Cited by 95Cardiovascular Syncope and Autonomic DisordersCardiac pacing and defibrillation studiesHeart Rate Variability and Autonomic Control

Carotid sinus hypersensitivity: beneficial effects of dual-chamber pacing

Madigan, Niall P., Flaker, Greg C., Curtis, Jack J., Reid, John, Mueller, Karl J., Murphy, Thomas J.·1984·The American Journal of Cardiology

Abstract

Three types of carotid sinus (CS) syndrome have been described: cardioinhibitory, vasodepressor and mixed. For the treatment of symptomatic patients with associated significant cardioinhibition, permanent ventricular demand pacing systems are often implanted. Even with this pacing modality, some patients remain symptomatic because of continued (and at times aggravated) vasodepression. This study assesses the effects of loss of atrial preloading and orthostasis after carotid massage in patients with CS hypersensitivity. Eleven patients were studied using constant intra-arterial pressure measurements during either ventricular (VVI) or atrioventricular sequential (DVI) pacing in both supine or upright positions. The measurements performed included the magnitude of decrease in arterial blood pressure (BP), the rate of decrease of BP and the percent change in BP from baseline values. After carotid massage, all 11 patients had greater hemodynamic change with the VVI than DVI pacing mode, whether in the supine or upright position. The decreases in systolic BP were: DVI (supine) 29 mm Hg, VVI (supine) 48 mm Hg, DVI (upright) 37 mm Hg, and VVI (upright) 59 mm Hg (mean group values, p less than 0.001). The rates of decrease of systolic BP were: DVI (supine) 2.9 mm Hg/s, VVI (supine) 5.7 mm Hg/s, DVI (upright) 4.1 mm Hg/s, and VVI (upright) 8.3 mm Hg/s (mean group values, p less than 0.001). VVI pacing, particularly in the upright position, resulted in a significant increase in the incidence of patient symptoms (p = 0.03). Thus, in CS hypersensitivity, VVI pacing results in significant hemodynamic deterioration compared to DVI mode. This aggravation of the vasodepressor component results in increased patient symptoms, and therefore, DVI is the optimal pacing mode.

Integrity signals

Registry

Crossref · 10.1016/0002-9149(84)90632-5

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In CSS, dual-chamber pacing is better than single-chamber ventricular mode in counteracting BP fall during CSM and in preventing symptom recurrences.

    “In CSS, a few small controlled studies 304,305 and one registry 306 showed that dual-chamber pacing is better than the single chamber ventricular mode in counteracting BP fall during CSM and in preventing symptom recurrences.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Madigan, N. P., Flaker, G. C., Curtis, J. J., Reid, J., Mueller, K. J., & Murphy, T. J.
Affiliations
University of Missouri (US)
Corresponding author
Madigan, Niall P.
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
1984-04
Volume
53
Issue
8
Pages
1034-1040
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2005825052
Cited by
95
References
33
Citations by year
2026: 1 · 2023: 1 · 2021: 1 · 2018: 4 · 2017: 7 · 2016: 1 · 2014: 5 · 2013: 3 · 2012: 1
FWCI
8.00
Type
journal article
Language
en
Open access
closed
Locations
  • The American Journal of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
carotid sinus hypersensitivity, carotid sinus syndrome, DDD pacing, ventricular demand pacing, VVI pacing, vasodepression, cardioinhibition, orthostatic blood pressure, hemodynamic response
MeSH terms
Adult, Aged, Blood Pressure, Cardiac Pacing, Artificial, Carotid Sinus, Female, Heart Conduction System, Hemodynamics, Humans, Male, Massage, Middle Aged, Posture, Venous Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›