Abstract

In this study, a novel green hydrophobic deep eutectic solvent (DES) composed of oleic acid (OLC) and betaine hydrochloride (BET) was synthesized and applied for the extraction of Sudan IV dye from natural water and food samples using ultrasonic-assisted dispersive liquid-phase microextraction (UA-DLPME). In this DES system, OLC acted as the hydrogen bond donor (HBD), while BET served as the hydrogen bond acceptor (HBA). Key analytical parameters, including pH, DES molar ratio, sonication and centrifugation times, and initial and final sample volumes, were studied and optimized. The DES-UA-DLPME method exhibited a rapid and efficient extraction process, achieving equilibrium within 1 min at room temperature. The method demonstrated excellent analytical performance with a limit of detection (LOD) and limit of quantification (LOQ) of 0.75 and 2.48 µg kg −1 for food samples and 0.914 and 3.047 µg L −1 for water samples, respectively. The method’s preconcentration factor (PF) and enrichment factor (EF) were 40 and 35.8, respectively, with an acceptable analytical recovery (AR) of 87–104% across various matrices. The linear dynamic range (LDR) was 0.1–600 µg L −1 with a correlation coefficient ( R 2 ) of 0.995. The precision of the method, expressed as relative standard deviation (RSD), was 4.9% ( n = 6). Matrix effects were also studied and found to be negligible for the tested natural water and food samples in the recovery range of 87–106%. This DES-UA-DLPME approach offers a green, rapid, and highly effective method for the determination of Sudan IV dye in complex matrices.

Overview

CoChat Summary

TL;DR

A novel hydrophobic deep eutectic solvent (DES) made from oleic acid (HBD) and betaine hydrochloride (HBA) was synthesized and applied in ultrasonic-assisted dispersive liquid-phase microextraction (UA-DLPME) for Sudan IV in water and food samples. The method achieved rapid extraction within 1 min at room temperature, with LOD/LOQ of 0.75/2.48 µg kg⁻¹ for food and 0.914/3.047 µg L⁻¹ for water, recovery of 87–104%, PF 40, and EF 35.8.

Key findings

  • Optimal DES-UA-DLPME conditions were pH 6, BET:OLC molar ratio 1:1, 200 µL DES, 1 min sonication, 1 min centrifugation, and room temperature; extraction reached equilibrium within 1 min.
  • Analytical performance: LOD/LOQ were 0.752/2.48 µg kg⁻¹ for food and 0.914/3.047 µg L⁻¹ for water; LDR was 0.1–600 µg L⁻¹ with R² = 0.995; RSD was 4.9% (n = 6); PF was 40 and EF was 35.8; analytical recovery was 87–104%.
  • Real-sample recoveries were 87–103% for water and 89–104% for food, with RSD 1.1–6% in standard-addition tests; Sudan IV was detected in curry (89 ± 12 µg L⁻¹), sweet paprika (1254 ± 78 µg L⁻¹), chili pepper (738 ± 33 µg L⁻¹), hot sauce (353 ± 23 µg L⁻¹), and tomato paste (94 ± 12 µg L⁻¹), but not in turmeric, sumac, ketchup, or tomato sauce.
  • Greenness assessment gave SPMS greenness >70% and AGREEprep score 0.67, with 10 of 12 principles classified green and two yellow (scores 0.43 and 0.5) due to hazardous material use and automation level; interference tests with ions, anions, and other dyes gave recoveries of 87–106%.

Methods

  • DES preparation: BET and OLC were mixed at molar ratios 1:1, 1:1.5, 1:2, 1.5:1, and 2:1; heated at 80 °C initially, with temperature optimization from 50–90 °C identifying 65 °C as optimal; DES and DES–Sudan IV were characterized by FTIR and ¹H NMR.
  • UA-DLPME procedure: 40 mL sample solution containing 2 mL acetate buffer (pH 6), 500 µL Sudan IV (10 mg L⁻¹), and 200 µL DES was sonicated for 1 min at 25 °C, centrifuged for 1 min, and the organic layer was dissolved in ethanol to 1 mL; absorbance was measured by UV-Vis at 520 nm.
  • Samples and analysis: tap water from Kayseri, Türkiye, and food samples from a local market; food samples (0.5 g) were dissolved in 10 mL ethanol, sonicated 30 min, diluted with 30 mL water, sonicated 1 h, centrifuged 10 min, then subjected to DES-UA-DLPME; standard-addition recovery tests and interference studies were performed.

Limitations

  • The paper states that more research is needed to fully understand the chemistry behind the pH and DES ratio effects, and that additional research, further optimization, and validation experiments are needed to explore causes of measurement variations and improve broader use.
  • The paper reports significant variability in some real samples, e.g., curry RSD 13.2% and tomato paste RSD 12.4%, while other samples had relatively low RSD values; it notes possible causes of variance but does not fully resolve them.
  • Evident from the text: the method was validated only for Sudan IV, not for other Sudan dyes; also, chemical and instrumentation details are stated to be in Supporting Information rather than in the provided text.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s13738-025-03212-0

Cites

67 of 67 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 11 Not checked · 102 Own results and interpretations

58 more claims

Create a free account to see all 114 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 45
  • Probably not a substantial claim. 10
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

5 of 12 · the rest aren’t loaded

7 more findings

Create a free account to see every finding of this check.

See all findings — free account

Citations

Cites

Show all 67 references

Research works printed but not linked: 1

  1. M. Stiborová, H. Martinek, P. Hodek, E. Frei, Cancer Res. 62, 5678 (2002)

Cited by

Metadata

Authors
Soylak, M., Çoban, A. N., & Ahmed, H. E. H.
Affiliations
  • Turkish Academy of Sciences (TR)
  • Erciyes University (TR)
Corresponding author
Soylak, Mustafa
Venue
Journal of the Iranian Chemical Society
Published
2025-04-15
Volume
22
Issue
5
Pages
1125-1137
ISSN
  • 1735-207X (ISSN-L)
  • 1735-2428
OpenAlex
W4409480594
Cited by
9
References
67
Citations by year
2026: 4 · 2025: 5
FWCI
3.38
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of the Iranian Chemical Society (publishedVersion, cc-by)
  • Erciyes University - AVESIS (submittedVersion)
Funders
Erciyes University
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Dye analysis and toxicity
Keywords
deep eutectic solvents, oleic acid, betaine hydrochloride, Sudan IV, liquid-phase microextraction, food dye determination, water samples, green extraction, matrix effects, preconcentration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel deep eutectic solvent based on oleic acid and betaine hydrochloride for liquid-phase microextraction of Sudan IV from water and food samples. https://app.cochat.ai/papers/10.1007/s13738-025-03212-0
The paper
Soylak, M., Çoban, A. N., & Ahmed, H. E. H. (2025). A novel deep eutectic solvent based on oleic acid and betaine hydrochloride for liquid-phase microextraction of Sudan IV from water and food samples. Journal of the Iranian Chemical Society. https://doi.org/10.1007/s13738-025-03212-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.