A Fast Method for the Segmentation of Synaptic Junctions and Mitochondria in Serial Electron Microscopic Images of the Brain
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Recent electron microscopy (EM) imaging techniques permit the automatic acquisition of a large number of serial sections from brain samples. Manual segmentation of these images is tedious, time-consuming and requires a high degree of user expertise. Therefore, there is considerable interest in developing automatic segmentation methods. However, currently available methods are computationally demanding in terms of computer time and memory usage, and to work properly many of them require image stacks to be isotropic, that is, voxels must have the same size in the X, Y and Z axes. We present a method that works with anisotropic voxels and that is computationally efficient allowing the segmentation of large image stacks. Our approach involves anisotropy-aware regularization via conditional random field inference and surface smoothing techniques to improve the segmentation and visualization. We have focused on the segmentation of mitochondria and synaptic junctions in EM stacks from the cerebral cortex, and have compared the results to those obtained by other methods. Our method is faster than other methods with similar segmentation results. Our image regularization procedure introduces high-level knowledge about the structure of labels. We have also reduced memory requirements with the introduction of energy optimization in overlapping partitions, which permits the regularization of very large image stacks. Finally, the surface smoothing step improves the appearance of three-dimensional renderings of the segmented volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondria: More Than Just a Powerhouse
McBride, H. M., Neuspiel, M., & Wasiak, S. (2006) · Current Biology · doi:10.1016/j.cub.2006.06.054 · Cited by 1,985
Serial Block-Face Scanning Electron Microscopy to Reconstruct Three-Dimensional Tissue Nanostructure
Denk, W., & Horstmann, H. (2004) · PLoS Biology · doi:10.1371/journal.pbio.0020329 · Cited by 1,644 · cited 1×
“…Microscopy (FIB/SEM) and Serial Block-Face Scanning Electron Microscopy (SBFSEM) for the study of biological tissues permits the automated acquisition of large numbers of serial sections from brain samples (see for example (Denk and Horstmann 2004; Knott et al. 2008; Merchan-Perez et al. 2009)).”
BackgroundSerial section scanning electron microscopy of adult brain tissue using focused ion beam milling
Knott, G., Marchman, H., Wall, D., & Lich, B. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3189-07.2008 · Cited by 692
Convolutional Networks Can Learn to Generate Affinity Graphs for Image Segmentation
Turaga, S. C., Murray, J. F., Jain, V., Roth, F., Helmstaedter, M., Briggman, K., Denk, W., & Seung, H. S. (2010) · Neural Computation · doi:10.1162/neco.2009.10-08-881 · Cited by 376
Merchan-Pérez, A. (2009) · Frontiers in Neuroanatomy · doi:10.3389/neuro.05.018.2009 · Cited by 191 · cited 3×
“…Microscopy (FIB/SEM) and Serial Block-Face Scanning Electron Microscopy (SBFSEM) for the study of biological tissues permits the automated acquisition of large numbers of serial sections from brain samples (see for example (Denk and Horstmann 2004; Knott et al. 2008; Merchan-Perez et al. 2009)).”
BackgroundMethod
Cited by
Whole-cell organelle segmentation in volume electron microscopy
Heinrich, L., Bennett, D., Ackerman, D., Park, W., Bogovic, J., Eckstein, N., Petruncio, A., Clements, J., Pang, S., Xu, C. S., et al. (2021) · Nature · doi:10.1038/s41586-021-03977-3 · Cited by 292
Reconstruction of neocortex: Organelles, compartments, cells, circuits, and activity
Turner, N. L., Macrina, T., Bae, J. A., Yang, R., Wilson, A. M., Schneider-Mizell, C., Lee, K., Lu, R., Wu, J., Bodor, A. L., et al. (2022) · Cell · doi:10.1016/j.cell.2022.01.023 · Cited by 206
Automated synaptic connectivity inference for volume electron microscopy
Dorkenwald, S., Schubert, P. J., Killinger, M. F., Urban, G., Mikula, S., Svara, F., & Kornfeld, J. (2017) · Nature Methods · doi:10.1038/nmeth.4206 · Cited by 132
Subcellular connectomic analyses of energy networks in striated muscle
Bleck, C. K. E., Kim, Y., Willingham, T. B., & Glancy, B. (2018) · Nature Communications · doi:10.1038/s41467-018-07676-y · Cited by 150
Chen, J., Ding, L., Viana, M. P., Lee, H., Sluezwski, M. F., Morris, B., Hendershott, M. C., Yang, R., Mueller, I. A., & Rafelski, S. M. (2018) · doi:10.1101/491035 · Cited by 99
Metadata
- Authors
- Márquez Neila, P., Baumela, L., González-Soriano, J., Rodríguez, J.-R., DeFelipe, J., & Merchán-Pérez, Á.
- Venue
- Neuroinformatics
- Published
- 2016-01-16
- Volume
- 14
- Issue
- 2
- Pages
- 235-250
- ISSN
- 1539-2791 (ISSN-L)
- 1559-0089
- OpenAlex
- W2300384250
- Cited by
- 26
- References
- 5
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fast Method for the Segmentation of Synaptic Junctions and Mitochondria in Serial Electron Microscopic Images of the Brain. https://app.cochat.ai/papers/10.1007/s12021-015-9288-z
- The paper
- Márquez Neila, P., Baumela, L., González-Soriano, J., Rodríguez, J.-R., DeFelipe, J., & Merchán-Pérez, Á. (2016). A Fast Method for the Segmentation of Synaptic Junctions and Mitochondria in Serial Electron Microscopic Images of the Brain. Neuroinformatics. https://doi.org/10.1007/s12021-015-9288-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.