High-Porosity Foam-Based Iontronic Pressure Sensor with Superhigh Sensitivity of 9280 kPa−1
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Flexible pressure sensors with high sensitivity are desired in the fields of electronic skins, human–machine interfaces, and health monitoring. Employing ionic soft materials with microstructured architectures in the functional layer is an effective way that can enhance the amplitude of capacitance signal due to generated electron double layer and thus improve the sensitivity of capacitive-type pressure sensors. However, the requirement of specific apparatus and the complex fabrication process to build such microstructures lead to high cost and low productivity. Here, we report a simple strategy that uses open-cell polyurethane foams with high porosity as a continuous three-dimensional network skeleton to load with ionic liquid in a one-step soak process, serving as the ionic layer in iontronic pressure sensors. The high porosity (95.4%) of PU-IL composite foam shows a pretty low Young’s modulus of 3.4 kPa and good compressibility. A superhigh maximum sensitivity of 9,280 kPa−1 in the pressure regime and a high pressure resolution of 0.125% are observed in this foam-based pressure sensor. The device also exhibits remarkable mechanical stability over 5,000 compression-release or bending-release cycles. Such high porosity of composite structure provides a simple, cost-effective and scalable way to fabricate super sensitive pressure sensor, which has prominent capability in applications of water wave detection, underwater vibration sensing, and mechanical fault monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 1×
“Such a problem can be addressed by introducing diverse microstructures into the dielectric layer to improve its compressibility [10, 11].”
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Learning the signatures of the human grasp using a scalable tactile glove
Sundaram, S., Kellnhofer, P., Li, Y., Zhu, J.-Y., Torralba, A., & Matusik, W. (2019) · Nature · doi:10.1038/s41586-019-1234-z · Cited by 1,162
Droplet-based interfacial capacitive sensing
Nie, B., Xing, S., Brandt, J. D., & Pan, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21168h · Cited by 216 · cited 1×
“In recent years, ionic conductors have been used to replace the traditional dielectric in capacitive sensors [12, 13].”
Cited by
Yang, R., Dutta, A., Li, B., Tiwari, N., Zhang, W., Niu, Z., Gao, Y., Erdely, D., Xin, X., Li, T., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38274-2 · Cited by 390
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics
Lu, Y., Yang, G., Shen, Y., Yang, H., & Xu, K. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00895-5 · Cited by 320
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
A robotic sensory system with high spatiotemporal resolution for texture recognition
Bai, N., Xue, Y., Chen, S., Shi, L., Shi, J., Zhang, Y., Hou, X., Cheng, Y., Huang, K., Wang, W., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42722-4 · Cited by 233
Self-citationYuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
Metadata
- Authors
- Liu, Q., Liu, Y., Shi, J., Liu, Z., Wang, Q., & Guo, C. F.
- Venue
- Nano-Micro Letters
- Published
- 2021-12-09
- Volume
- 14
- Issue
- 1
- Pages
- 21-21
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W4200404875
- Cited by
- 216
- References
- 4
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Porosity Foam-Based Iontronic Pressure Sensor with Superhigh Sensitivity of 9280 kPa−1. https://app.cochat.ai/papers/10.1007/s40820-021-00770-9
- The paper
- Liu, Q., Liu, Y., Shi, J., Liu, Z., Wang, Q., & Guo, C. F. (2022). High-Porosity Foam-Based Iontronic Pressure Sensor with Superhigh Sensitivity of 9280 kPa−1. Nano-Micro Letters. https://doi.org/10.1007/s40820-021-00770-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.