Surface-functionalized design of blood-contacting biomaterials for preventing coagulation and promoting hemostasis
Open accessThe DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
Abstract
The anticoagulation and hemostatic properties of blood-contacting materials are opposite lines of research, but their realization mechanisms are inspired by each other. Contact between blood and implantable biomaterials is a classic problem in tribological research, as both antithrombotic and hemostatic materials are closely associated with this problem. Thrombus formation on the surfaces of blood-contacting biomedical devices can detrimentally affect their performance and patient life, so specific surface functionalization is required. Currently, intensive research has focused on the development of super-lubricated or super-hydrophobic coatings, as well as coatings that deliver antithrombotic drugs. In addition, hemostatic biomaterials with porous structures, biochemical substances, and strongly adhesive hydrogels can be used to achieve rapid and effective hemostasis via physical or biochemical mechanisms. This article reviews methods of preparing anticoagulant coatings on material surfaces and the current status of rapid hemostatic materials. It also summarizes fundamental concepts for the design and synthesis of anticoagulant and hemostatic materials by discussing thrombosis and hemostasis mechanisms in biomedical devices and normal organisms. Because there are relatively few reports reviewing the progress in surface-functionalized design for anticoagulation and hemostasis, it is anticipated that this review can provide a useful summary of the applications of both bio-adhesion and bio-lubrication techniques in the field of biomedical engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dry double-sided tape for adhesion of wet tissues and devices
Yuk, H., Varela, C. E., Nabzdyk, C. S., Mao, X., Padera, R. F., Roche, E. T., & Zhao, X. (2019) · Nature · doi:10.1038/s41586-019-1710-5 · Cited by 1,471 · cited 3×
“[113] Yuk H, Varela C E, Nabzdyk C S, Mao X, Padera R F,”
BackgroundMethodInfluentialA strongly adhesive hemostatic hydrogel for the repair of arterial and heart bleeds
Hong, Y., Zhou, F., Hua, Y., Zhang, X., Ni, C., Pan, D., Zhang, Y., Jiang, D., Yang, L., Lin, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10004-7 · Cited by 836 · cited 3×
“[104] Hong Y, Zhou F, Hua Y, Zhang X, Ni C, Pan D, Zhang Y,”
BackgroundMethodInfluentialMultifunctional Photoactive Hydrogels for Wound Healing Acceleration
Maleki, A., He, J., Bochani, S., Nosrati, V., Shahbazi, M.-A., & Guo, B. (2021) · ACS Nano · doi:10.1021/acsnano.1c08334 · Cited by 568 · cited 2×
“Friction 10: 54–67 (2022) [95] Maleki A, He J, Bochani S, Nosrati V, Shahbazi M-A, Guo”
BackgroundKlein, J. (2013) · Friction · doi:10.1007/s40544-013-0001-7 · Cited by 567 · cited 2×
“Friction 10: 232–246 (2022) [49] Klein J.”
BackgroundMedical device‐induced thrombosis: what causes it and how can we prevent it?
Jaffer, I. H., Fredenburgh, J. C., Hirsh, J., & Weitz, J. I. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12961 · Cited by 557 · cited 11×
“Additionally, it was also demonstrated that consistent results could be obtained with metal (GCr15 steel) or ceramic (SiN) balls for upper www.Springer.com/journal/40544 | Friction specimens, whereas the results fluctuated slightly and were unstable when using Teflon balls.”
BackgroundInfluentialPlatelets at work in primary hemostasis
Broos, K., Feys, H. B., De Meyer, S. F., Vanhoorelbeke, K., & Deckmyn, H. (2011) · Blood Reviews · doi:10.1016/j.blre.2011.03.002 · Cited by 502 · cited 2×
“[57] Broos K, Feys H B, De Meyer S F, Vanhoorelbeke K, Deckmyn H.”
BackgroundEndothelial responses to shear stress in atherosclerosis: a novel role for developmental genes
Souilhol, C., Serbanovic-Canic, J., Fragiadaki, M., Chico, T. J., Ridger, V., Roddie, H., & Evans, P. C. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0239-5 · Cited by 480 · cited 2×
“, shear magnitude and directionality) and control vascular tension via converting perceptual information into biochemical responses [20, 21].”
BackgroundPolymeric hydrogel systems as emerging biomaterial platforms to enable hemostasis and wound healing
Pourshahrestani, S., Zeimaran, E., Kadri, N. A., Mutlu, N., & Boccaccini, A. R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000905 · Cited by 448 · cited 2×
“[99] Pourshahrestani S, Zeimaran E, Kadri N A, Mutlu N,”
BackgroundDu, X., Wu, L., Yan, H., Jiang, Z., Li, S., Li, W., Bai, Y., Wang, H., Cheng, Z., Kong, D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24972-2 · Cited by 362 · cited 3×
“(e) A chitosan-based hemostatic sponge prepared using 3D printing technology [89].”
BackgroundMethodInfluentialEndothelial cells and coagulation
Neubauer, K., & Zieger, B. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03471-2 · Cited by 351 · cited 1×
“In human blood, the endothelium maintains a dynamic balance between coagulation and bleeding, thereby ensuring normal blood flow [4].”
Background
Cited by
Friction behavior of biodegradable electrospun polyester nanofibrous membranes
Wang, Y., Zhai, W., Li, J., Liu, H., Li, C., & Li, J. (2023) · Tribology International · doi:10.1016/j.triboint.2023.108891 · Cited by 199
Self-citationHeidari, A., Javaheri, D., Toumaj, S., Navimipour, N. J., Rezaei, M., & Unal, M. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2023.102572 · Cited by 138
Roshani, M., Rezaian-Isfahni, A., Lotfalizadeh, M. H., Khassafi, N., Abadi, M. H. J. N., & Nejati, M. (2023) · Cancer Cell International · doi:10.1186/s12935-023-03115-1 · Cited by 84
Sharma, S., Bhattacharya, S., Joshi, K., & Singh, S. (2023) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-023-05331-8 · Cited by 13
Metadata
- Authors
- Wang, Y., Zhai, W., Cheng, S., Li, J., & Zhang, H.
- Venue
- Friction
- Publisher
- Tsinghua University Press
- Published
- 2023-02-11
- Volume
- 11
- Issue
- 8
- Pages
- 1371-1394
- ISSN
- 2223-7690 (ISSN-L)
- 2223-7704
- OpenAlex
- W4320033553
- Cited by
- 216
- References
- 130
- FWCI
- 14.54
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.