Cited by 30Electronic Health Records SystemsPharmaceutical Practices and Patient OutcomesPatient Safety and Medication Errors

Comparison of Medication Alerts from Two Commercial Applications in the USA

Open access
Shah, Sonam N., Seger, Diane L., Fiskio, Julie M., Horn, John R., Bates, David W.·2021·Drug Safety

Abstract

INTRODUCTION: Medication organizations across the USA have adopted electronic health records, and one of the most anticipated benefits of these was improved medication safety, but alert fatigue has been a major issue. OBJECTIVE: We compared the appropriateness of medication-related clinical decision support alerts triggered by two commercial applications: EPIC and Seegnal's platform. METHODS: This was a retrospective comparison of two commercial applications. We provided Seegnal with deidentified inpatient, outpatient, and inpatient genetic electronic medical record (EMR)-extracted datasets for 657, 2731, and 413 patients, respectively. Seegnal then provided the alerts that would have triggered, which we compared with those triggered by EPIC in clinical care. A random sample of the alerts triggered were reviewed for appropriateness, and the positive predictive value (PPV) and negative predictive value (NPV) were calculated. We also reviewed all the inpatient and outpatient charts for patients within our cohort who were receiving ten or more concomitant medications with alerts we found to be appropriate to assess whether any adverse events had occurred and whether Seegnal's platform could have prevented them. RESULTS: Results from EPIC and the Seegnal platform were compared based on alert load, PPV, NPV, and potential adverse events. Overall, compared with EPIC, the Seegnal platform triggered fewer alerts in the inpatient (1697 vs. 27,540), outpatient (2341 vs. 35,134), and inpatient genetic (1493 vs. 20,975) cohorts. The Seegnal platform had higher specificity in the inpatient (99 vs. 0.3%; p < 0.0001), outpatient (99 vs. 0.3%; p < 0.0001), and inpatient genetic (97.9 vs. 1.2%; p < 0.0001) groups and higher sensitivity in the inpatient (100 vs. 68.8%; p < 0.0001) and outpatient (88.6 vs.78.3%; p < 0.0001) groups but not in the inpatient genetic cohort (81 vs. 78.5%; p = 0.11). We identified 16 adverse events that occurred in the inpatient setting, 11 (69%) of which potentially could have been prevented with the Seegnal platform. CONCLUSIONS: Overall, the Seegnal platform triggered 94% fewer alerts than EPIC in the inpatient setting and 93% fewer in the outpatient setting, with much higher sensitivity and specificity. This application could substantially reduce alert fatigue and improve medication safety at the same time.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s40264-021-01048-0

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Different studies have shown a substantial reduction in DDI alert burden by applying patient and context-specific factors.

    “Different studies have shown a substantial reduction in DDI alert burden by applying patient and context-specific factors [14–18].”

    From Overall performance of a drug–drug interaction clinical decision support system: quantitative evaluation and end-user survey (2022) · cites this paper as [16]

    The Conclusion (page unavailable) attributes a projected nearly twentyfold reduction in overall medication-alert load to real-time use of patient- and medication-specific factors. The Methods, Technology Assessed section includes drug–drug interactions among the alert types, but the reported reduction is not specific to DDI alerts; the paper also says real-time alert-load reduction still needs testing. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Shah et al. compared two commercial CDSSs and showed a 94% reduction in alert burden, with much higher sensitivity and specificity.

    “Shah et al. compared two commercial CDSSs and showed a 94% reduction in alert burden, with much higher sensitivity and specificity [16].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 22

