The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Metals for bone implants: safety, design, and efficacy
Open accessAbstract
Like most bone deficits, mandibular segmental defects may result from surgical reconstruction due to congenital deformity, tumor resection, other pathologies, senescence, trauma, or infection. The goals of mandibular reconstruction are to restore the mandible’s function and normal appearance. Clinical methods to restore the mandible typically rely on bone replacement using some combination of bone tissue transfer and metal implants. This paper reviews the safety, design, and efficacy of metal implants in general and specifically for the repair of mandibular segmental defects. These problems include implant incorporation, implant failure mechanisms (e.g., stress concentration, stress shielding), corrosion and toxicity, infection, and muscle re-attachment. Finally, this paper presents the use of porous nickel-titanium (NiTi) implants for the repair of skeletal defects through the example of mandibular segmental defects. Resorbable magnesium, and porous and non-porous NiTi, immobilization hardware are also discussed. These materials provide new options which may better match the material properties, and if they can be 3D printed, better match the shape of surrounding host tissue. These advances might reduce engrafted bone and metal implant failure and restore musculoskeletal function for the long term. Patient-specific hardware and grafting strategies might prove to be useful tools in determining both the patient’s appearance and functional outcome following reconstructive musculoskeletal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Cited by
A comprehensive review on metallic implant biomaterials and their subtractive manufacturing
Davis, R., Singh, A., Jackson, M. J., Coelho, R. T., Prakash, D., Charalambous, C. P., Ahmed, W., da Silva, L. R. R., & Lawrence, A. A. (2022) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-022-08770-8 · Cited by 380
Bairagi, D., & Mandal, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.09.005 · Cited by 272
Recent Advancements in Materials and Coatings for Biomedical Implants
Amirtharaj Mosas, K. K., Chandrasekar, A. R., Dasan, A., Pakseresht, A., & Galusek, D. (2022) · Gels · doi:10.3390/gels8050323 · Cited by 256
Martinez, D. C., Borkam-Schuster, A., Helmholz, H., Dobkowska, A., Luthringer-Feyerabend, B., Płociński, T., Willumeit-Römer, R., & Święszkowski, W. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.08.015 · Cited by 21
Metadata
- Authors
- Shayesteh Moghaddam, N., Taheri Andani, M., Amerinatanzi, A., Haberland, C., Huff, S., Miller, M., Elahinia, M., & Dean, D.
- Venue
- Biomanufacturing Reviews
- Published
- 2016-10-06
- Volume
- 1
- Issue
- 1
- ISSN
- 2363-507X (ISSN-L)
- 2363-5088
- OpenAlex
- W2528726436
- Cited by
- 184
- References
- 2
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metals for bone implants: safety, design, and efficacy. https://app.cochat.ai/papers/10.1007/s40898-016-0001-2
- The paper
- Shayesteh Moghaddam, N., Taheri Andani, M., Amerinatanzi, A., Haberland, C., Huff, S., Miller, M., Elahinia, M., & Dean, D. (2016). Metals for bone implants: safety, design, and efficacy. Biomanufacturing Reviews. https://doi.org/10.1007/s40898-016-0001-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.