Rapidly dissolving polymeric microneedles for minimally invasive intraocular drug delivery
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
In this study, dissolving microneedles (MNs) were used to enhance ocular drug delivery of macromolecules. MNs were fabricated using polyvinylpyrrolidone (PVP) polymer of various molecular weights (MWs) containing three model molecules of increasing MW, namely fluorescein sodium and fluorescein isothiocyanate–dextrans (with MW of 70 k and 150 k Da). Arrays (3 × 3) of PVP MNs with conical shape measuring about 800 μm in height with a 300 μm base diameter, containing the model drugs, were fabricated and characterized for their fracture forces, insertion forces (in the sclera and cornea), depth of penetration (using OCT and confocal imaging), dissolution time and in vitro permeation. The average drug content of the MNs (only in MN shafts) ranged from 0.96 to 9.91 μg, and the average moisture content was below 11 %. High MW PVP produced MNs that can withstand higher forces with minimal reduction in needle height. PVP MNs showed rapid dissolution that ranged from 10 to 180 s, which was dependent upon PVP’s MW. In vitro studies showed significant enhancement of macromolecule permeation when MNs were used, across both the corneal and scleral tissues, in comparison to topically applied aqueous solutions. Confocal images showed that the macromolecules formed depots within the tissues, which led to sustained permeation. However, use of MNs did not significantly benefit the permeation of small molecules; nevertheless, MN application has the potential for drug retention within the selected ocular tissues unlike topical application for small molecules. The material used in the fabrication of the MNs was found to be biocompatible with retinal cells (i.e. ARPE-19). Overall, this study reported the design and fabrication of minimally invasive rapidly dissolving polymeric MN arrays which were able to deliver high MW molecules to the eye via the intrastromal or intrascleral route. Thus, dissolving MNs have potential applications in enhancing ocular delivery of both small and macromolecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moore, K. L., Dalley, A. F., & Agur, A. M. R. (1985) · Andalas University Repository (Andalas University) · Cited by 2,232
Dissolving microneedles for transdermal drug delivery
Lee, J. W., Park, J.-H., & Prausnitz, M. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.048 · Cited by 968 · cited 1×
“Mechanical strength of the dissolving MN arrays is widely affected by several factors including polymer type and concentration, moisture content, encapsulated drug type and concentration and preparation methods [26, 41].”
BackgroundDissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948
Antonetti, D. A., Barber, A. J., Bronson, S. K., Freeman, W. M., Gardner, T. W., Jefferson, L. S., Kester, M., Kimball, S. R., Krady, J. K., LaNoue, K. F., et al. (2006) · Diabetes · doi:10.2337/db05-1635 · Cited by 746
Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety
Donnelly, R. F., Singh, T. R. R., & Woolfson, A. D. (2010) · Drug Delivery · doi:10.3109/10717541003667798 · Cited by 708
Self-citationPermeability of cornea, sclera, and conjunctiva: A literature analysis for drug delivery to the eye
Prausnitz, M. R., & Noonan, J. S. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js9802594 · Cited by 627
Topical Ocular Drug Delivery: Recent Developments and Future Challenges
LEE, V. H. L., & ROBINSON, J. R. (1986) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.1986.2.67 · Cited by 503 · cited 1×
“ability offered by various ocular tissues [8, 9].”
Microneedles: an emerging transdermal drug delivery system
Bariya, S. H., Gohel, M. C., Mehta, T. A., & Sharma, O. P. (2012) · Journal of Pharmacy and Pharmacology · doi:10.1111/j.2042-7158.2011.01369.x · Cited by 455
Donnelly, R. F., Majithiya, R., Singh, T. R. R., Morrow, D. I. J., Garland, M. J., Demir, Y. K., Migalska, K., Ryan, E., Gillen, D., Scott, C. J., et al. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0169-8 · Cited by 417 · cited 2×
“Determination of depth of penetration in ocular tissues Further studies were also performed to visualize and measure the MNs depth of penetration in the ocular tissues using optical coherence tomography (OCT) (EX1301 OCTmicroscope, Michelson Diagnostics, Kent, UK) as described previously [28], with minor modifications.”