  1. [1]Institute of Medicine Evidence-based medicine and the changing nature of health care: 2007 IOM annual meeting summary 2008 Washington, DC National Academies Press 21391346
  2. [2]Beijer HJ de Blaey CJ Hospitalizations caused by adverse drug reactions (ADR): a meta-analysis of observational studies Pharm World Sci 2002 24 2 46 54 10.1023/A:1015570104121 12061133 · DOI
  3. [3]Lazarou J Pomeranz BH Corey PN Incidence of adverse drug reactions in hospitalized patients: a meta-analysis of prospective studies JAMA 1998 279 1200 1205 10.1001/jama.279.15.1200 9555760 · DOI · Paper page
  4. [4]Budnitz DS Pollock DA Weidenbach KN National surveillance of emergency department visits for outpatient adverse drug events JAMA 2006 296 15 1858 1866 10.1001/jama.296.15.1858 17047216 · DOI
  5. [5]Makary MA Daniel M Medical error- the third leading cause of death in the US BMJ 2016 353 i2139 10.1136/bmj.i2139 27143499 · DOI · Paper page
  6. [6]Corsonello A Pedone C Corica F Concealed renal insufficiency and adverse drug reactions in elderly hospitalized patients Arch Intern Med. 2005 165 790 795 10.1001/archinte.165.7.790 15824299 · DOI
  7. [7]Bates DW Leape LL Cullen DJ Effect of computerized physician order entry and a team intervention on prevention of serious medication errors JAMA 1998 280 1311 1316 10.1001/jama.280.15.1311 9794308 · DOI · Paper page
  8. [8]Kaushal R Shojania KG Bates DW Effects of computerized physician order entry and clinical decision support systems on medication safety: a systematic review Arch Intern Med 2003 163 12 1409 1416 10.1001/archinte.163.12.1409 12824090 · DOI · Paper page
  9. [9]Nuckols TK Smith-Spangler C Morton SC The effectiveness of computerized order entry at reducing preventable adverse drug events and medication errors in hospital settings: a systematic review and meta-analysis Syst Rev 2014 3 56 10.1186/2046-4053-3-56 24894078 PMC4096499 · DOI · Paper page
  10. [10]Shamliyan TA Duval S Du J Kane RL Just what the doctor ordered. Review of the evidence of the impact of computerized physician order entry system on medication errors Health Serv Res 2007 43 32 35 10.1111/j.1475-6773.2007.00751.x PMC2323150 18211517 · DOI
  11. [11]Wolfstadt JI Gurwitz JH Field TS The effect of computerized physician order entry with clinical decision support on the rates of adverse drug events: a systematic review J Gen Intern Med 2008 23 4 451 458 10.1007/s11606-008-0504-5 18373144 PMC2359507 · DOI
  12. [12]Bates DW Teich JM Lee J The impact of computerized physician order entry on medication error prevention J Am Med Inform Assoc. 1999 6 313 321 10.1136/jamia.1999.00660313 10428004 PMC61372 · DOI · Paper page
  13. [13]Lin CP Payne TH Nichol P Hoey PJ Anderson CL Gennari JH Evaluating clinical decision support systems: monitoring CPOE order check override rates in the Department of Veterans Affairs’ Computerized Patient Record System J Am Med Inform Assoc. 2008 15 620 626 10.1197/jamia.M2453 18579840 PMC2528033 · DOI · Paper page
  14. [14]Nanji KC Slight SP Seger DL Overrides of medication-related clinical decision support alerts in inpatients J Am Med Inform Assoc. 2018 25 5 476 481 10.1093/jamia/ocx15 29092059 PMC7646870 · DOI
  15. [16]Kuperman GJ Bobb A Payne TH Medication-related clinical decision support in computerized provider order entry systems: a review J Am Med Inform Assoc. 2007 14 01 29 40 10.1197/jamia.M2170 17068355 PMC2215064 · DOI · Paper page
  16. [17]Payne TH Nichol WP Hoey P Savarino J Characteristics and override rates of order checks in a practitioner order entry system Proc AMIA Symp. 2002 2002 602 606 PMC2244252 12463894
  17. [19]Weingart SN Toth M Sands DZ Aronson MD Davis RB Phillips RS Physicians' decisions to override computerized drug alerts in primary care Arch Intern Med. 2003 163 21 2625 2631 10.1001/archinte.163.21.2625 14638563 · DOI · Paper page
  18. [20]Hsieh TC Kuperman GJ Jaggi T Characteristics and consequences of drug allergy alert overrides in a computerized physician order entry system J Am Med Inform Assoc. 2004 11 06 482 491 10.1197/jamia.M1556 15298998 PMC524628 · DOI · Paper page
  19. [21]Wong A Amato MG Seger DL Evaluation of medication-related clinical decision support alert overrides in the intensive care unit J Crit Care 2017 39 156 161 10.1016/j.jcrc.2017.02.027 28259059 · DOI
  20. [23]Bates DW Leape LL Cullen DJ Effect of computerized physician order entry and a team intervention on prevention of serious medication errors JAMA 1998 280 15 1311 1316 10.1001/jama.280.15.1311 9794308 · DOI · Paper page
  21. [24]Ash JS Sitting DF Campbell EM Guappone KP Dykstra RH Some unintended consequences of clinical decision support systems AMIA Annu Symp Proc. 2007 2008 26 30 PMC2813668 18693791
  22. [26]Coleman JJ, van der Sijs H, Haefeli WE, et al. On the alert: future priorities for alerts in clinical decision support for computerized physician order entry identified from a European workshop [published correction appears in BMC Med Inform Decis Mak. 2013;13:122]. BMC Med Inform Decis Mak. 2013;13:111. 10.1186/1472-6947-13-111 PMC3850158 24083548 · DOI

Cited by

Sorted by citations

Authors
Shah, S. N., Seger, D. L., Fiskio, J. M., Horn, J. R., & Bates, D. W.
Affiliations
  • Brigham and Women's Hospital (US)
  • Mass General Brigham (US)
  • University of Washington (US)
Corresponding author
Shah, Sonam N.
Venue
Drug Safety
Published
2021-02-22
Volume
44
Issue
6
Pages
661-668
ISSN
  • 0114-5916 (ISSN-L)
  • 1179-1942
OpenAlex
W3129492961
Cited by
30
References
3
Citations by year
2026: 1 · 2025: 3 · 2024: 6 · 2023: 9 · 2022: 9 · 2021: 2
FWCI
5.67
Type
journal article
Language
en
Open access
Locations
  • Drug Safety (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
Seegnal
Topics
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
  • Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
Keywords
medication alerts, clinical decision support, alarm fatigue, drug safety, epic, electronic health records, adverse drug reactions, polypharmacy, predictive value, inpatient and outpatient care, medication reconciliation
MeSH terms
Humans, Medication Errors, Retrospective Studies, Decision Support Systems, Clinical, Medical Order Entry Systems, Electronic Health Records

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review