Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The extension of mass spectrometry to high molecular weight biopolymers based upon electrospray ionization and the on-line combination with capillary electrophoresis is described. Electrospray ionization produces gas-phase intact multiply charged molecular ions of biomolecules from highly charged liquid droplets by a high electric field. For high molecular weight substances electrospray ionization results in a characteristic bell-shaped distribution of multiply charged ions, with each adjacent major peak in the spectrum differing by one charge. Multiply charged molecular ions of proteins with molecular weights greater than 130,000 have been observed with a quadrupole mass spectrometer of limited mass-to-charge range (m/z 1700). Molecular weights can be readily determined for large proteins with accuracies in the range of +/- 0.01 to 0.05%; at least an order of magnitude further improvement appears feasible with improved techniques and instrumentation. The electrospray ionization method is sensitive, presently requiring samples in the 100 fmol to 10 pmol range for proteins. Initial results combining rapid separations by capillary zone electrophoresis with on-line mass spectrometric detection via the electrospray ionization source are demonstrated for myoglobin and other proteins and polypeptides. The potential for extension of these methods to molecular weights on the order of 10(6) is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Capillary Zone Electrophoresis
Jorgenson, J. W., & Lukacs, K. D. (1983) · Science · doi:10.1126/science.6623076 · Cited by 1,289
On-line mass spectrometric detection for capillary zone electrophoresis
Olivares, J. A., Nguyen, N. T., Yonker, C. R., & Smith, R. D. (1987) · Analytical Chemistry · doi:10.1021/ac00135a034 · Cited by 635
Self-citationMcCormick, R. M. (1988) · Analytical Chemistry · doi:10.1021/ac00172a003 · Cited by 621
Capillary zone electrophoresis of proteins in untreated fused silica tubing
Lauer, H. H., & McManigill, D. (1986) · Analytical Chemistry · doi:10.1021/ac00292a041 · Cited by 616
Mass spectrometric determination of the amino acid sequence of peptides and proteins
Biemann, K., & Martin, S. A. (1987) · Mass Spectrometry Reviews · doi:10.1002/mas.1280060102 · Cited by 554
Improved electrospray ionization interface for capillary zone electrophoresis-mass spectrometry
Smith, R. D., Barinaga, C. J., & Udseth, H. R. (1988) · Analytical Chemistry · doi:10.1021/ac00169a022 · Cited by 535
Self-citation
Cited by
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Self-citationSmith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Self-citationAdvances in Chemical and Biological Methods to Identify Microorganisms—From Past to Present
Franco-Duarte, R., Černáková, L., Kadam, S., S. Kaushik, K., Salehi, B., Bevilacqua, A., Corbo, M. R., Antolak, H., Dybka-Stępień, K., Leszczewicz, M., et al. (2019) · Microorganisms · doi:10.3390/microorganisms7050130 · Cited by 565
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Self-citationSenko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Self-citationAn electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
High-performance capillary electrophoresis in the biological sciences
Karger, B. L., Cohen, A. S., & Guttman, A. (1989) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)84480-1 · Cited by 316
Beavis, R. C., & Chait, B. T. (1990) · Analytical Chemistry · doi:10.1021/ac00216a020 · Cited by 314
Loo, J. A., Edmonds, C. G., & Smith, R. D. (1990) · Science · doi:10.1126/science.2326633 · Cited by 300
Self-citationSmith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Self-citationBaudier, J., Deloulme, J. C., Van Dorsselaer, A., Black, D., & Matthes, H. W. (1991) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)52425-x · Cited by 274
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
Self-citationElectrospray ionization combined with ion trap mass spectrometry
Van Berkel, G. J., Glish, G. L., & McLuckey, S. A. (1990) · Analytical Chemistry · doi:10.1021/ac00212a016 · Cited by 246
Smith, R. D., Loa, J. A., Barinaga, C. J., Edmonds, C. G., & Udseth, H. R. (1990) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(90)80006-9 · Cited by 244
Self-citationFourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
Matrix‐assisted laser‐desorption mass spectrometry using 355 nm radiation
Beavis, R. C., Chait, B. T., & Standing, K. G. (1989) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290031208 · Cited by 190
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48
Status of, and developments in, mass spectrometry of peptides and proteins
Roepstorff, P., & Richter, W. J. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85085-e · Cited by 15
Metadata
- Authors
- Loo, J. A., Udseth, H. R., & Smith, R. D.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1989-06
- Volume
- 179
- Issue
- 2
- Pages
- 404-412
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2054001308
- Cited by
- 264
- References
- 20
- FWCI
- 28.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.