Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 264

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry

Loo, Joseph A., Udseth, Harold R., Smith, Richard D.·1989·Analytical Biochemistry

Abstract

The extension of mass spectrometry to high molecular weight biopolymers based upon electrospray ionization and the on-line combination with capillary electrophoresis is described. Electrospray ionization produces gas-phase intact multiply charged molecular ions of biomolecules from highly charged liquid droplets by a high electric field. For high molecular weight substances electrospray ionization results in a characteristic bell-shaped distribution of multiply charged ions, with each adjacent major peak in the spectrum differing by one charge. Multiply charged molecular ions of proteins with molecular weights greater than 130,000 have been observed with a quadrupole mass spectrometer of limited mass-to-charge range (m/z 1700). Molecular weights can be readily determined for large proteins with accuracies in the range of +/- 0.01 to 0.05%; at least an order of magnitude further improvement appears feasible with improved techniques and instrumentation. The electrospray ionization method is sensitive, presently requiring samples in the 100 fmol to 10 pmol range for proteins. Initial results combining rapid separations by capillary zone electrophoresis with on-line mass spectrometric detection via the electrospray ionization source are demonstrated for myoglobin and other proteins and polypeptides. The potential for extension of these methods to molecular weights on the order of 10(6) is discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0003-2697(89)90153-x

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 264

Metadata

Authors
Loo, J. A., Udseth, H. R., & Smith, R. D.
Venue
Analytical Biochemistry
Publisher
Elsevier BV
Published
1989-06
Volume
179
Issue
2
Pages
404-412
ISSN
0003-2697 (ISSN-L)
OpenAlex
W2054001308
Cited by
264
References
20
FWCI
28.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry. https://app.cochat.ai/papers/10.1016/0003-2697(89)90153-x
The paper
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989). Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry. Analytical Biochemistry. https://doi.org/10.1016/0003-2697(89)90153-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.