X-ray imaging methods for internal quality evaluation of agricultural produce
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davies, A., & Fennessy, P. (2001) · Digital Imaging for Photographers · doi:10.1016/b978-0-240-51590-8.50007-x · Cited by 4,371
Hubbell, J. H., & Seltzer, S. M. (1995) · doi:10.6028/nist.ir.5632 · Cited by 2,033 · cited 1×
“The attenuation coefficient is a function of photon energy (Hubbell and Seltzer 1995) and for monochromatic radiation it is constant for a material.”
BackgroundThe Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Improving quality inspection of food products by computer vision––a review
Brosnan, T., & Sun, D.-W. (2004) · Journal of Food Engineering · doi:10.1016/s0260-8774(03)00183-3 · Cited by 1,011 · cited 2×
“tion techniques such as solid state TV camera, line-scan camera, X-ray scanning, ultrasound scanning and MRI (erstwhile known as nuclear magnetic resonance – NMR imaging), CT scanning, NIR (near infrared) imaging in conjunction with image processing techniques, have presented many potential avenues for non-destructive…”
BackgroundQuality measurement of fruits and vegetables
Abbott, J. A. (1999) · Postharvest Biology and Technology · doi:10.1016/s0925-5214(98)00086-6 · Cited by 811 · cited 2×
“Techniques such as X-ray imaging, Computed Tomography (CT), Magnetic Resonance Imaging (MRI) and ultrasound have been explored for non-destructive evaluation of indicators not visible on the surface of variety of agricultural products (Gunasekaran et al. 1985; Chen and Sun 1991; Abbott 1999).”
BackgroundMethodFarkas, J. (2006) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2005.12.003 · Cited by 510 · cited 1×
“One of the major concern while using X-rays is that they can ionize and thus damage the living cells (Farkas 2006).”
BackgroundHistory and future of food irradiation
Farkas, J., & Mohácsi-Farkas, C. (2011) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2010.04.002 · Cited by 439 · cited 1×
“This property of X-rays on one hand can be used for microbial and enzymatic inactivation in foods but on the other hand poses harm to humans, if exposed to. Machine generated X-rays of up to 5 MeV kinetic energy do not induce radioactivity in the exposed food or its packaging material ( Farkas and Csilla 2011 ), hence…”
BackgroundWebb, S. (1997) · Radiography · doi:10.1016/s1078-8174(97)90040-7 · Cited by 435
Learning techniques used in computer vision for food quality evaluation: a review
Du, C., & Sun, D. (2005) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2004.11.017 · Cited by 391 · cited 1×
“Manual inspection may easily be influenced by physiological factors including subjective and inconsistent evaluation results (Du and Sun 2006).”
BackgroundBrennan, J. G., Butters, J. R., Cowell, N. D., & Lilly, A. E. V. (1990) · Medical Entomology and Zoology · Cited by 254
Charge-coupled device area x-ray detectors
Gruner, S. M., Tate, M. W., & Eikenberry, E. F. (2002) · Review of Scientific Instruments · doi:10.1063/1.1488674 · Cited by 241 · cited 1×
“Gruner et al. (2002) identified phosphors and semiconductors as two types of Xray converters.”
BackgroundThe Physics of Medical Imaging
(1988) · Institute of Physics eBooks · doi:10.1887/0852743491 · Cited by 222
Dual-Energy X-Ray Absorptiometry
Lohman, T. G., & Chen, Z. (2005) · Human Body Composition · doi:10.5040/9781492596950.ch-005 · Cited by 219
Léonard, A., Blacher, S., Nimmol, C., & Devahastin, S. (2007) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2007.07.017 · Cited by 155 · cited 3×
“Leonard et al. (2008) illustrated the use of X-ray microtomography to investigate the effect of drying temperature on microstructure of a banana.”
BackgroundInfluentialThe Biomedical Engineering Handbook: Second Edition.
Henriquez, C. S. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.sec2 · Cited by 125
Postharvest Technology of Fruits and Vegetables
Thompson, A. K. (2003) · Wiley eBooks · doi:10.1002/9780470751060.ch12 · Cited by 125
AdaBoost classifiers for pecan defect classification
Mathanker, S. K., Weckler, P. R., Bowser, T. J., Wang, N., & Maness, N. O. (2011) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2011.03.008 · Cited by 89 · cited 2×
“Mathanker et al. (2011) were able to classify defects in pecans using AdaBoost classifier with reverse water flow segmentation or twice OTSU segmentation.”
MethodX-ray Computed Tomography for Internal Quality Evaluation of Peaches
Barcelon, E. G., Tojo, S., & Watanabe, K. (1999) · Journal of Agricultural Engineering Research · doi:10.1006/jaer.1999.0409 · Cited by 69 · cited 6×
“Further, Barcelon et al. (1999b, 2000) used X-ray CT technique to analyze the internal changes associated with the ripening process of mango.”