MethodSelf-citationMinimally Invasive Protein Delivery with Rapidly Dissolving Polymer Microneedles
Sullivan, S. P., Murthy, N., & Prausnitz, M. R. (2008) · Advanced Materials · doi:10.1002/adma.200701205 · Cited by 391 · cited 1×
“cadaver porcine skin, PVP-based dissolving MNs showed significant dissolution within 1 min, and after 5 min, the MNs were 89 % (by mass) dissolved [25].”
Background
Cited by
Current trends in polymer microneedle for transdermal drug delivery
Ahmed Saeed AL-Japairai, K., Mahmood, S., Hamed Almurisi, S., Reddy Venugopal, J., Rebhi Hilles, A., Azmana, M., & Raman, S. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119673 · Cited by 448
Microneedle array systems for long-acting drug delivery
Vora, L. K., Moffatt, K., Tekko, I. A., Paredes, A. J., Volpe-Zanutto, F., Mishra, D., Peng, K., Raj Singh Thakur, R., & Donnelly, R. F. (2021) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2020.12.006 · Cited by 270
Self-citationMicroneedles as the technique of drug delivery enhancement in diverse organs and tissues
Rzhevskiy, A. S., Singh, T. R. R., Donnelly, R. F., & Anissimov, Y. G. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.048 · Cited by 266
Self-citationOvercoming ocular drug delivery barriers through the use of physical forces
Huang, D., Chen, Y.-S., & Rupenthal, I. D. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.008 · Cited by 227
Vora, L. K., Courtenay, A. J., Tekko, I. A., Larrañeta, E., & Donnelly, R. F. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.12.184 · Cited by 195
“To date, dissolving MNs have been fabricated from various materials, such as sugars, galactose [12], carboxymethylcellulose [13], poly(vinylpyrrolidone) [14,35], poly (methyl vinyl ether-maleic acid) [15], chondroitin sulfate [16] sodium hyaluronate (HA) [17] and Poly(vinyl alcohol) [31].”
BackgroundMethodSelf-citationMultifunctional Role of Polyvinylpyrrolidone in Pharmaceutical Formulations
Luo, Y., Hong, Y., Shen, L., Wu, F., & Lin, X. (2021) · AAPS PharmSciTech · doi:10.1208/s12249-020-01909-4 · Cited by 195
Vora, L. K., Donnelly, R. F., Larrañeta, E., González-Vázquez, P., Thakur, R. R. S., & Vavia, P. R. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.10.005 · Cited by 184
“dissolving MN with PLGA NMP, as it exhibits high water solubility with good mechanical strength and is biocompatible [34,35].”
Self-citationRecent Advances in Microneedle Platforms for Transdermal Drug Delivery Technologies
Mdanda, S., Ubanako, P., Kondiah, P. P. D., Kumar, P., & Choonara, Y. E. (2021) · Polymers · doi:10.3390/polym13152405 · Cited by 159
Drug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
“The SCS microneedles are designed to fit the length of the approximate thickness of the sclera and carry the following advantages: they are simple to use, less painful, inexpensive, minimally invasive, require little training, can be used in an outpatient setting and have a better safety profile, making them the most…”
BackgroundHighly water-soluble microneedle patch for short wear time and rapid drug delivery
Wood-Yang, A. J., Sankaranarayanan, A., Freidlin, M. J., & Prausnitz, M. R. (2025) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.4c01207 · Cited by 13
Metadata
- Authors
- Thakur, R. R. S., Tekko, I. A., Al-Shammari, F., Ali, A. A., McCarthy, H., & Donnelly, R. F.
- Venue
- Drug Delivery and Translational Research
- Published
- 2016-10-05
- Volume
- 6
- Issue
- 6
- Pages
- 800-815
- ISSN
- 2190-393X (ISSN-L)
- 2190-3948
- OpenAlex
- W2531808727
- Cited by
- 217
- References
- 42
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.