Mechanical properties of trabecular bone. Dependency on strain rate
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma u), and ultimate strain (epsilon u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a rho b epsilon c, Y = rho b(a + c epsilon; Y = (a + b rho)epsilon c, Y = a rho 2 epsilon c, E = a rho 3 epsilon c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The compressive modulus and compressive strength are proportional to the strain rate raised to the power of 0.06 (100, 101).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [100]
Citations
Cites
(1962) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(62)91145-6 · Cited by 4,391
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical properties of cellular solids
Ashby, M. F., & Medalist, R. F. M. (1983) · Metallurgical Transactions A · doi:10.1007/bf02645546 · Cited by 1,137
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
The fabric dependence of the orthotropic elastic constants of cancellous bone
Turner, C. H., Cowin, S. C., Rho, J. Y., Ashman, R. B., & Rice, J. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90048-8 · Cited by 346
Research works printed but not linked: 4
- Cassidy, 1985, Mechanical and architectural properties in bovine cancellous bone, Trans. ORS, 10, 354
- Downey, 1987, Compressive loading raises intraosseous pressure in the femoral head, Trans. ORS, 12, 496
- Harrigan, 1981, The influence of apparent density and trabecular orientation on the elastic modulus of cancellous bone, Trans. ORS, 6, 277
- McElhaney, 1970, A Porous Block Model for Cancellous Bone
Cited by
Items 101–200 of 218
The Effect of Specimen Geometry on the Mechanical Behavior of Trabecular Bone Specimens
Ang, B. L. S., Tan, Y., Ng, Y. J. P., Ong, S., Yap, S. Y., Gwee, S. X., Chou, S. M., Poh, C. L., & Yew, K. (2012) · Diffusion and defect data, solid state data. Part B, Solid state phenomena/Solid state phenomena · doi:10.4028/www.scientific.net/ssp.185.129 · Cited by 15
Numerical investigations on the biomechanical compatibility of hip-joint endoprostheses
Lutz, A., & Nackenhorst, U. (2009) · Archive of Applied Mechanics · doi:10.1007/s00419-009-0380-4 · Cited by 15
Quasi-static and ratcheting properties of trabecular bone under uniaxial and cyclic compression
Gao, L., Wei, C.-L., Zhang, C., Gao, H. X., Yang, N., & Dong, L. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.214 · Cited by 14
Critical analysis on dynamic-mechanical performance of spongy bone: the effect of acrylic cement
Ronca, D., Gloria, A., Santis, R. D., Russo, T., D’Amora, U., Chierchia, M., Nicolais, L., & Ambrosio, L. (2014) · Cited by 14
Strain rate dependent poroelastic behavior of bovine vertebral trabecular bone
Hong, J. H., Mun, M. S., & Lim, T. H. (2001) · KSME International Journal · doi:10.1007/bf03185281 · Cited by 14
“This study indicated that the pore pressure gener ation coefficient called Skempton's coefficient of trabecular bone is much higher than that of cor tical bone ( Lim and Hong, 2000; Cowin, 1999).”
BackgroundMethodInfluentialBone Response to Mechanical Loads
Ramaswamy, G., Bidez, M. W., & Misch, C. E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-323-07845-0.00006-3 · Cited by 15
Kunnel, J. G., Gilbert, J. L., & Stern, P. H. (2002) · Calcified Tissue International · doi:10.1007/s00223-001-1073-3 · Cited by 13
Silva-Henao, J. D., Rueda‐Esteban, R. J., Marañón, A., & Casas, J. P. (2020) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2020.107053 · Cited by 12
Lee, K.-L., Baldassarri, M., Gupta, N., Pinisetty, D., Janal, M. N., Tovar, N., & Coelho, P. G. (2012) · International Journal of Biomaterials · doi:10.1155/2012/415230 · Cited by 12
“For higher loading rates, higher modulus and hardness are expected [17–19, 33].”
