Fire Intumescent, High-Temperature Resistant, Mechanically Flexible Graphene Oxide Network for Exceptional Fire Shielding and Ultra-Fast Fire Warning
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Smart fire alarm sensor (FAS) materials with mechanically robust, excellent flame retardancy as well as ultra-sensitive temperature-responsive capability are highly attractive platforms for fire safety application. However, most reported FAS materials can hardly provide sensitive, continuous and reliable alarm signal output due to their undesirable temperature-responsive, flame-resistant and mechanical performances. To overcome these hurdles, herein, we utilize the multi-amino molecule, named HCPA, that can serve as triple-roles including cross-linker, fire retardant and reducing agent for decorating graphene oxide (GO) sheets and obtaining the GO/HCPA hybrid networks. Benefiting from the formation of multi-interactions in hybrid network, the optimized GO/HCPA network exhibits significant increment in mechanical strength, e.g., tensile strength and toughness increase of ~ 2.3 and ~ 5.7 times, respectively, compared to the control one. More importantly, based on P and N doping and promoting thermal reduction effect on GO network, the excellent flame retardancy (withstanding ~ 1200 °C flame attack), ultra-fast fire alarm response time (~ 0.6 s) and ultra-long alarming period (> 600 s) are obtained, representing the best comprehensive performance of GO-based FAS counterparts. Furthermore, based on GO/HCPA network, the fireproof coating is constructed and applied in polymer foam and exhibited exceptional fire shielding performance. This work provides a new idea for designing and fabricating desirable FAS materials and fireproof coatings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bowman, D. M. J. S., Balch, J. K., Artaxo, P., Bond, W. J., Carlson, J. M., Cochrane, M. A., D’Antonio, C. M., DeFries, R. S., Doyle, J. C., Harrison, S. P., et al. (2009) · Science · doi:10.1126/science.1163886 · Cited by 3,351
Ma, Z., Liu, X., Xu, X., Liu, L., Yu, B., Maluk, C., Huang, G., Wang, H., & Song, P. (2021) · ACS Nano · doi:10.1021/acsnano.1c02254 · Cited by 408 · cited 3×
“It is reported that this tragic accident led to 71 people deaths and the main reason is that the exterior cladding of this building is made of flammable polymer foam materials instead of a fireproof alternative [9, 12].”
BackgroundSelf-citationWu, Q., Gong, L.-X., Li, Y., Cao, C.-F., Tang, L.-C., Wu, L., Zhao, L., Zhang, G.-D., Li, S.-N., Gao, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b06590 · Cited by 305
Self-citationGuo, K.-Y., Wu, Q., Mao, M., Chen, H., Zhang, G.-D., Zhao, L., Gao, J.-F., Song, P., & Tang, L.-C. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108017 · Cited by 281 · cited 2×
“Thirdly, HCPA mol‐ ecules can also be employed as reducing agent to promote the thermal‐reduction process of GO sheets under high temperature or flame attack conditions, due to the existence of P and N atoms [40, 42, 43].”
BackgroundSelf-citationMao, M., Yu, K.-X., Cao, C.-F., Gong, L.-X., Zhang, G.-D., Zhao, L., Song, P., Gao, J.-F., & Tang, L.-C. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.131615 · Cited by 276
Self-citationSong, P., Xu, Z., Wu, Y., Cheng, Q., Guo, Q., & Wang, H. (2017) · Carbon · doi:10.1016/j.carbon.2016.10.067 · Cited by 216
Self-citationMultifunctional MXene/Chitosan-Coated Cotton Fabric for Intelligent Fire Protection
Wang, B., Lai, X., Li, H., Jiang, C., Gao, J., & Zeng, X. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c05222 · Cited by 204
Liu, L., Zhu, M., Xu, X., Li, X., Ma, Z., Jiang, Z., Pich, A., Wang, H., & Song, P. (2021) · Advanced Materials · doi:10.1002/adma.202105829 · Cited by 203
Self-citationA Large‐Area, Flexible, and Flame‐Retardant Graphene Paper
Dong, L., Hu, C., Song, L., Huang, X., Chen, N., & Qu, L. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504470 · Cited by 196
Yu, Z.-R., Mao, M., Li, S.-N., Xia, Q.-Q., Cao, C.-F., Zhao, L., Zhang, G.-D., Zheng, Z.-J., Gao, J.-F., & Tang, L.-C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126620 · Cited by 189 · cited 1×
“By contrast, the electrical resistance of pure GO paper was almost unchanged within 300 s under the same condition according to our previous work [51, 58].”
ResultSelf-citation
Cited by
Smart fire-warning materials and sensors: Design principle, performances, and applications
Lv, L.-Y., Cao, C.-F., Qu, Y.-X., Zhang, G.-D., Zhao, L., Cao, K., Song, P., & Tang, L.-C. (2022) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2022.100690 · Cited by 266
Self-citationCao, C.-F., Yu, B., Huang, J., Feng, X.-L., Lv, L.-Y., Sun, F.-N., Tang, L.-C., Feng, J., Song, P., & Wang, H. (2022) · ACS Nano · doi:10.1021/acsnano.2c08368 · Cited by 167
Self-citation
Metadata
- Authors
- Cao, C.-F., Yu, B., Chen, Z.-Y., Qu, Y.-X., Li, Y.-T., Shi, Y.-Q., Ma, Z.-W., Sun, F.-N., Pan, Q.-H., Tang, L.-C., Song, P., & Wang, H.
- Venue
- Nano-Micro Letters
- Published
- 2022-04-06
- Volume
- 14
- Issue
- 1
- Pages
- 92-92
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W4224313845
- Cited by
- 224
- References
- 51
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.