Hydrogel-based Delivery of rhBMP-2 Improves Healing of Large Bone Defects Compared With Autograft

Open access
Krishnan, Laxminarayanan, Priddy, Lauren B., Esancy, Camden, Li, Mon-Tzu Alice, Stevens, Hazel Y., Jiang, Xi, Tran, Lisa, Rowe, David W., Guldberg, Robert E. · 2015 · Clinical Orthopaedics & Related Research
Cited by 53

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Autologous bone grafting remains the gold standard in the treatment of large bone defects but is limited by tissue availability and donor site morbidity. Recombinant human bone morphogenetic protein-2 (rhBMP-2), delivered with a collagen sponge, is clinically used to treat large bone defects and complications such as delayed healing or nonunion. For the same dose of rhBMP-2, we have shown that a hybrid nanofiber mesh-alginate (NMA-rhBMP-2) delivery system provides longer-term release and increases functional bone regeneration in critically sized rat femoral bone defects compared with a collagen sponge. However, no comparisons of healing efficiencies have been made thus far between this hybrid delivery system and the gold standard of using autograft. QUESTIONS/PURPOSES: We compared the efficacy of the NMA-rhBMP-2 hybrid delivery system to morselized autograft and hypothesized that the functional regeneration of large bone defects observed with sustained BMP delivery would be at least comparable to autograft treatment as measured by total bone volume and ex vivo mechanical properties. METHODS: Bilateral critically sized femoral bone defects in rats were treated with either live autograft or with the NMA-rhBMP-2 hybrid delivery system such that each animal received one treatment per leg. Healing was monitored by radiography and histology at 2, 4, 8, and 12 weeks. Defects were evaluated for bone formation by longitudinal micro-CT scans over 12 weeks (n = 14 per group). The bone volume, bone density, and the total new bone formed beyond 2 weeks within the defect were calculated from micro-CT reconstructions and values compared for the 2-, 4-, 8-, and 12-week scans within and across the two treatment groups. Two animals were used for bone labeling with subcutaneously injected dyes at 4, 8, and 12 weeks followed by histology at 12 weeks to identify incremental new bone formation. Functional recovery was measured by ex vivo biomechanical testing (n = 9 per group). Maximum torque and torsional stiffness calculated from torsion testing of the femurs at 12 weeks were compared between the two groups. RESULTS: The NMA-rhBMP-2 hybrid delivery system resulted in greater bone formation and improved biomechanical properties compared with autograft at 12 weeks. Comparing new bone volume within each group, the NMA-rhBMP-2-treated group had higher volume (p < 0.001) at 12 weeks (72.59 ± 18.34 mm(3)) compared with 8 weeks (54.90 ± 16.14) and 4 weeks (14.22 ± 9.59). The new bone volume was also higher at 8 weeks compared with 4 weeks (p < 0.001). The autograft group showed higher (p <0.05) new bone volume at 8 weeks (11.19 ± 8.59 mm(3)) and 12 weeks (14.64 ± 10.36) compared with 4 weeks (5.15 ± 4.90). Between groups, the NMA-rhBMP-2-treated group had higher (p < 0.001) new bone volume than the autograft group at both 8 and 12 weeks. Local mineralized matrix density in the NMA-rhBMP-2-treated group was lower than that of the autograft group at all time points (p < 0.001). Presence of nuclei within the lacunae of the autograft and early appositional bone formation seen in representative histology sections suggested that the bone grafts remained viable and were functionally engrafted within the defect. The bone label distribution from representative sections also revealed more diffuse mineralization in the defect in the NMA-rhBMP-2-treated group, whereas more localized distribution of new mineral was seen at the edges of the graft pieces in the autograft group. The NMA-rhBMP-2-treated group also revealed higher torsional stiffness (0.042 ± 0.019 versus 0.020 ± 0.022 N-m/°; p = 0.037) and higher maximum torque (0.270 ± 0.108 versus 0.125 ± 0.137 N-m; p = 0.024) compared with autograft. CONCLUSIONS: The NMA-rhBMP-2 hybrid delivery system improved bone formation and restoration of biomechanical function of rat segmental bone defects compared with autograft treatment. CLINICAL RELEVANCE: Delivery systems that allow prolonged availability of BMP may provide an effective clinical alternative to autograft treatment for repair of segmental bone defects. Future studies in a large animal model comparing mixed cortical-trabecular autograft and the NMA-rhBMP-2 hybrid delivery system are the next step toward clinical translation of this approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-015-4312-z

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 53

Metadata

Authors
Krishnan, L., Priddy, L. B., Esancy, C., Li, M.-T. A., Stevens, H. Y., Jiang, X., Tran, L., Rowe, D. W., & Guldberg, R. E.
Venue
Clinical Orthopaedics & Related Research
Published
2015-09
Volume
473
Issue
9
Pages
2885-2897
ISSN
0009-921X (ISSN-L)
OpenAlex
W1966128715
Cited by
53
References
3
FWCI
3.30
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydrogel-based Delivery of rhBMP-2 Improves Healing of Large Bone Defects Compared With Autograft. https://app.cochat.ai/papers/10.1007/s11999-015-4312-z
The paper
Krishnan, L., Priddy, L. B., Esancy, C., Li, M.-T. A., Stevens, H. Y., Jiang, X., Tran, L., Rowe, D. W., & Guldberg, R. E. (2015). Hydrogel-based Delivery of rhBMP-2 Improves Healing of Large Bone Defects Compared With Autograft. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-015-4312-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.