BackgroundMacro- and Microimaging of Bone Architecture
Jiang, Y., Zhao, J., & Genant, H. K. (2002) · Elsevier eBooks · doi:10.1016/b978-012098652-1.50195-5 · Cited by 12
Staged-Injection Procedure to Prevent Cement Leakage During Vertebroplasty: An In Vitro Study
Wu, Z., Lei, W., Hu, Y., Wang, H., Wan, S.-Y., Wang, J., & Han, Y. (2007) · Spine · doi:10.1097/brs.0b013e3181573976 · Cited by 11
Keßler, S., Mayr‐Wohlfart, U., Ignatius, A. A., Puhl, W., Claes, L., & Günther, K.-P. (2001) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s004020100265 · Cited by 11
“During the manufacturing process of solvent dehydrated bone, samples are weakened by the sterilization procedure [ 18 ], which can partly explain the differences between our implants prior to surgery and the controls.”
Methodde Brosses, E. S. , Briot, K., Kolta, S., Skalli, W., Roux, C., & Mitton, D. (2010) · IRBM · doi:10.1016/j.irbm.2010.02.014 · Cited by 11
Macro- and Microimaging of Bone Architecture
Engelke, K., Prevrhal, S., & Genant, H. K. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00089-6 · Cited by 11
Stress Shielding in Cemented Hip Implants Assessed from Computed Tomography
Goswami, T. (2019) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2019.18.003163 · Cited by 10
Effect of loading frequency on deformations at the bone–implant interface
Xie, S., Manda, K., & Pankaj, P. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919877970 · Cited by 9
Zheng, L., Huang, X., Li, C., Li, P., Lin, Z., & Huang, S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e12101 · Cited by 9
Teo, J. C. M., Teo, E. Y., Shim, V. P. W., & Teoh, S. H. (2006) · Experimental Mechanics · doi:10.1007/s11340-006-8444-7 · Cited by 9
“For instance, results from compression, tensile or shear testing of cancellous bones are dependent on specimen geometry [4], boundary [5] and loading conditions [ 6 ].”
BackgroundMethodShore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Model-based bone material property identification
Wilkie, J. A., Docherty, P. D., & Möller, K. (2020) · at - Automatisierungstechnik · doi:10.1515/auto-2020-0083 · Cited by 7
Loch, C., Viegas, S. V., Waddell, J. N., Kemper, C. M., Cook, R. B., & Werth, A. J. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103939 · Cited by 7
Estimating tissue-level properties of porcine talar subchondral bone
Koria, L., Mengoni, M., & Brockett, C. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103931 · Cited by 7
Poroelastic behavior of trabecular bone: The effect of strain rate
Hong, J. H., & Song, S.-H. (1998) · KSME International Journal · doi:10.1007/bf02946357 · Cited by 7
“Unlike elastic materials, however, trabecular bone exhibits time-dependent mechanical behavior such as stress relaxation, creep, influence of strain and loading rate input on its mechanical properties, and phase-shift phenomena under dynamic loading input (Carter and Hayes, 1977; Ducheyne et al., 1977; Linde et aL, 19…”
BackgroundWinter, W. (1993) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1993.38.1-2.10 · Cited by 7
Ramaniraka, N. A., Leyvraz, P. F., Rakotomanana, L. R., Rubin, P., & Zysset, P. K. (1996) · Hip International · doi:10.1177/112070009600600201 · Cited by 7
Gerber, G., Varga, P., Schwiedrzik, J. J., & Zysset, P. K. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107157 · Cited by 6
Pearce, D. J., Hitchens, P. L., Malekipour, F., Ayodele, B. A., Lee, P. V. S., & Whitton, R. C. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.923356 · Cited by 7
“(16) could also contribute to their greater total cartilage-bone specimen stiffness (33).”
BackgroundTrabecular Bone Poroelasticity for MicroCT-Based FE Models
Sandino, C., & Boyd, S. K. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6351-1_13 · Cited by 6
Effect of the Strain Rate on the Twisting of Trabecular Bone from Women with Hip Fracture
Vale, A. C., Faustino, J., Reis, L. G., Lopes, A., Vidal, B., Monteiro, J., Fonseca, J. E., Canhão, H. M., & Vaz, M. F. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025322 · Cited by 6
“05 were achieved in the power function relationship, respectively, between strength and strain rate and between stiffness and strain rate, obtained in the compression of trabecular bone [7,9].”
