CoChat

Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method

Open access
Chapleau, Julien, Canet, Fanny, Petit, Yvan, Laflamme, G-Yves, Rouleau, Dominique M. · 2011 · Clinical Orthopaedics & Related Research
Cited by 171

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

BACKGROUND: A universal goniometer is commonly used to measure the elbow's ROM and carrying angle; however, some authors question its poor intertester reliability. QUESTIONS/PURPOSES: We (1) assessed the validity of goniometric measurements as compared with radiographic measurements in the evaluation of ROM of the elbow and (2) determined the reliability of both. METHODS: The ROM and carrying angle of 51 healthy subjects (102 elbows) were measured using two methods: with a universal goniometer by one observer three times and on radiographs by two independent examiners. Paired t-test and Pearson's correlation were used to compare and detect the relationship between mean ROM. The maximal error was calculated according to the Bland and Altman method. RESULTS: The intraclass correlation coefficients (ICC) ranged from 0.945 to 0.973 for the goniometric measurements and from 0.980 to 0.991 for the radiographic measurements. The two methods correlated when measuring the total ROM in flexion and extension. The maximal errors of the goniometric measurement were 10.3° for extension, 7.0° for flexion, and 6.5° for carrying angle 95% of the time. We observed differences for maximum flexion, maximal extension, and carrying angle between the methods. CONCLUSION: Both measurement methods differ but they correlate. When measured with a goniometer, the elbow ROM shows a maximal error of approximately 10°. CLINICAL RELEVANCE: The goniometer is a reasonable and simple clinical tool, but for research protocols, we suggest using the radiographic method because of the higher level of precision required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-011-1986-8

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 171

Metadata

Authors
Chapleau, J., Canet, F., Petit, Y., Laflamme, G.-Y., & Rouleau, D. M.
Venue
Clinical Orthopaedics & Related Research
Published
2011-11
Volume
469
Issue
11
Pages
3134-3140
ISSN
0009-921X (ISSN-L)
OpenAlex
W2086194538
Cited by
171
References
18
FWCI
4.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method. https://app.cochat.ai/papers/10.1007/s11999-011-1986-8
The paper
Chapleau, J., Canet, F., Petit, Y., Laflamme, G.-Y., & Rouleau, D. M. (2011). Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-011-1986-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.