Subcutaneous Injection of Drugs: Literature Review of Factors Influencing Pain Sensation at the Injection Site
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The subcutaneous administration route is widely used to administer different types of drugs given its high bioavailability and rapid onset of action. However, the sensation of pain at the injection site might reduce patient adherence. Apart from a direct effect of the drug itself, several factors can influence the sensation of pain: needle features, injection site, volume injected, injection speed, osmolality, viscosity and pH of formulation, as well as the kind of excipients employed, including buffers and preservatives. Short and thin needles, conveniently lubricated and with sharp tips, are generally used to minimize pain, although the anatomic injection site (abdomen versus thigh) also affects the sensation of pain. Large subcutaneous injection volumes are associated with pain. In this sense, the maximum volume generally accepted is around 1.5 ml, although volumes of up to 3 ml are well tolerated when injected in the abdomen. Injected volumes of up to 0.5-0.8 ml are not expected to increase substantially the pain produced by the needle insertion. Ideally, injectable products should be formulated as isotonic solutions (osmolality of about 300 mOsm/kg) and no more than 600 mOs/kg have to be used in order to prevent pain. A pH close to the physiological one is recommended to minimize pain, irritation, and tissue damage. Buffers are frequently added to parenteral formulations to optimize solubility and stability by adjusting the pH; however, their strength should be kept as low as possible to avoid pain upon injection. The data available recommend the concentration of phosphate buffer be limited to 10 mM and that the concentration of citrate buffer should be lower than 7.3 mM to avoid an increased sensation of pain. In the case of preservatives, which are required in multiple-dose preparations, m-cresol seems to be more painful than benzyl alcohol and phenol.Funding: Sandoz SA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weinblatt, M. E., Keystone, E. C., Furst, D. E., Moreland, L. W., Weisman, M. H., Birbara, C. A., Teoh, L. A., Fischkoff, S. A., & Chartash, E. K. (2003) · Arthritis & Rheumatism · doi:10.1002/art.10697 · Cited by 1,757
Hanauer, S. B., Sandborn, W. J., Rutgeerts, P., Fedorak, R. N., Lukas, M., MacIntosh, D., Panaccione, R., Wolf, D., & Pollack, P. (2006) · Gastroenterology · doi:10.1053/j.gastro.2005.11.030 · Cited by 1,715
Silicone Oil- and Agitation-Induced Aggregation of a Monoclonal Antibody in Aqueous Solution
Thirumangalathu, R., Krishnan, S., Ricci, M. S., Brems, D. N., Randolph, T. W., & Carpenter, J. F. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21719 · Cited by 294
Silicone Oil Induced Aggregation of Proteins
Jones, L. S., Kaufmann, A., & Middaugh, C. R. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20321 · Cited by 285
Gibney, M. A., Arce, C. H., Byron, K. J., & Hirsch, L. J. (2010) · Current Medical Research and Opinion · doi:10.1185/03007995.2010.481203 · Cited by 283
Subcutaneous delivery of monoclonal antibodies: How do we get there?
Viola, M., Sequeira, J., Seiça, R., Veiga, F., Serra, J., Santos, A. C., & Ribeiro, A. J. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.08.001 · Cited by 234
Pain following controlled cutaneous insertion of needles with different diameters
Arendt-Nielsen, L., Egekvist, H., & Bjerring, P. (2006) · Somatosensory & Motor Research · doi:10.1080/08990220600700925 · Cited by 195
Antimicrobial preservative use in parenteral products: Past and present
Meyer, B. K., Ni, A., Hu, B., & Shi, L. (2007) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20976 · Cited by 187
Schwarzenbach, F., Berteau, C., Santos, O. F., Wang, T., Rojas, H., & Granger, C. (2015) · Medical Devices Evidence and Research · doi:10.2147/mder.s91019 · Cited by 176
Subcutaneous Injection Volume of Biopharmaceuticals—Pushing the Boundaries
Mathaes, R., Koulov, A., Joerg, S., & Mahler, H.-C. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.05.029 · Cited by 172
Effective method for drug injection into subcutaneous tissue
Kim, H., Park, H., & Lee, S. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-10110-w · Cited by 153
Derraik, J. G. B., Rademaker, M., Cutfield, W. S., Pinto, T. E., Tregurtha, S., Faherty, A., Peart, J. M., Drury, P. L., & Hofman, P. L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086637 · Cited by 129
Tolerability of hypertonic injectables
Wang, W. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.05.069 · Cited by 123
