The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Humidity Sensing of Stretchable and Transparent Hydrogel Films for Wireless Respiration Monitoring
Open accessAbstract
Respiratory monitoring plays a pivotal role in health assessment and provides an important application prospect for flexible humidity sensors. However, traditional humidity sensors suffer from a trade-off between deformability, sensitivity, and transparency, and thus the development of high-performance, stretchable, and low-cost humidity sensors is urgently needed as wearable electronics. Here, ultrasensitive, highly deformable, and transparent humidity sensors are fabricated based on cost-effective polyacrylamide-based double network hydrogels. Concomitantly, a general method for preparing hydrogel films with controllable thickness is proposed to boost the sensitivity of hydrogel-based sensors due to the extensively increased specific surface area, which can be applied to different polymer networks and facilitate the development of flexible integrated electronics. In addition, sustainable tapioca rich in hydrophilic polar groups is introduced for the first time as a second cross-linked network, exhibiting excellent water adsorption capacity. Through the synergistic optimization of structure and composition, the obtained hydrogel film exhibits an ultrahigh sensitivity of 13,462.1%/%RH, which is unprecedented. Moreover, the hydrogel film-based sensor exhibits excellent repeatability and the ability to work normally under stretching with even enhanced sensitivity. As a proof of concept, we integrate the stretchable sensor with a specially designed wireless circuit and mask to fabricate a wireless respiratory interruption detection system with Bluetooth transmission, enabling real-time monitoring of human health status. This work provides a general strategy to construct high-performance, stretchable, and miniaturized hydrogel-based sensors as next-generation wearable devices for real-time monitoring of various physiological signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When the humidity increases to 33% RH, the complex EIS spectrum still exhibits a complete semicircle. However, the graded Warburg impedance is introduced, and short diagonal lines appear in the low-frequency region, as shown in Fig. 12c.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Spin coating, combined with sol–gel method, was used to prepare thin-film hydrogel humidity sensors with thicknesses of a few microns and sensitivity of up to 13,462.1% RH%−1, which exceeds that of bulk hydrogels (Fig. 12e).”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Liang et al. [206] prepared a transparent DN hydrogel with good mechanical deformability using PAM and cassava gum as raw materials, and introduced polyol and LiBr to further enhance its stability and reliability.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“When the humidity was continuously increased to 37–98% RH, the semicircular part of the complex EIS spectrum gradually disappeared, and the slash part was gradually elongated, as shown in Fig. 12d. In this humidity range, the Warburg impedance becomes the main factor of the EIS spectrum, and the hydrogel-sensitive film absorbs more water molecules, thereby forming a continuous hydrated layer”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“As shown in Fig. 12b, the complex EIS spectrum becomes semicircular under a dry environment. The amount of water molecules adsorbed by the sensitive film is small, and ion-conducting channels are not formed.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“Liang et al. [206] used electrochemical impedance spectroscopy (EIS) to detect the impedance changes of hydrogels at different humidity levels and confirmed their effects on the conductivity of hydrogels.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“Furthermore, the humidity response of the hydrogel was highly dependent on its thickness.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“The mask is able to recognize breathing patterns, demonstrating its potential application in sleep apnea disorders monitoring.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“The hydrogel sensor has a high sensitivity of 13,462.1% RH%−1 to humidity and can still operate in the stretched state.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
The cited source says what the claim attributes to it.
