Cited by 3Radiation Dose and ImagingAdvanced Radiotherapy TechniquesDigital Radiography and Breast Imaging

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Optimization and image quality in CT studies: application of DRLs based on clinical indication

Open access

Abstract

The use of ionizing radiation in computed tomography (CT) has significantly enhanced diagnostic accuracy and clinical decision-making. However, optimizing CT protocols is crucial to balance the diagnostic benefits with potential radiation risks, particularly for vulnerable populations. Diagnostic Reference Levels (DRLs), introduced to guide dose optimization, highlight variations in dose indices due to local protocol differences rather than patient or equipment characteristics. This underscores the importance of standardizing technical parameters to ensure consistent image quality and minimize dose variability. Recent advancements, including iterative reconstruction algorithms and artificial intelligence, offer promising avenues for dose reduction without compromising diagnostic value. Effective optimization strategies require a multidisciplinary approach, incorporating continuous protocol evaluation, adherence to quality assurance programs, and clinical audits. Standardized DRLs tailored to clinical indications further enhance imaging practices, reducing variability and fostering safer, more effective patient care. The purpose of this article is to demonstrate, through a review of the literature and recent papers, applied to clinical practice, the role of diagnostic reference levels (DRLs) in CT optimization and image’s quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s42452-025-07125-8

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Sorted by citations

See all 3

Metadata

Authors
Picone, C., Porto, A., Fusco, R., Granata, C., Brunese, M. C., Granata, V., Ottaiano, A., Barretta, M., Caranci, F., Pecori, B., Sorgente, E., Salerno, S., Mormile, R., Pinto, F., Pinto, A., Magistrelli, A., & Petrillo, A.
Affiliations
  • Istituto Nazionale Tumori IRCCS "Fondazione G. Pascale" (IT)
  • IRCCS Materno Infantile Burlo Garofolo (IT)
  • University of Molise (IT)
  • University of Campania "Luigi Vanvitelli" (IT)
  • University of Palermo (IT)
  • Azienda Ospedaliera S.Giuseppe Moscati (IT)
  • Bambino Gesù Children's Hospital (IT)
Corresponding author
Picone, Carmine
Venue
Discover Applied Sciences
Published
2025-05-22
Volume
7
Issue
6
ISSN
3004-9261 (ISSN-L)
OpenAlex
W4410614211
Cited by
3
References
17
Citations by year
2026: 2 · 2025: 1
FWCI
1.74
Type
journal article
Language
en
Open access
Locations
  • Discover Applied Sciences (publishedVersion, cc-by-nc-nd)
  • CINECA IRIS Institutional Research Information System (University of Basilicata) (submittedVersion, public-domain)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Nova Science Publishers (Nova Science Publishers, Inc.) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
Keywords
diagnostic reference levels, CT dose optimization, radiation dose reduction, image quality, iterative reconstruction, quality assurance, clinical audit, protocol standardization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review