Heise, T., Nosek, L., Dellweg, S., Zijlstra, E., Præstmark, K. A., Kildegaard, J., Nielsen, G., & Sparre, T. (2014) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12304 · Cited by 113
Pain Perception after Subcutaneous Injections of Media Containing Different Buffers
Laursen, T., Hansen, B., & Fisker, S. (2006) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/j.1742-7843.2006.pto_271.x · Cited by 107
Needle free injection technology: A complete insight
Ravi, A., Sadhna, D., Nagpaal, D., & Chawla, L. (2015) · International Journal of Pharmaceutical Investigation · doi:10.4103/2230-973x.167662 · Cited by 106
Hirsch, L., Gibney, M., Berube, J., & Manocchio, J. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600216 · Cited by 96
Impact of Injection Speed, Volume, and Site on Pain Sensation
Zijlstra, E., Jahnke, J., Fischer, A., Kapitza, C., & Forst, T. M. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817735121 · Cited by 90
Evaluation of Skin and Subcutaneous Adipose Tissue Thickness for Optimal Insulin Injection
Akkus, O. (2012) · Journal of Diabetes & Metabolism · doi:10.4172/2155-6156.1000216 · Cited by 84
Bolge, S. C., Goren, A., & Tandon, N. (2015) · Patient Preference and Adherence · doi:10.2147/ppa.s70834 · Cited by 81
Pain Assessment of Subcutaneous Injections
Jørgensen, J. T., Rømsing, J., Rasmussen, M., Møller-Sonnergaard, J., Vang, L., & Musæus, L. (1996) · Annals of Pharmacotherapy · doi:10.1177/106002809603000703 · Cited by 81
Hirsch, L., Byron, K., & Gibney, M. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0111 · Cited by 76
Challenges and recent advances in the subcutaneous delivery of insulin
Guo, X., & Wang, W. (2016) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1232247 · Cited by 67
Buffered lidocaine and bupivacaine mixture -the ideal local anesthetic solution?
Best, C. A. E., Best, A. A., Best, T. J., & Hamilton, D. A. (2015) · Plastic Surgery · doi:10.1177/229255031502300206 · Cited by 60
Sim, K. H., Hwang, M. S., Kim, S. Y., Lee, H. M., Chang, J. Y., & Lee, M. K. (2014) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2014.38.2.120 · Cited by 53
Early hypoglycaemia after accidental intramuscular injection of insulin glargine
Karges, B., Boehm, B. O., & Karges, W. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01654.x · Cited by 47
Local Tolerance of Subcutaneous Injections
Fransson, J., & Espander-Jansson, A. (1996) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.1996.tb05892.x · Cited by 46
Poulos, C. M., Kinter, E. T., Yang, J., Bridges, J. F. P., Posner, J., & Reder, A. T. (2015) · Patient · doi:10.1007/s40271-015-0136-x · Cited by 42
Liquid Growth Hormone: Preservatives and Buffers
Kappelgaard, A., Bojesen, A., Skydsgaard, K., Sjögren, I., & Laursen, T. (2004) · Hormone Research in Paediatrics · doi:10.1159/000080507 · Cited by 36
Hanås, R., Lytzen, L., & Ludvigsson, J. (2000) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2000.010305.x · Cited by 30
Ringe, J. D., & Farahmand, P. (2013) · Rheumatology International · doi:10.1007/s00296-012-2663-2 · Cited by 29
Kreugel, G., BEIJER, H. J. M., Kerstens, M. N., ter Maaten, J. C., Sluiter, W. J., & Boot, B. (2007) · European Diabetes Nursing · doi:10.1002/edn.77 · Cited by 29
Improving Patient Compliance with Biopharmaceuticals by Reducing Injection-Associated Pain
So, J. (2015) · Journal of mucopolysaccharidosis and rare disease · doi:10.19125/jmrd.2015.1.1.15 · Cited by 11
Cited by
Peppou-Chapman, S., Hong, J. K., Waterhouse, A., & Neto, C. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00036a · Cited by 373
O'Shaughnessy, J., Sousa, S., Cruz, J., Fallowfield, L., Auvinen, P., Pulido, C., Cvetanovic, A., Wilks, S., Ribeiro, L., Burotto, M., et al. (2021) · European Journal of Cancer · doi:10.1016/j.ejca.2021.03.047 · Cited by 83
“Most HCPs “(strongly) agreed” that there would be less drug wastage because of PH FDC SC being ready to use and that preparation procedures and associated time staff committed would be reduced if all IV infusions were switched to SC injections.”
BackgroundInfluentialJeon, W., Park, M., Kim, S. W., & Kim, J. (2026) · Aesthetic Plastic Surgery · doi:10.1007/s00266-025-05320-x · Cited by 1
“Usach et al. [13] reported that isotonic solutions ( & 300 mmOsm/kg) with physiological pH ( * 7.4) and low buffer strength (phosphate B 10 mM) minimize nociceptor activation.”
Influential
Metadata
- Authors
- Usach, I., Martinez, R., Festini, T., & Peris, J.-E.
- Venue
- Advances in Therapy
- Published
- 2019-10-05
- Volume
- 36
- Issue
- 11
- Pages
- 2986-2996
- ISSN
- 0741-238X (ISSN-L)
- 1865-8652
- OpenAlex
- W2977374807
- Cited by
- 358
- References
- 33
- FWCI
- 21.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.