Continuous Glucose Monitoring: Current Use and Future Directions
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) is an emerging technology that provides a continuous measure of interstitial glucose levels. In addition to providing a more complete pattern of glucose excursions, CGMs utilize real-time alarms for thresholds and predictions of hypo- and hyperglycemia, as well as rate of change alarms for rapid glycemic excursions. CGM users have been able to improve glycemic control without increasing their risk of hypoglycemia. Sensor accuracy, reliability, and wearability are important challenges to CGM success and are critical to the development of an artificial pancreas (or closed-loop system).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Davis, E. A., Keating, B., Byrne, G. C., Russell, M., & Jones, T. W. (1997) · Diabetes Care · doi:10.2337/diacare.20.1.22 · Cited by 273
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102
Mediation of in vivo glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96
Ly, T. T., Hewitt, J., Davey, R. J., Lim, E. M., Davis, E. A., & Jones, T. W. (2011) · Diabetes Care · doi:10.2337/dc10-1042 · Cited by 81
Cited by
Biosensors and their widespread impact on human health
Bhatia, D., Paul, S., Acharjee, T., & Ramachairy, S. S. (2024) · Sensors International · doi:10.1016/j.sintl.2023.100257 · Cited by 311
Kumar, R. B., Goren, N. D., Stark, D. E., Wall, D. P., & Longhurst, C. A. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv206 · Cited by 126
“The continuous glucose monitor is a popular sensor technology that enables frequent measurement (5-minute intervals) of interstitial glucose concentration.(20) CGM accuracy is recently approaching that of standard finger-stick glucometers, and its use provides real-time glucose data to patients/parents and retrospecti…”
BackgroundMachine-Learning Based Model to Improve Insulin Bolus Calculation in Type 1 Diabetes Therapy
Noaro, G., Cappon, G., Vettoretti, M., Sparacino, G., Favero, S. D., & Facchinetti, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3004031 · Cited by 57
Klupa, T., Benbenek-Klupa, T., Matejko, B., Mrozinska, S., & Malecki, M. T. (2015) · International Journal of Endocrinology · doi:10.1155/2015/216918 · Cited by 20
“Finally one has to underline, that we have used CGM systems that are still characterized with limited accuracy and reliability [18].”
Background
Metadata
- Authors
- DeSalvo, D., & Buckingham, B.
- Venue
- Current Diabetes Reports
- Published
- 2013-08-14
- Volume
- 13
- Issue
- 5
- Pages
- 657-662
- ISSN
- 1534-4827 (ISSN-L)
- 1539-0829
- OpenAlex
- W2082966849
- Cited by
- 73
- References
- 12
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring: Current Use and Future Directions. https://app.cochat.ai/papers/10.1007/s11892-013-0398-4
- The paper
- DeSalvo, D., & Buckingham, B. (2013). Continuous Glucose Monitoring: Current Use and Future Directions. Current Diabetes Reports. https://doi.org/10.1007/s11892-013-0398-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.