Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
With the rapid growth of therapeutic monoclonal antibodies (mAbs), stringent quality control is needed to ensure clinical safety and efficacy. Monoclonal antibody primary sequence and post-translational modifications (PTM) are conventionally analyzed with labor-intensive, bottom-up tandem mass spectrometry (MS/MS), which is limited by incomplete peptide sequence coverage and introduction of artifacts during the lengthy analysis procedure. Here, we describe top-down and middle-down approaches with the advantages of fast sample preparation with minimal artifacts, ultrahigh mass accuracy, and extensive residue cleavages by use of 21 tesla FT-ICR MS/MS. The ultrahigh mass accuracy yields an RMS error of 0.2-0.4 ppm for antibody light chain, heavy chain, heavy chain Fc/2, and Fd subunits. The corresponding sequence coverages are 81%, 38%, 72%, and 65% with MS/MS RMS error ~4 ppm. Extension to a monoclonal antibody in human serum as a monoclonal gammopathy model yielded 53% sequence coverage from two nano-LC MS/MS runs. A blind analysis of five therapeutic monoclonal antibodies at clinically relevant concentrations in human serum resulted in correct identification of all five antibodies. Nano-LC 21 T FT-ICR MS/MS provides nonpareil mass resolution, mass accuracy, and sequence coverage for mAbs, and sets a benchmark for MS/MS analysis of multiple mAbs in serum. This is the first time that extensive cleavages for both variable and constant regions have been achieved for mAbs in a human serum background. Graphical Abstract ᅟ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1182-2 · Cited by 278
Self-citationProSight Lite: Graphical software to analyze top‐down mass spectrometry data
Fellers, R. T., Greer, J. B., Early, B. P., Yu, X., LeDuc, R. D., Kelleher, N. L., & Thomas, P. M. (2015) · PROTEOMICS · doi:10.1002/pmic.201400313 · Cited by 247
Research works printed but not linked: 41
- 10.1038/nri2747 · DOI · Paper page
- 10.4161/19420862.2015.989042 · DOI · Paper page
- 10.1038/nrc3236 · DOI · Paper page
- 10.1038/nri2761 · DOI · Paper page
- 10.1016/j.bmcl.2014.10.021 · DOI · Paper page
- 10.1016/j.coi.2016.03.005 · DOI
- 10.3109/10408363.2013.838206 · DOI
- 10.1021/ac3032355 · DOI · Paper page
- 10.1002/pmic.201300366 · DOI
- 10.1021/ac502766n · DOI
- 10.1021/acs.analchem.5b02739 · DOI
- 10.1074/mcp.O115.056721 · DOI · Paper page
- 10.1021/ac502378e · DOI · Paper page
- 10.1002/rcm.4464 · DOI
- 10.1002/mas.20190 · DOI · Paper page
- 10.1021/ac303525n · DOI · Paper page
- 10.1074/mcp.M112.019620 · DOI · Paper page
- 10.1021/ac503158g · DOI
- 10.1016/j.jasms.2009.03.020 · DOI · Paper page
- 10.1021/ac070483q · DOI
- 10.1021/ac4036857 · DOI · Paper page
- 10.1021/acs.analchem.6b00302 · DOI · Paper page
- 10.1039/C6AN00071A · DOI · Paper page
- 10.1016/S1387-3806(99)00226-2 · DOI · Paper page
- 10.1021/ac00278a027 · DOI · Paper page
- 10.1158/1078-0432.CCR-12-2922 · DOI
- 10.1111/ijlh.12504 · DOI
- 10.1002/1097-0142(197509)36:3<842::AID-CNCR2820360303>3.0.CO;2-U · DOI · Paper page
- 10.1128/CVI.13.2.277-280.2006 · DOI
- 10.1021/pr400985k · DOI · Paper page
- 10.1111/bjh.13003 · DOI
- 10.1016/j.jneuroim.2015.09.011 · DOI
- 10.1002/rcm.7314 · doi:10.1002/rcm.7314
- 10.1016/j.ymeth.2015.04.020 · DOI
- 10.1515/cclm-2015-0917 · DOI
- Kohlhagen, M.C., Barnidge, D.R., Mills, J.R., Stoner, J., Gurtner, K.M., Liptac, A.M., Lofgren, D.I., Vanderboom, P.M., Diepenzieri, A., Katzmann J.A., Willrich, M.A., Snyder, M.R., Murray, D.L.: Screening method for M-proteins in serum using nanobody enrichment coupled to MALDI-TOF mass spectrometry. Clin. Chem. 62, 1345–1352 (2016) · DOI
- 10.1515/cclm-2015-0994 · DOI
- 10.1021/acs.analchem.6b00544 · DOI
- Mills, J.R., Kohlhagen, M.C., Dasari, S., Vanderboom, P.M., Kyle, R.A., Katzmann, J.A., Willrich, M.A., Barnidge, D.R., Dispenzieri, A., Murray, D.L.: Comprehensive assessment of M-proteins using nanobody enrichment coupled to MALDI-TOF mass spectrometry. Clin. Chem. 62, 1334–1344 (2016) · DOI · Paper page
- 10.1021/pr5005967 · doi:10.1021/pr5005967
- 10.4161/mabs.28762 · DOI · Paper page
Cited by
Ion Activation Methods for Peptides and Proteins
Brodbelt, J. S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04563 · Cited by 248
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Fornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150
Ion Activation Methods for Peptides and Proteins
Macias, L. A., Santos, I. C., & Brodbelt, J. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04859 · Cited by 107
Jin, Y., Lin, Z., Xu, Q., Fu, C., Zhang, Z., Zhang, Q., Pritts, W. A., & Ge, Y. (2019) · mAbs · doi:10.1080/19420862.2018.1525253 · Cited by 68
Metadata
- Authors
- He, L., Anderson, L. C., Barnidge, D. R., Murray, D. L., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-28
- Volume
- 28
- Issue
- 5
- Pages
- 827-838
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2594148209
- Cited by
- 55
- References
- 4
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Update notices
- correction (2017-03-23)
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS. https://app.cochat.ai/papers/10.1007/s13361-017-1602-6
- The paper
- He, L., Anderson, L. C., Barnidge, D. R., Murray, D. L., Hendrickson, C. L., & Marshall, A. G. (2017). Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-017-1602-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.