BackgroundCampion, C. R., & Hing, K. A. (2016) · Wiley eBooks · doi:10.1002/9781118966174.ch21 · Cited by 6
Meleshko, V. V., & Selvadurai, A. P. S. (2003) · Journal of Engineering Mathematics · doi:10.1023/a:1025045710387 · Cited by 6
New method to determine the Young’s modulus of single trabeculae
Lorenzetti, S. (2006) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-005339099 · Cited by 6
Khor, F. (2018) · UWSpace (University of Waterloo) · Cited by 7
Investigating Torque-Speed Relationship of Self-Tapping Screws
Wilkie, J., Docherty, P. D., Stieglitz, T., & Moller, K. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630356 · Cited by 5
“This is because evidence suggests minimal relationship between insertion speed and torque [8], however, these studies were done with aluminium, which appears to be less strainrate dependant than bone [9] [10].”
BackgroundGraw, C. L., Waletzko‐Hellwig, J., Saß, J., Jackszis, M., Frerich, B., Bader, R., & Dau, M. (2023) · Materials Testing · doi:10.1515/mt-2023-0004 · Cited by 5
Gefen, A., & Neulander, R. (2007) · Journal of Applied Biomechanics · doi:10.1123/jab.23.3.230 · Cited by 5
Wang, J. (1996) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
Determining relationship between bone screw insertion torque and insertion speed
Wilkie, J. A., Rauter, G., & Möller, K. (2022) · at - Automatisierungstechnik · doi:10.1515/auto-2022-0009 · Cited by 4
Biomaterials: Processing, Characterization, and Applications
Lacroix, D., & Planell, J. A. (2009) · Springer eBooks · doi:10.1007/978-0-387-84872-3_4 · Cited by 4
An Experimental and Computational Investigation of the Inelastic Behaviour of Trabecular Bone
Kelly, N. (2012) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/16244 · Cited by 4
Yang, S. (2006) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/1612 · Cited by 4
“When tested under such a low strain rate, the experiment was effectively quasi-static and the strain-rate effect on strength was not considered (Linde et al., 1991).”
BackgroundReliability and Limitations of Compression Testing of Various Biomaterials
Jokinen, V. (2017) · Tampere University of Technology Institutional Repository · Cited by 4
Gerlach, U. V., & Justus Liebig University Giessen (2002) · University writing server of the Justus Liebig University Giessen (Justus-Liebig-Universität Gießen) · doi:10.22029/jlupub-12619 · Cited by 4
Research of elasticity for a corrugated wire mesh
Choi, J., Shankar, K., & Lee, J. (2013) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2013.05.019 · Cited by 3
Ercan, B., & Webster, T. J. (2008) · CRC Press eBooks · doi:10.1201/9781420051834.sec2 · Cited by 3
Current Mechanical Test Methodologies
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2_3 · Cited by 4
Baas, J., Elmengaard, B., Jakobsen, T., Bechtold, J. E., & Søballé, K. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-009-0745-6 · Cited by 3
“The implants then were pushed out of the surrounding tissue in the direction of the implant axis at a rate of 5 mm/minute [8].”