In the citing paper
“By integrating this hydrogel sensor, self-designed circuitry, and the mask, the authors also fabricated a mask that allows wireless breathing monitoring, as shown in Fig. 15c1-c2.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Liang et al. [206]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonaqueous Liquid Electrolytes for Lithium-Based Rechargeable Batteries
Xu, K. (2004) · Chemical Reviews · doi:10.1021/cr030203g · Cited by 7,653
Advanced Carbon for Flexible and Wearable Electronics
Wang, C., Xia, K., Wang, H., Liang, X., Yin, Z., & Zhang, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801072 · Cited by 1,312
Self-citationCellulose‐Based Flexible Functional Materials for Emerging Intelligent Electronics
Zhao, D., Zhu, Y., Cheng, W., Chen, W., Wu, Y., & Yu, H. (2020) · Advanced Materials · doi:10.1002/adma.202000619 · Cited by 857
Huang, Y., Zhong, M., Shi, F.-K., Liu, X., Tang, Z., Wang, Y., Huang, Y., Hou, H., Xie, X., & Zhi, C. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201705212 · Cited by 564
Skin-like mechanoresponsive self-healing ionic elastomer from supramolecular zwitterionic network
Zhang, W., Wu, B., Sun, S., & Wu, P. (2021) · Nature Communications · doi:10.1038/s41467-021-24382-4 · Cited by 556
Xiong, Y., Shen, Y., Lan, T., Hu, Y., Zhu, P., Sun, R., & Wong, C. (2020) · Nano Energy · doi:10.1016/j.nanoen.2019.104436 · Cited by 555
Flexible MXene‐Based Composites for Wearable Devices
Ma, C., Ma, M., Si, C., Ji, X., & Wan, P. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009524 · Cited by 553
Solution-processable, soft, self-adhesive, and conductive polymer composites for soft electronics
Tan, P., Wang, H., Xiao, F., Lu, X., Shang, W., Deng, X., Song, H., Xu, Z., Cao, J., Gan, T., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28027-y · Cited by 419
Self-citationHighly conductive and elastic nanomembrane for skin electronics
Jung, D., Lim, C., Shim, H. J., Kim, Y., Park, C., Jung, J., Han, S. I., Sunwoo, S.-H., Cho, K. W., Cha, G. D., et al. (2021) · Science · doi:10.1126/science.abh4357 · Cited by 403
Lan, L., Le, X., Dong, H., Xie, J., Ying, Y. B., & Ping, J. F. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112360 · Cited by 397
Cited by
Sorted by citations
Kong, L., Li, W., Zhang, T., Ma, H., Cao, Y., Wang, K., Zhou, Y., Shamim, A., Zheng, L., Wang, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202400333 · Cited by 240
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
“Liang et al. [206] prepared a transparent DN hydrogel with good mechanical deformability using PAM and cassava gum as raw materials, and introduced polyol and LiBr to further enhance its stability and reliability.”
BackgroundMethodInfluentialSelf-citationNi, Y., Zang, X., Yang, Y. S., Gong, Z., Li, H., Chen, J., Wu, C., Huang, J., & Lai, Y. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202402853 · Cited by 227
Guo, P., Tian, B., Liang, J., Yang, X., Tang, G., Li, Q., Liu, Q., Zheng, K., Chen, X., & Wu, W. H. (2023) · Advanced Materials · doi:10.1002/adma.202304420 · Cited by 185
Huang, W., Ding, Q., Wang, H., Wu, Z., Luo, Y., Shi, W., Yang, L., Liang, Y., Liu, C., & Wu, J. (2023) · Nature Communications · doi:10.1038/s41467-023-40953-z · Cited by 167
Self-citation
Metadata
- Authors
- Liang, Y., Ding, Q., Wang, H., Wu, Z., Li, J., Li, Z., Tao, K., Gui, X., & Wu, J.
- Affiliations
- Sun Yat-sen University (CN)
- Northwestern Polytechnical University (CN)
- Corresponding author
- Wu, Jin
- Venue
- Nano-Micro Letters
- Published
- 2022-09-12
- Volume
- 14
- Issue
- 1
- Pages
- 183-183
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- PMC
- PMC9468213
- OpenAlex
- W4295242544
- Cited by
- 162
- References
- 66
- Citations by year
- 2026: 26 · 2025: 51 · 2024: 44 · 2023: 38 · 2022: 3
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Nano-Micro Letters (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Shanghai Jiao Tong University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- humidity sensing, stretchable hydrogels, double-network hydrogel, polyacrylamide, tapioca, water adsorption, wearable electronics, Bluetooth communication, physiological monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›