsy Decisions Taken at Inexperienced Breast Radiology Units Were Correct?
Demircioğlu, Ö., Uluer, M., & Arıbal, E. (2017) · Meme sağlığı dergisi/Meme sağlığı dergisi · doi:10.5152/tjbh.2016.2962 · Cited by 8
Research works printed but not linked: 2
- D’Orsi C, Sickles E, Mendelson E, Morris E. Breast imaging reporting and data system. 5th ed. Reston: American College of Radiology; 2013.
- Yasaka K, Akai H, Kunimatsu A, Kiryu S, Abe O. Deep learning with convolutional neural network in radiology. Jpn J Radiol. 2018;36:257–72. · DOI · Paper page
Cited by
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
A scoping review of transfer learning research on medical image analysis using ImageNet
Morid, M. A., Borjali, A., & Del Fiol, G. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.104115 · Cited by 508
Shen, Y., Shamout, F. E., Oliver, J. R., Witowski, J., Kannan, K., Park, J., Wu, N., Huddleston, C., Wolfson, S., Millet, A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26023-2 · Cited by 270
Artificial intelligence in ultrasound
Shen, Y.-T., Chen, L., Yue, W.-W., & Xu, H.-X. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109717 · Cited by 214
Metadata
- Authors
- Fujioka, T., Kubota, K., Mori, M., Kikuchi, Y., Katsuta, L., Kasahara, M., Oda, G., Ishiba, T., Nakagawa, T., & Tateishi, U.
- Affiliations
- Tokyo Medical and Dental University (JP)
- Corresponding author
- Mori, Mio
- ORCID
- Venue
- Japanese Journal of Radiology
- Published
- 2019-03-19
- Volume
- 37
- Issue
- 6
- Pages
- 466-472
- ISSN
- 1867-1071 (ISSN-L)
- 1867-108X
- OpenAlex
- W2939142770
- Semantic Scholar
- b9a20906f676c32cc58f9c69a9d83c7c25f4cf3a
- Cited by
- 177
- References
- 24
- Citations by year
- 2026: 6 · 2025: 18 · 2024: 26 · 2023: 35 · 2022: 34 · 2021: 25 · 2020: 26 · 2019: 6
- FWCI
- 10.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Japanese Journal of Radiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- KAKENHI-PROJECT (16K10270)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Health Sciences › Medicine › Pathology and Forensic Medicine › Breast Lesions and Carcinomas
- Keywords
- breast ultrasound, breast mass, benign versus malignant differentiation, convolutional neural networks, GoogLeNet, computer-aided diagnosis, radiologist comparison, diagnostic accuracy
- MeSH terms
- Deep Learning, Adult, Aged, Aged, 80 and over, Breast, Breast Neoplasms, Diagnosis, Differential, Female, Humans, Image Interpretation, Computer-Assisted, Male, Middle Aged, Retrospective Studies, ROC Curve, Sensitivity and Specificity, Reproducibility of Results, Databases, Factual, Ultrasonography, Mammary, Neural Networks, Computer, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.