Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Flexible Tactile Electronic Skin Sensor with 3D Force Detection Based on Porous CNTs/PDMS Nanocomposites

Open access
Sun, Xuguang, Sun, Jianhai, Li, Tong, Zheng, Shuaikang, Wang, Chunkai, Tan, Wenshuo, Zhang, Jingong, Liu, Chang, Ma, Tianjun, Qi, Zhimei, Liu, Chunxiu, Xue, Ning·2019·Nano-Micro Letters

Abstract

Flexible tactile sensors have broad applications in human physiological monitoring, robotic operation and human–machine interaction. However, the research of wearable and flexible tactile sensors with high sensitivity, wide sensing range and ability to detect three-dimensional (3D) force is still very challenging. Herein, a flexible tactile electronic skin sensor based on carbon nanotubes (CNTs)/polydimethylsiloxane (PDMS) nanocomposites is presented for 3D contact force detection. The 3D forces were acquired from combination of four specially designed cells in a sensing element. Contributed from the double-sided rough porous structure and specific surface morphology of nanocomposites, the piezoresistive sensor possesses high sensitivity of 12.1 kPa−1 within the range of 600 Pa and 0.68 kPa−1 in the regime exceeding 1 kPa for normal pressure, as well as 59.9 N−1 in the scope of < 0.05 N and > 2.3 N−1 in the region of < 0.6 N for tangential force with ultra-low response time of 3.1 ms. In addition, multi-functional detection in human body monitoring was employed with single sensing cell and the sensor array was integrated into a robotic arm for objects grasping control, indicating the capacities in intelligent robot applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s40820-019-0288-7

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 229

Metadata

Authors
Sun, X., Sun, J., Li, T., Zheng, S., Wang, C., Tan, W., Zhang, J., Liu, C., Ma, T., Qi, Z., Liu, C., & Xue, N.
Venue
Nano-Micro Letters
Published
2019-07-16
Volume
11
Issue
1
Pages
57-57
ISSN
  • 2150-5551 (ISSN-L)
  • 2311-6706
OpenAlex
W2956286142
Cited by
229
References
7
FWCI
8.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Tactile Electronic Skin Sensor with 3D Force Detection Based on Porous CNTs/PDMS Nanocomposites. https://app.cochat.ai/papers/10.1007/s40820-019-0288-7
The paper
Sun, X., Sun, J., Li, T., Zheng, S., Wang, C., Tan, W., Zhang, J., Liu, C., Ma, T., Qi, Z., Liu, C., & Xue, N. (2019). Flexible Tactile Electronic Skin Sensor with 3D Force Detection Based on Porous CNTs/PDMS Nanocomposites. Nano-Micro Letters. https://doi.org/10.1007/s40820-019-0288-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.