A theoretical model for stress-generated fluid flow in the canaliculi-lacunae network in bone tissue
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Biochemistry and Physiology of Bone
(1956) · Journal of the American Medical Association · doi:10.1001/jama.1956.02970180082039 · Cited by 861
Transport mechanism operating between blood supply and osteocytes in long bones
PIEKARSKI, K., & MUNRO, M. (1977) · Nature · doi:10.1038/269080a0 · Cited by 449
Scanning Electron Microscope Studies of Bone
BOYDE, A. (1972) · The Biology and Physiology of Bone · doi:10.1016/b978-0-12-119201-3.50015-9 · Cited by 196
Frost, H. M. (1960) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196042010-00011 · Cited by 191
An anatomical model for streaming potentials in osteons
Pollack, S. R., Petrov, N., Salzstein, R. A., Brankov, G. I., & Blagoeva, R. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90094-0 · Cited by 98
Hm, F. (1960) · PubMed · Cited by 44
Theoretical evidence for the generation of high pressure in bone cells
Jendrucko, R. J., Hyman, W. A., Newell, P. H., & Chakraborty, B. K. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90127-5 · Cited by 25
Cited by
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Cowin, S. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00161-4 · Cited by 780
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
“neglected both the presence of the cell process and the pericellular matrix in the canaliculi [33].”
BackgroundBiomaterials and bone mechanotransduction
Sikavitsas, V. I., Temenoff, J. S., & Mikos, A. G. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00002-3 · Cited by 519
Molecular pathways mediating mechanical signaling in bone
Rubin, J., Rubin, C., & Jacobs, C. R. (2006) · Gene · doi:10.1016/j.gene.2005.10.028 · Cited by 474
Differential effect of steady versus oscillating flow on bone cells
Jacobs, C. R., Yellowley, C. E., Davis, B. R., Zhou, Z., Cimbala, J. M., & Donahue, H. J. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00114-6 · Cited by 453
Function of osteocytes in bone
Aarden, E. M., Nijweide, P. J., & Burger, E. H. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240550304 · Cited by 409
Fluid and Solute Transport in Bone: Flow-Induced Mechanotransduction
Fritton, S. P., & Weinbaum, S. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.010908.165136 · Cited by 380
You, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1287161 · Cited by 357
Genetos, D. C., Kephart, C. J., Zhang, Y., Yellowley, C. E., & Donahue, H. J. (2007) · Journal of Cellular Physiology · doi:10.1002/jcp.21021 · Cited by 328
Ultrastructure of the osteocyte process and its pericellular matrix
You, L., Weinbaum, S., Cowin, S. C., & Schaffler, M. B. (2004) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20050 · Cited by 326
“Whither flows the fluid in bone?” An osteocyte's perspective
Knothe Tate, M. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00123-4 · Cited by 309
A case for bone canaliculi as the anatomical site of strain generated potentials
Cowin, S. C., Weinbaum, S., & Zeng, Y. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00058-p · Cited by 303
Busse, B., Djonic, D., Milovanovic, P., Hahn, M., Püschel, K., Ritchie, R. O., Djuric, M., & Amling, M. (2010) · Aging Cell · doi:10.1111/j.1474-9726.2010.00633.x · Cited by 293
Price, C., Zhou, X., Li, W., & Wang, L. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.211 · Cited by 279
Review: Bone tissue engineering: The role of interstitial fluid flow
Hillsley, M. V., & Frangos, J. A. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430706 · Cited by 270
Effect of flow on prostaglandin E2 and inositol trisphosphate levels in osteoblasts
Reich, K. M., & Frangos, J. A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.261.3.c428 · Cited by 255
Osteocyte lacunae tissue strain in cortical bone
Nicolella, D. P., Moravits, D. E., Gale, A. M., Bonewald, L. F., & Lankford, J. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.032 · Cited by 253
Selective Laser Melting of Magnesium and Magnesium Alloy Powders: A Review
Manakari, V., Parande, G., & Gupta, M. (2016) · Metals · doi:10.3390/met7010002 · Cited by 241
“Human bone has a hierarchical structure with three major anatomic cavities of different sizes which are haversian canals (50 μm) [137], osteocytic lacunae (few micrometres) [15,138,139], and canaliculi (<1 μm) [140,141].”
BackgroundInduction of NO and prostaglandin E2in osteoblasts by wall-shear stress but not mechanical strain
Smalt, R., Mitchell, F. T., Howard, R. L., & Chambers, T. J. (1997) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1997.273.4.e751 · Cited by 220
“Mechanical loading of bone results in flow of interstitial fluid through the canalicular network (8, 14, 18).”
In situ measurement of solute transport in the bone lacunar-canalicular system
Wang, L., Wang, Y., Han, Y., Henderson, S. C., Majeska, R. J., Weinbaum, S., & Schaffler, M. B. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505193102 · Cited by 213
Estimation of the poroelastic parameters of cortical bone
Smit, T. H., Huyghe, J. M., & Cowin, S. C. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00021-0 · Cited by 208
Wang, X., & Ni, Q. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00157-2 · Cited by 203
Osteocyte Mechanobiology and Pericellular Mechanics
Jacobs, C. R., Temiyasathit, S., & Castillo, A. B. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105302 · Cited by 197
Cullinane, D. M., & Einhorn, T. A. (2002) · Principles of Bone Biology · doi:10.1016/b978-012098652-1.50104-9 · Cited by 195
Riddle, R. C., Taylor, A. F., Genetos, D. C., & Donahue, H. J. (2006) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00082.2005 · Cited by 193
“Several studies have suggested that increased bone formation in response to mechanical loading is mediated by the response of bone cells to strain-induced fluid flow (33, 64).”
BackgroundHistomorphometric study of alveolar bone turnover in orthodontic tooth movement
King, G. J., Keeling, S. D., & Wronski, T. J. (1991) · Bone · doi:10.1016/8756-3282(91)90029-i · Cited by 167
From streaming‐potentials to shear stress: 25 years of bone cell mechanotransduction
Riddle, R. C., & Donahue, H. J. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20723 · Cited by 157
“Within the confined geometry of lacunar-canalicular and haversian systems, interstitial fluid flow would impart shear stresses upon cell membranes and processes that were originally estimated to be up to 30 dynes/ cm(2).(17,18) More recent estimates suggest that fluid shear stresses range from 0 to 20 dynes/cm(2) depe…”
Background
Metadata
- Authors
- Kufahl, R. H., & Saha, S.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 23
- Issue
- 2
- Pages
- 171-180
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2051876520
- Cited by
- 176
- References
- 7
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.