BackgroundLacroix, D., & Planell, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-49206-9_8 · Cited by 3
Poumarat, G., & Dabonneville, M. (1992) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/bf01742445 · Cited by 3
Mechanical Behavior of Trabecular Bone
Mostakhdemin, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00003-3 · Cited by 3
Abé, H., Hayashi, K., & Sato, M. (1996) · Springer eBooks · doi:10.1007/978-4-431-65862-7_3 · Cited by 3
Análise numérica da interface osso - cimento na artroplastia da anca
Nabais, C. (2006) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/q7gd-6038 · Cited by 3
Johnson, T. P. (2005) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 3
A novel approach to finite element analysis of hip fractures due to sideways falls
Ariza, O. (2014) · cIRcle (University of British Columbia) · doi:10.14288/1.0166898 · Cited by 3
Johnston, J. D. (2010) · cIRcle (University of British Columbia) · doi:10.14288/1.0071564 · Cited by 3
Mechanical and morphometric characterization of cancellous bone
González, R. B. (2020) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/149376 · Cited by 3
A qualitative and quantitative investigation of structural morphology in the neonatal ilium
Cunningham, C. A. (2009) · Discovery Research Portal (University of Dundee) · Cited by 3
Experimental orthopedic biomechanics
Barbera, L. L., Villa, T. M. T., Innocenti, B., & Galbusera, F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824481-4.00006-8 · Cited by 2
Prot, M., Cloete, T. J., Saletti, D., & Laporte, S. (2015) · EPJ Web of Conferences · doi:10.1051/epjconf/20159403006 · Cited by 2
Charron, M., Bonnevialle, M., Autefage, M. A., & Palierne, S. (2008) · Cited by 2
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2_4 · Cited by 2
Screw fixation of implants to the spine
Patel, P. (2010) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 2
Development of Patient-Specific CT-FE Modelling of Bone Through Validation Using Porcine Femora
Emerson, N. (2012) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 2
Blecha, L. D. (2007) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-3841 · Cited by 2
“Inhomogeneity of bone was taken into account by considering a quadratic relation between elastic moduli, shear modulus and apparent density [109,154].”
Trabecular Microarchitecture, Endplate Failure, and the Biomechanics of Human Vertebral Fractures
Fields, A. J. (2010) · eScholarship (California Digital Library) · Cited by 2
Neck Response in Out of Position Rear Impact Scenarios
Shateri, H. (2012) · UWSpace (University of Waterloo) · Cited by 2
Rahman, M. M. (2006) · Dublin City University Open Access Institutional Repository (Dublin City University) · Cited by 2
Elastic Properties and Measurement Techniques of Hard Tissues
(2001) · Elsevier eBooks · doi:10.1016/b978-012445760-7/50059-9 · Cited by 2
Prot, M. (2015) · theses.fr (ABES) · doi:10.70675/a1084892z1c70z4233zb77cz230185a16af9 · Cited by 2
Loeffler, H., Saß, J., Muelders, L., Bauer, J., Friedrich, O., Bader, R., Klinder, A., & Waletzko‐Hellwig, J. (2025) · Journal of Tissue Engineering · doi:10.1177/20417314251337193 · Cited by 1
Standardization of Mechanical Experiments with Biomaterials
Parshina, I., Dol, A., Ivanov, D. V., Ченцов, А. В., Лисовенко, Д. С., & Kossovich, L. Y. (2025) · Mechanics of Solids · doi:10.1134/s0025654425604525 · Cited by 1
Prygoski, M. P., Pasang, T., Schmid, S. R., & Lozier, A. J. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4461-x · Cited by 1
“(1991) [28] was adopted (using the chosen density in fitting functions) as the yield criteria for the current study (Fig.”
MethodEstudio de convergencia por análisis de elementos finitos en tejido óseo cortical
Ruiz, N. J. G., Paredes, M. J. V., & Alvarado-Contreras, J. A. (2017) · Revista iberoamericana de ingeniería mecánica. · doi:10.5944/ribim.21.2.42357 · Cited by 1
“[32] simularon el comportamiento mecánico de una tibia humana con las correlaciones para densidades aparentes propuestas por [5] y [10] mediante TAC y el MEF.”
BackgroundRavishanker, B. B., Rao, S. K., Pai, R., Shenoy, B. S., Hegde, A., Swaroop, S., & Shetkar, A. (2019) · Multidiscipline Modeling in Materials and Structures · doi:10.1108/mmms-06-2018-0109 · Cited by 1
Theoretical Solutions of Dynamic Responses of Cancellous Bone
Wang, S., Jiang, J., & Lu, X. (2019) · Journal of Biosciences and Medicines · doi:10.4236/jbm.2019.712013 · Cited by 1
“Recently, the mechanical properties and responses were concerned because of the requirement of fracture treatment and artificial limb design [3] [4] [5].”
