The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Updates on the research and development of absorbable metals for biomedical applications
Open accessAbstract
Absorbable metals, metals that corrode in physiological environment, constitute a new class of biomaterials intended for temporary medical implant applications. The introduction of these metals has shifted the established paradigm of metal implants from preventing corrosion to its direct application. Interest toward absorbable metals has been growing in the past decade. This is proved by the rapid increase in scientific publication, progressive development of standards, and launching the first commercial products. Iron, magnesium, zinc, and their alloys are the current three absorbable metals families. Magnesium-based metals are the most progressing family with a large data set obtained from both basic and translational research. Iron-based metals are still facing a major challenge of low in vivo corrosion rate despite the significant efforts that have been put to overcome its weakness. Zinc-based metals are the new alternative absorbable metals with moderate corrosion rates that fall between those of iron and magnesium. This manuscript provides a brief review on the latest progress in the research and development of absorbable metals, the most important findings, the remaining challenges, and the perspective on the future direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
Cited by
Biodegradable materials for bone defect repair
Wei, S., Ma, J.-X., Xu, L., Gu, X.-S., & Ma, X.-L. (2020) · Military Medical Research · doi:10.1186/s40779-020-00280-6 · Cited by 406
Additive manufacturing of biodegradable metals: Current research status and future perspectives
Qin, Y., Wen, P., Guo, H., Xia, D., Zheng, Y., Jauer, L., Poprawe, R., Voshage, M., & Schleifenbaum, J. H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.046 · Cited by 303
Additively manufactured biodegradable porous iron
Li, Y., Jahr, H., Lietaert, K., Pavanram, P., Yilmaz, A., Fockaert, L. I., Leeflang, M. A., Pouran, B., Gonzalez-Garcia, Y., Weinans, H., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.07.011 · Cited by 299
Biodegradable magnesium‐based biomaterials: An overview of challenges and opportunities
Amukarimi, S., & Mozafari, M. (2021) · MedComm · doi:10.1002/mco2.59 · Cited by 258
Martinez, D. C., Borkam-Schuster, A., Helmholz, H., Dobkowska, A., Luthringer-Feyerabend, B., Płociński, T., Willumeit-Römer, R., & Święszkowski, W. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.08.015 · Cited by 21
Metadata
- Authors
- Hermawan, H.
- Venue
- Progress in Biomaterials
- Published
- 2018-05-22
- Volume
- 7
- Issue
- 2
- Pages
- 93-110
- ISSN
- 2194-0509 (ISSN-L)
- 2194-0517
- OpenAlex
- W2803136671
- Cited by
- 260
- References
- 1
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Updates on the research and development of absorbable metals for biomedical applications. https://app.cochat.ai/papers/10.1007/s40204-018-0091-4
- The paper
- Hermawan, H. (2018). Updates on the research and development of absorbable metals for biomedical applications. Progress in Biomaterials. https://doi.org/10.1007/s40204-018-0091-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.