The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty
Open accessAbstract
Multiple differing surgical techniques are currently utilized to perform total knee arthroplasty (TKA). We compared knee arthroplasties performed using either a measured resection or gap balancing technique to determine if either operative technique provides superior coronal plane stability as measured by assessment of the incidence and magnitude of femoral condylar lift-off. We performed 40 TKA using a measured resection technique (20 PCL-retaining and 20 PCL-substituting) and 20 PCL-substituting TKA were implanted using gap balancing. All subjects were analyzed fluoroscopically while performing a deep knee bend. The incidence of coronal instability (femoral condylar lift-off) was then determined using a 3-D model fitting technique. The incidence of lift-off greater than 0.75 mm was 80% (maximum, 2.9 mm) and 70% (maximum, 2.5 mm) for the PCL-retaining and substituting TKA groups performed using measured resection versus 35% (maximum, 0.88 mm) for the gap-balanced group. Lift-off greater than 1 mm occurred in 60% and 45% of the PCL-retaining and -substituting TKA using measured resection versus none in the gap-balanced group. Rotation of the femoral component using a gap balancing technique resulted in better coronal stability which we suggest will improve functional performance and reduce polyethylene wear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berger, R. A., Rubash, H. E., Seel, M. J., THOMPSON, W. H., & Crossett, L. S. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199301000-00008 · Cited by 848
Rotational Landmarks and Sizing of the Distal Femur in Total Knee Arthroplasty
Poilvache, P. L., Insall, J. N., Scuderi, G. R., & Font-Rodriguez, D. E. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199610000-00006 · Cited by 419
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
Self-citationAnatomy of the epicondyles of the distal femur
Griffin, F. M., Math, K., Scuderi, G. R., Insall, J. N., & Poilvache, P. L. (2000) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(00)90739-3 · Cited by 253
Hoff, W. A., Komistek, R. D., Dennis, D. A., Gabriel, S. M., & Walker, S. A. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00009-6 · Cited by 178
Self-citationThe influence of femoral condylar lift-off on the wear of artificial knee joints
Jennings, L. M., Bell, C. J., Ingham, E., Komistek, R. D., Stone, M. H., & Fisher, J. (2007) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim215 · Cited by 73
Self-citation
Cited by
Tarassoli, P., Wood, J. A., Chen, D. B., Griffiths‐Jones, W., Bellemans, J., & MacDessi, S. J. (2022) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-022-07038-8 · Cited by 46
Orsi, A. D., Wakelin, E., Plaskos, C., McMahon, S., & Coffey, S. (2023) · Arthroplasty Today · doi:10.1016/j.artd.2022.101090 · Cited by 30
Metadata
- Authors
- Dennis, D. A., Komistek, R. D., Kim, R. H., & Sharma, A.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2010-01
- Volume
- 468
- Issue
- 1
- Pages
- 102-107
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1999859392
- Cited by
- 262
- References
- 6
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty. https://app.cochat.ai/papers/10.1007/s11999-009-1112-3
- The paper
- Dennis, D. A., Komistek, R. D., Kim, R. H., & Sharma, A. (2010). Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-009-1112-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.