BackgroundMethodInfluentialOkochi, T., Hoshino, Y., Fujii, H., & Mitsutani, T. (2006) · Dendrochronologia · doi:10.1016/j.dendro.2006.10.010 · Cited by 58 · cited 10×
“CT can generate two and three dimensional images from the accumulated data to study physical and physiological indicators (Sonego et al. 1995; Okochi et al. 2007 ).”
BackgroundInfluentialInvestigation of 3D geometry of bulk wheat and pea pores using X-ray computed tomography images
Neethirajan, S. R., Jayas, D. S., White, N. D. G., & Zhang, H. (2008) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2008.01.019 · Cited by 49 · cited 1×
“They further developed method to analyze pores that influenced fluid transport phenomenon inside grain bulks (Neethirajan et al. 2008).”
MethodX-ray Attenuation Coefficients using Polychromatic X-ray Imaging of Pecan Components
Kotwaliwale, N., Weckler, P. R., & Brusewitz, G. H. (2006) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2006.02.013 · Cited by 27 · cited 5×
“…et al. 2006 & 2007b; Okochi et al. 2007), window material (Diener et al. 1970; Lenker and Adrian 1971; Keagy et al. 1996; Schatzki et al. 1997; Kotwaliwale et al. 2006 & 2007b), electrode material (Schatzki et al. 1997; Kotwaliwale et al. 2006 & 2007b; Okochi et al. 2007), tube cooling system…”
BackgroundMethodInfluentialSelf-citationA beam hardening correction for X-ray microtomography
de Paiva, R. F., Lynch, J. R., Rosenberg, E., & Bisiaux, M. (1998) · NDT & E International · doi:10.1016/s0963-8695(97)00032-7 · Cited by 26 · cited 1×
“However, attenuation coefficient of a material changes with thickness when measured under polychromatic X-rays (Paiva et al. 1998).”
BackgroundMeat tenderness evaluation using dual energy X-ray absorptiometry (DEXA)
Kröger, C., Bartle, C. M., West, J. G., Purchas, R. W., & Devine, C. E. (2006) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2006.09.002 · Cited by 23 · cited 2×
“2004); to evaluate meat tenderness (Kroger et al. 2006), to classify vitreousness in durum wheat (Neethirajan et al.”
BackgroundMethodDetection of glass contamination in horticultural peat with dual-energy X-ray absorptiometry (DXA)
Ayalew, G., Holden, N. M., Grace, P. M., & Ward, S. M. (2003) · Computers and Electronics in Agriculture · doi:10.1016/s0168-1699(03)00083-8 · Cited by 13 · cited 13×
“(2000), Haff and Slaughter (2004), Ayalew et al. (2004), Karunakaran et al. (2004c, 2004d), Neethirajan et al. (2006a) and Narvankar et al. (2009), Morita et al.”
BackgroundMethodInfluentialKotwaliwale, N., Kalne, A., & Singh, K. B. (2010) · Springer eBooks · doi:10.1007/978-3-642-15796-7_5 · Cited by 10 · cited 3×
“The CT number is based on linear X-ray absorption coefficients and, in general, is expressed by brightness data in an image (Kotwaliwale et al. 2011).”
BackgroundSelf-citation
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Laboratory x-ray micro-computed tomography: a user guideline for biological samples
du Plessis, A., Broeckhoven, C., Guelpa, A., & le Roux, S. G. (2017) · GigaScience · doi:10.1093/gigascience/gix027 · Cited by 374
Seed priming in field crops: potential benefits, adoption and challenges
Farooq, M., Usman, M., Nadeem, F., Rehman, H. U., Wahid, A., Basra, S. M. A., & Siddique, K. H. M. (2019) · Crop & Pasture Science · doi:10.1071/cp18604 · Cited by 290
Comprehensive utilization of shrimp waste based on biotechnological methods: A review
Mao, X., Guo, N., Sun, J., & Xue, C. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2016.12.042 · Cited by 277
X-ray micro-computed tomography (μCT) for non-destructive characterisation of food microstructure
Schoeman, L., Williams, P., du Plessis, A., & Manley, M. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2015.10.016 · Cited by 251
Metadata
- Authors
- Kotwaliwale, N., Singh, K., Kalne, A., Jha, S. N., Seth, N., & Kar, A.
- Venue
- Journal of Food Science and Technology
- Published
- 2011-08-13
- Volume
- 51
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0022-1155 (ISSN-L)
- 0975-8402
- OpenAlex
- W2041093033
- Cited by
- 250
- References
- 25
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.