Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A universal goniometer is commonly used to measure the elbow's ROM and carrying angle; however, some authors question its poor intertester reliability. QUESTIONS/PURPOSES: We (1) assessed the validity of goniometric measurements as compared with radiographic measurements in the evaluation of ROM of the elbow and (2) determined the reliability of both. METHODS: The ROM and carrying angle of 51 healthy subjects (102 elbows) were measured using two methods: with a universal goniometer by one observer three times and on radiographs by two independent examiners. Paired t-test and Pearson's correlation were used to compare and detect the relationship between mean ROM. The maximal error was calculated according to the Bland and Altman method. RESULTS: The intraclass correlation coefficients (ICC) ranged from 0.945 to 0.973 for the goniometric measurements and from 0.980 to 0.991 for the radiographic measurements. The two methods correlated when measuring the total ROM in flexion and extension. The maximal errors of the goniometric measurement were 10.3° for extension, 7.0° for flexion, and 6.5° for carrying angle 95% of the time. We observed differences for maximum flexion, maximal extension, and carrying angle between the methods. CONCLUSION: Both measurement methods differ but they correlate. When measured with a goniometer, the elbow ROM shows a maximal error of approximately 10°. CLINICAL RELEVANCE: The goniometer is a reasonable and simple clinical tool, but for research protocols, we suggest using the radiographic method because of the higher level of precision required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311 · cited 6×
“Finally, we made a plot of the difference between UG and radiographic measurements, against the mean, to illustrate and interpret the range of differences, as recommended by Bland and Altman [3, 4] and Lee et al.”
MethodInfluentialBland, J. M., & Altman, D. G. (1990) · Computers in Biology and Medicine · doi:10.1016/0010-4825(90)90013-f · Cited by 691 · cited 6×
“Finally, we made a plot of the difference between UG and radiographic measurements, against the mean, to illustrate and interpret the range of differences, as recommended by Bland and Altman [3, 4] and Lee et al.”
MethodInfluentialNormal range of motion of joints in male subjects.
Boone, D. C., & Azen, S. P. (1979) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197961050-00017 · Cited by 674 · cited 2×
“These markers, including the lateral epicondyle of the humerus and the tip of the acromion, are potential sources of error because they do not represent the center of rotation or the long axis of the humerus [1, 5, 31].”
BackgroundGoniometric Reliability in a Clinical Setting
Rothstein, J. M., Miller, P. J., & Roettger, R. F. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1611 · Cited by 546
Statistical evaluation of agreement between two methods for measuring a quantitative variable
Lee, J., Koh, D., & Ong, C. N. (1989) · Computers in Biology and Medicine · doi:10.1016/0010-4825(89)90036-x · Cited by 473
Reliability of five methods for assessing shoulder range of motion
Hayes, K., Walton, J. R., Szomor, Z. L., & Murrell, G. A. (2001) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60274-9 · Cited by 402 · cited 1×
“When reviewing the literature, there are numerous methods for measuring ROM: visual estimation [2, 13, 32, 33], photographic [7], fluid-based [10, 24] or electrogoniometer [10, 11, 34].”
MethodGoniometric Reliability in a Clinical Setting
Riddle, D. L., Rothstein, J. M., & Lamb, R. L. (1987) · Physical Therapy · doi:10.1093/ptj/67.5.668 · Cited by 398 · cited 2×
“98 [1, 20, 26, 27] and that one examiner is acceptable regardless of his or her experience [1].”
BackgroundKinesiology of the Human Body under Normal and Pathological Conditions
(1955) · Journal of the American Medical Association · doi:10.1001/jama.1955.02960170089041 · Cited by 306
London, J. T. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163040-00003 · Cited by 261 · cited 1×
“the examiner placed and rotated the fully extended elbow to make the capitellum and trochlea appear as concentric circles to achieve a perfect lateral view of the elbow [17].”
Reliability of range-of-motion measurement in the elbow and forearm
Armstrong, A. D., MacDermid, J. C., Chinchalkar, S. J., et al. (1998) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(98)90003-9 · Cited by 237 · cited 7×
“Some authors also omit detailing the population, instruments, measurement methods, or protocol when reporting UG use, making it harder to assess reliability of the UG [1, 12].”
BackgroundResultInfluential
Cited by
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Metadata
- Authors
- Chapleau, J., Canet, F., Petit, Y., Laflamme, G.-Y., & Rouleau, D. M.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2011-11
- Volume
- 469
- Issue
- 11
- Pages
- 3134-3140
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2086194538
- Cited by
- 171
- References
- 18
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method. https://app.cochat.ai/papers/10.1007/s11999-011-1986-8
- The paper
- Chapleau, J., Canet, F., Petit, Y., Laflamme, G.-Y., & Rouleau, D. M. (2011). Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-011-1986-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.