Impact of carbohydrate restriction with and without fatty acid loading on myocardial 18F-FDG uptake during PET: A randomized controlled trial
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Low-carbohydrate (LC) and high-fat, low-carbohydrate (HFLC) dietary preparations may enhance (18)F-FDG-PET-based imaging of small, inflamed structures near the heart by suppressing myocardial FDG signal. We compared myocardial (18)F-FDG uptake in patients randomized to LC, HFLC, and unrestricted (UR) preparations prior to (18)F-FDG-PET. METHODS AND RESULTS: We randomized 63 outpatients referred for oncologic (18)F-FDG-PET to LC, HFLC, or UR dietary preparations (1:1:1 allocation) starting the evening before PET. After eating dinner according to instructions, UR and LC patients fasted until FDG injection (mean time 745 minutes for UR, 899 minutes for LC), and HFLC patients drank a fatty drink 60-70 minutes prior to FDG injection. Attenuation-corrected PET imaging was performed 60 minutes after FDG administration. Maximal myocardial standard uptake values (MyoSUV(max)) were systematically measured in axial view and compared between the three groups. Using UR patients as reference, mean MyoSUV(max) was lower in LC patients (3.3 +/- 2.7 vs 6.2 +/- 5.2, P = .03) but not in HFLC patients (5.5 +/- 4.2, P = .63). Ratios of MyoSUV(max) to liver SUV(max), calculated to control for background uptake, were not significantly different amongst the groups (1.9 +/- 2.1 LC, 2.6 +/- 2.3 HFLC, 3.6 +/- 3.5 UR). CONCLUSION: In this small randomized controlled trial using UR diet as reference, LC dietary preparation followed by extended fasting resulted in significant myocardial uptake suppression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coronary Arterial 18F-Sodium Fluoride Uptake
Dweck, M. R., Chow, M. W. L., Joshi, N. V., Williams, M. C., Jones, C., Fletcher, A. M., Richardson, H., White, A., McKillop, G., van Beek, E. J. R., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.037 · Cited by 488
Dweck, M. R., Jones, C., Joshi, N. V., Fletcher, A. M., Richardson, H., White, A., Marsden, M., Pessotto, R., Clark, J. C., Wallace, W. A., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.051052 · Cited by 337
Harris, L., Hamilton, S., Azevedo, L. B., Olajide, J., De Brún, C., Waller, G., Whittaker, V., Sharp, T., Lean, M., Hankey, C., et al. (2018) · JBI Database of Systematic Reviews and Implementation Reports · doi:10.11124/jbisrir-2016-003248 · Cited by 319
Chareonthaitawee, P., Beanlands, R. S., Chen, W., Dorbala, S., Miller, E. J., Murthy, V. L., Birnie, D. H., Chen, E. S., Cooper, L. T., Tung, R. H., et al. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.196287 · Cited by 300
Dweck, M. R., Jenkins, W. S. A., Vesey, A. T., Pringle, M. A. H., Chin, C. W. L., Malley, T. S., Cowie, W. J. A., Tsampasian, V., Richardson, H., Fletcher, A., et al. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001508 · Cited by 260
“Alternative methods have been used to reduce further this myocardial uptake, including administration of heparin(18) and a high-fat drink before scanning.(19) However, these make the practicalities of scanning more difficult and have yet to show a clear advantage over dietary restrictions.”
MethodCheng, R. K., Kittleson, M. M., Beavers, C. J., Birnie, D. H., Blankstein, R., Bravo, P. E., Gilotra, N. A., Judson, M. A., Patton, K. K., Rose-Bovino, L., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001240 · Cited by 259
Chareonthaitawee, P., Beanlands, R. S., Chen, W., Dorbala, S., Miller, E. J., Murthy, V. L., Birnie, D. H., Chen, E. S., Cooper, L. T., Tung, R. H., et al. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-0978-9 · Cited by 254
Osborne, M. T., Hulten, E. A., Murthy, V. L., Skali, H., Taqueti, V. R., Dorbala, S., DiCarli, M. F., & Blankstein, R. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0502-7 · Cited by 235
“Prescribed high-fat diets were reported to contain 20-35 g of fat.(18,19) The effect of adding a high-fat drink to this diet just prior to giving (18)F-FDG in an attempt to further augment serum fatty acid levels has also been evaluated.”
BackgroundMethodInfluentialMeta-analysis of 18F-FDG PET/CT in the diagnosis of infective endocarditis
Mahmood, M., Kendi, A. T., Ajmal, S., Farid, S., O’Horo, J. C., Chareonthaitawee, P., Baddour, L. M., & Sohail, M. R. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-1092-8 · Cited by 208
“These methods all lead to a relative decrease in myocardial glucose utilization and improved image quality.(32) Heparin induces lipolysis and leads to an increase in free fatty acid levels; however, its utility in suppressing physiologic myocardial activity in clinical settings remains unclear.”
Wang, T. K. M., Sánchez-Nadales, A., Igbinomwanhia, E., Cremer, P., Griffin, B., & Xu, B. (2020) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.120.010600 · Cited by 168
Manabe, O., Yoshinaga, K., Ohira, H., Masuda, A., Sato, T., Tsujino, I., Yamada, A., Oyama-Manabe, N., Hirata, K., Nishimura, M., et al. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-015-0226-0 · Cited by 163
“LCD also has an impact on myocardial metabolism and may contribute to reducing physiological FDG uptake.(31) Kobayashi et al reported the usefulness of LCD in suppressing myocardial Figure 3.”
BackgroundMorooka, M., Moroi, M., Uno, K., Ito, K., Wu, J., Nakagawa, T., Kubota, K., Minamimoto, R., Miyata, Y., Okasaki, M., et al. (2014) · EJNMMI Research · doi:10.1186/2191-219x-4-1 · Cited by 160
“2 in those that had an unrestricted diet and fasted 12 h [24].”
BackgroundEnhancing Cardiac PET by Motion Correction Techniques
Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J. (2017) · Current Cardiology Reports · doi:10.1007/s11886-017-0825-2 · Cited by 48
Self-citation
Metadata
- Authors
- Cheng, V. Y., Slomka, P. J., Ahlen, M., Thomson, L. E. J., Waxman, A. D., & Berman, D. S.
- Venue
- Journal of Nuclear Cardiology
- Publisher
- Elsevier BV
- Published
- 2010-04
- Volume
- 17
- Issue
- 2
- Pages
- 286-291
- ISSN
- 1071-3581 (ISSN-L)
- OpenAlex
- W2086936892
- Cited by
- 118
- References
- 0
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.