BackgroundProt, M., Cloete, T. J., Saletti, D., & Laporte, S. (2016) · HAL · doi:10.1016/j.jbiomech.2016.02.021get · Cited by 1
Broviak, S. (2012) · Figshare · Cited by 1
Numerical simulation of implant-bone interaction following cementless joint replacement
Starke, G. R. (1996) · Open University of Cape Town (University of Cape Town) · Cited by 1
Li, X. (2011) · uO Research (University of Ottawa) · doi:10.20381/ruor-19473 · Cited by 1
“The viscous part is responsible for the dependency of stiffness on strain rate (Carter and Hayes, 1977; Linde et al., 1991) and for phenomena such as stress relaxation and creep behaviour of spongy bone (Zilch et al.”
BackgroundBone mechanics in transplanted osteochondral grafts
Wohl, G. R. (2002) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/23399 · Cited by 1
Shirazibeheshtiha, S. (2016) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/8860 · Cited by 1
Bone mineral density and fracture risk assessment for patients undergoing total hip replacement
Pétursson, Þ. (2014) · Skemman · Cited by 1
Evolution, préparation et traitement des allogreffes de l'appareil locomoteur
Érivan, R. (2019) · theses.fr (ABES) · doi:10.70675/947ce7f7z2322z4a82zb3c6z428ad4980965 · Cited by 1
Materials & Reliability Issues in Total Hip Arthroplasty
Lenoe, E. M. (1995) · Springer eBooks · doi:10.1007/978-94-011-0157-8_8
Microdamage accumulation in bovine trabecular bone
Moore, T. L. (2001) · DSpace@MIT (Massachusetts Institute of Technology)
Sandino, C., McErlain, D. D., Schipilow, J. D., & Boyd, S. K. (2013) · Fifth Biot Conference on Poromechanics · doi:10.1061/9780784412992.132
Biomechanical Analysis of Femoral Neck Strength with Respect to Femoral Head Core Decompression
Brown, P. J. (2011) · WakeSpace Scholarship (Wake Forest University)
Metabolic Bone Disorders in the Elderly
Nagaratnam, N., Nagaratnam, K., & Cheuk, G. (2016) · Springer eBooks · doi:10.1007/978-3-319-25787-7_10
The Effects of Impact Loading on the Equine Metacarpophalangeal Joint
McCarty, C. A. (2014) · The Atrium (University of Guelph)
Quantifying the response of vertebral bodies to compressive loading using digital image correlation
Gustafson, H. M. (2016) · cIRcle (University of British Columbia) · doi:10.14288/1.0319083
“performed with a modified method in terms of the cylinder dimensions and bone constraint [72].”
BackgroundMethodNon-linear anisotropic mechanical behaviour of hard and soft tissues
Nolan, D. R. (2015) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17189
The application of the homogenisation method to the numerical modelling of cancellous bone
Conway, D. J. (1995) · Open University of Cape Town (University of Cape Town)
Multiscale characterization of mechanical and fracture properties of cortical bone specimens
Mendu, K. (2017) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Monotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
Inteligentní řídící metody v automatizaci procesů řízení stavebních strojů
Vaverka, M. (2010) · Brno University of Technology Digital Library (Brno University of Technology)
Untersuchung zur Bestimmung der Knochendichte in der zahnärztlichen Implantologie
Oeßelmann, N. (2010) · OPUS FAU (Kooperativer Bibliotheksverbund Berlin-Brandenburg (KOBV), on behalf of the Universitätsbibliothek Erlangen-Nürnberg)
Beagley, A., Richards, H., & Giles, J. W. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2309.01769
Metadata
- Authors
- Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K.
- Affiliations
- Aarhus University Hospital (DK)
- ORCID
- Odgaard, Anders
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 24
- Issue
- 9
- Pages
- 803-809
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2143367764
- Semantic Scholar
- 72af2a7e4a64ff6fc5f5338e1d8643c10f9addaa
- Cited by
- 171
- References
- 41
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 3 · 2020: 9 · 2019: 9 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 6
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, strain rate, apparent density, stiffness, ultimate strength, ultimate strain, uniaxial compression, power function relationship, proximal tibia
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Epiphyses, Humans, Knee Joint, Male, Tensile Strength, Tibia, Bone Density, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.