Error bounds for EEG and MEG dipole source localization
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MUSIC, maximum likelihood, and Cramer-Rao bound
Stoica, P., & Nehorai, A. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.17564 · Cited by 2,820 · cited 2×
“and the dipole moments and locations grouped as defined above, the Fisher Information Matrix is (Stoica and Nehorai 1989)”
BackgroundMethodBasic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 2×
“(1985) and Sarvas (1987), the non- rad ia l sensor”
BackgroundMultiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationLocation of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300 · cited 9×
“Indeed, the minor axes of t h e ellipsoid represent the "preferred directions" discussed in Cohen and Cuffin (1983). If we consider the errors in any direction to be equally important, then we can ignore this directional bias and, instead, focus on the scalar length of this error vector.”
BackgroundMethodResultInfluentialMEG versus EEG localization test using implanted sources in the human brain
Cohen, D., Cuffin, B. N., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J., Kennedy, J. G., & Schomer, D. L. (1990) · Annals of Neurology · doi:10.1002/ana.410280613 · Cited by 294 · cited 1×
“1991) and to compare localization errors between EEG and M E G (Cohen et al. 1990).”
ResultComparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
Assessment [RETIRED]: Magnetoencephalography (MEG)
(1992) · Neurology · doi:10.1212/wnl.42.1.1 · Cited by 232
The Electric Field of an Eccentric Dipole in a Homogeneous Spherical Conducting Medium
WILSON, F. N., & BAYLEY, R. H. (1950) · Circulation · doi:10.1161/01.cir.1.1.84 · Cited by 192 · cited 1×
“The earliest models were for the dipole in a single homogeneous sphere (Wilson and Bayley 1950), which led to a closed form solution (Brody et al.”
BackgroundEffects of head shape on EEGs and MEGs
Cuffin, B. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 153
An Evaluation of Methods for Neuromagnetic Image Reconstruction
Jeffs, B., Leahy, R., & Singh, M. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325996 · Cited by 149 · cited 1×
“Jeffs et al. (1987) showed that this practice is a reasonable approximation by comparing point models with integrations across the coil diameters.”
MethodSelf-citationThe influence of model parameters on EEG/MEG single dipole source estimation
Stok, C. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326090 · Cited by 146
Eccentric Dipole in a Spherical Medium: Generalized Expression for Surface Potentials
Brody, D. A., Terry, F. H., & Ideker, R. E. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324177 · Cited by 107 · cited 2×
“This analysis confirms the hypotheses of Cohen and Cuffin (1983), Anogianakis et al.”
BackgroundResultEffect of Inhomogeneities on the Apparent Location and Magnitude of a Cardiac Current Dipole Source
Arthur, R. M., & Geselowitz, D. B. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502713 · Cited by 93
Methodological considerations for the evaluation of spatio-temporal source models
Achim, A., Richer, F., & Saint-Hilaire, J. M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90140-y · Cited by 77 · cited 10×
“(1991) and Achim et al. (1991) may have benefited from using these spatiotemporal CRLBs as a rapid analysis tool in interpreting their specific case studies of dipole locations and time series.”
BackgroundMethodResultInfluentialZhou, H., & van Oosterom, A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.121646 · Cited by 76
Spatiotemporal modeling of cerebral evoked magnetic fields to median nerve stimulation
Baumgartner, C., Sutherling, W. W., Di, S., & Barth, D. S. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90153-u · Cited by 73
Dipole source localization in the study of EP generators: a critique
Snyder, A. Z. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90116-f · Cited by 62
Signals and Noise in Evoked Brain Potentials
McGillen, C. D., Aunon, J. I., & Yu, K. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325510 · Cited by 48
A consensus statement on relative merits of EEG and MEG
Anogianakis, G., Badier, J., Barrett, G., Erne, S. N., Fenici, R., Fenwick, P. B. C., Grandori, F., Hari, R., Ilmoniemi, R. J., Mauguìere, F., et al. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90001-x · Cited by 40 · cited 1×
“This analysis confirms the hypotheses of Cohen and Cuffin (1983), Anogianakis et al. (1992) and Therapeutics and Technology Assessment Subcommittee (1992) concerning the potential for directly combining EEG and MEG measurements into an overall superior resolution ability, unachievable by either modality alone.”
ResultOn cortical folds and neuromagnetic fields
Kaufman, L., Kaufman, J. H., & Wang, J.-Z. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90139-u · Cited by 38
MEG versus EEG localization test
Hari, R., Hämäläinen, M., Ilmoniemi, R. J., & Lounasmaa, O. V. (1991) · Annals of Neurology · doi:10.1002/ana.410300221 · Cited by 28
MEG versus EEG localization test
Williamson, S. J. (1991) · Annals of Neurology · doi:10.1002/ana.410300220 · Cited by 22
Spatial localization of neural sources using the magnetoencephalogram
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1990) · ASSP Workshop on Spectrum Estimation and Modeling · doi:10.1109/spect.1990.205593 · Cited by 7 · cited 5×
“Variations of SNR(array) are common definitions in other studies (Cuffin and Cohen 1979; Cuffin 1986; Mosher et al. 1990; Oshiro et al. 1992), in which it is therefore not necessary to assign explicit units of amps to the dipole current.”
BackgroundMethodResultInfluentialSelf-citation
Cited by
The Human Connectome Project: A data acquisition perspective
Van Essen, D. C., Ugurbil, K., Auerbach, E., Barch, D., Behrens, T. E. J., Bucholz, R., Chang, A., Chen, L., Corbetta, M., Curtiss, S. W., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.018 · Cited by 2,680
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
Self-citationA sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG
Huang, M. X., Mosher, J. C., & Leahy, R. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/2/010 · Cited by 612
Self-citationMultiple sparse priors for the M/EEG inverse problem.
Friston, K., Harrison, L., Daunizeau, J., Kiebel, S., Phillips, C., Trujillo-Barreto, N., Henson, R., Flandin, G., & Mattout, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.048 · Cited by 589
“Adding dipoles and noise to simulations characteristically compromises localization performance (see Mosher et al., 1993; Russell et al., 1998).”
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Metadata
- Authors
- Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1993-05
- Volume
- 86
- Issue
- 5
- Pages
- 303-321
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2056363696
- Cited by
- 233
- References
- 24
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.